Asycube - Asyril SA
Operating Manual
©
Copyright Asyril S.A.
Description
v1.7
FO 32.03.118
Operating Manual
Asycube
- Asyril SA
20/41
Connecting RS-
232 “AsyLink”
2.4.2.2.
NOTE :
When the Asycube is configured in RS-232 mode, the address node has to be set at value
“0”. Otherwise the Asycube will not work.
Figure 2.12: Asylink RS-232 scheme
XS202 (.)
Signal
Description
XS202 (1) GND
This common signal is
a dedicated return to
internal
system
ground.
All
serial
communication should
be referenced to this
pin.
XS202 (2) RXD
This input signal is
used to receive data
according to RS-232
protocol
XS202 (3) TXD
This output signal is
used to transmit data
according to RS-232
protocol.
XS202 (4) VCC
This signal is not used
Figure 2-13 : Asylink (RS 232) interface
XS202 (4)
XS202 (1)
AsyCube RS232 Cable
XS 202
– Type HARTING MINI 3.81 4PF
Host Computer
RS232 sub-D 9poles
CTS - 8
RTS - 7
TXD - 3
RXD - 2
DSR - 6
DTR - 4
DCD - 1
GND - 5
TXD
– XS202(3)
RXD
– XS202(2)
GND
– XS202(1)
Содержание Asycube
Страница 2: ......