6-20
Chapter 6: RAID Configuration
Using the Objects command
To check data consistency using the
Objects
command
1.
From the
Management Menu
, select
Objects
, and then select
Virtual Drive
from the
sub-menu.
2.
Use the arrow keys to select the virtual drive you want to check, and then press
<Enter>.
3.
Select
Check Consistency
from the pop-up menu, and then press <Enter>.
4.
When prompted, use the arrow keys to select
Yes
from the dialog box to check the
drive.
5.
When checking is complete, press any key to continue.