6-26
Chapter 6: RAID configuration
3. When prompted, use the arrow keys to select
Yes
from the
Consistency
Check
dialog box, then press <Enter>. You may also press <F10> to check
the drive consistency.
A progress bar appears on screen.
4. While checking the disk consistency, press <Esc> to display the following
options.
• Stop
- Stops the consistency check. The utility stores the
percentage of disk checked, When you restart checking, it
continues from the last percentage completed rather than
from zero percent.
• Continue
- Continues the consistency check.
• Abort
- Aborts the consistency check. When you restart checking, it
continues from zero percent.
5. When checking is complete, press any key to continue.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Logical Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Logical Drives
Loical Drive 0
Consistency Check?
Yes
No
Select VD
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Logical Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Logical Drives
Loical Drive 0
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
¦
85 % Completed
The Data On The Drives Is Inconsistency. Repair Done!
Содержание TS500-E5
Страница 1: ...Pedestal 5U Rackmount Server TS500 E5 User Guide ...