Asycube 380 & 530
Operating Manual
000.101.151
Version: B
45
/
50
Asycube 530
Step 1
Disconnect the power cable
(A) (or switch off the power
supply to the Asycube)
Step 2
Press and hold the
“Reset
IP” (B) button whilst you
reconnect the power cable or
you switch on the Asycube.
The Asycube will load the
following default parameters
at start-up:
IP: 192.168.127.254
SubnetMask: 255.255.255.0
TCP port: 4001
Step 3
Parameters in the memory can now be modified (by direct access via Asycube
commands, by functions in dll or by Asycube configuration page in HMI (see relative
documentation for more detail).
(A)
(B)
Содержание Asycube 380
Страница 29: ...Asycube 380 530 Operating Manual 000 101 151 Version B 29 50 15 L hopper mechanical interface for Asycube 530 ...
Страница 48: ...Asycube 380 530 Operating Manual 000 101 151 Version B 48 50 5 Annexes CE certificate ...
Страница 49: ...Asycube 380 530 Operating Manual 000 101 151 Version B 49 50 ...