ASUS Vintage V2-PE3
5-23
5.9
Other items
Load Optimized Defaults
Allows you to load the optimized defaults.
Supervisor Password
Allows you to set the supervisor password. To set a password, press
<Enter>. Type in and confirm the password when prompted.
User Password
Allows you to set a user password for access to system after boot-up.
Save & Exit Setup
Once you are finished making your selections, choose this option to ensure
that the values you selected are saved to the CMOS RAM. When you select
this option, a confirmation window appears. Select Yes to save changes and
exit.
Exit Without Saving
Select this option only if you do not want to save the changes that you
made to the Setup program.
Start Up Temperature (ºC) [50]
Allows you to set the fan start-up temperature.
Configuration options: [0] [1] ~ [100]
Full Speed Temperature (ºC) [70]
Allows you to set the threshold temperature before the fan begins running
at full speed. Configuration options: [0] [1] ~ [100]
Start Up PWM [60]
Sets the start-up Pulse Width Modulation (PWM) value when the fan starts
running. Configuration options: [0] [1] ~ [127]
Slope Select PWM/ºC [4 PWM/ºC]
Sets the PWM increase value per degree Celcius to control the fan speed
when the system temperature increases.
Configuration options: [0 PWM/ºC] [1 PWM/ºC] [2 PWM/ºC] [4 PWM/ºC]
[8 PWM/ºC] [16 PWM/ºC] [32 PWM/ºC] [64 PWM/ºC]