XSDC 601-02
3. Start-Up
3.1 Handling with hoisting gear
Ensure to lift the device by means of fork lifts or with secured harnesses. Do not use pipe connections
or other attachment parts as lifting points.
3.2 Installation
With respect to the device's installation, please adhere to the following:
✓
Do not expose the device to weather.
✓
Ensure the intended installation site to be plane and capable of carrying the devices operating
weight. The device does not require foundation.
✓
Provide for a clearance of at least the device's width (in height) for repair and
maintenance/servicing works at the operating side and the inspection lids, in particular at the
rotor.
✓
devices may not be mounted in and/or exposed to the intake of liquids, e.g. filled tanks or
sumps, flooded installation sites etc.
✓
Operation in and/or with potentially explosive ambience is not permissible.
3.3 Startup
Prior to initial operation, ensure to check all mechanical and electrical connections for secureness
and leak-tightness. Also remove possible soiling.
The device has been designed for a supply voltage of 230 Volts / 50 Hz, and may exclusively be
operated with the respective voltage.
Connect the plug to a safety socket. If the device does not immediately start automatically, it is in
standby mode. In that case, please press the [ON]-button in order to activate the device.
The cabinet's initializer will then start. As soon as initialization has been completed, the main menu
will appear on the display, and the cooling module will start. Following initialization, the program will
start with indication of the temperature of the cabinet's interior. The (optional) red/green signal light
will indicate the different states and alarm functions. Alarms are indicated with a flashing red signal.
The preset temperature will be reached after approximately 30 minutes. After the preset value has
been reached the temperature will stay at the preset level.
The cabinet is enabled immediately after start-up; its full performance will be achieved after approx.
24 hours.
In order to switch off the device, please press the [ON]-button during the cooling operation, located
on the external display. Keep the pushbutton pressed for 3 seconds. This power-off function will
switch the device to idle mode, and deactivate all control outputs and display functions. However, the
device itself will remain switched on. Consequently, please always disconnect the device from the
mains connection if maintenance/servicing activities are performed.
Содержание Super Dry Totech XSDC 601-02
Страница 1: ...XSDC 601 02 Operation manual XSDC 601 02 ...