Asycube 380 & 530
Operating Manual
000.101.151
Version: B
46
/
50
Asycube 380
Step 1
Disconnect the power cable
(A) (or switch off the power
supply to the Asycube)
Step 2
Insert a tip in the “Reset IP”
hole (B) and reconnect the
power cable or switch on the
Asycube.
The Asycube will load the
following default parameters
at start-up:
IP: 192.168.127.254
SubnetMask: 255.255.255.0
TCP port: 4001
Step 3
Parameters in the memory can now be modified (by direct access via Asycube
commands, by functions in dll or by Asycube configuration page in HMI (see relative
documentation for more detail).
(A)
(B)