256
2.147
LEDID4 [24H 2BH]: EDID readout
Function:
This command reads the EDID from the monitor via the VG generator.
Sequence: Type 3
Command:
STX
1 byte
02H
VG4CMD
1 byte
FDH
LEDID4
2 bytes
24H 2BH
Block No.
1 to 3 bytes
“0” to “255”
ETX
1 byte
03H
Fig. 2-147-1
Data:
STX
1 byte
02H
TRDT
1 byte
10H
EDID
256 bytes
“00” to “FF” (Hexadecimal format, 2 bytes × 128)
ETX
1 byte
03H
Fig. 2-147-2