2-29
ASUS TS500-E5
2.9.3
Power supply unit
The system is compatible with both EPS 12 V 670 W single power supply and 650 W
redundant power supply. Purchase based on your needs.
You MUST disconnect all power cable plugs from the motherboard and other
installed devices before removing the power supply unit.
Installing the single power supply unit
1. Align the single power supply unit
(PSU) in the chassis with the four
mounting screw holes.
2. Make the PSU sit on the shelf ledge
when fastening it to the chassis with
screws.
3. Fasten the two screws on the
chassis wall.
Installing the redundant power supply module
1. Unscrew and remove the power supply brackets at the back and on the
chassis wall.
2. Screw the metal bracket from the
chassis wall to the redundant power
supply cage.