Chapter 2 INDIVIDUAL FORMATS FOR VG CONTROL COMMANDS
245
2.137
INDC4 [24H 21H]: Program No. incrementing /
decrementing
Function:
This command increments or decrements the program number (or timing or
pattern number), and executes the program.
Sequence: Type 2
Command:
STX
1 byte
02H
VG4CMD
1 byte
FDH
INDC4
2 bytes
24H 21H
[+]/[-]
1 byte
“0” = [+], “1” = [-]
ETX
1 byte
03H
Fig. 2-137-1
* This command increments or decrements the numbers on the basis of the current
status of the VG generator.
Example 1: When the VG generator is in the internal timing data execution status
(Category: All)
→ Internal timing data numbers 1001 to 2000 are subject to incrementing
or decrementing.
Example 2: When the VG generator is in the user data (CompactFlash card or
internal flash memory) execution status (Category: All)
→ User data numbers 1 to 1000 are subject to incrementing or
decrementing.
Example 3: When the VG generator is in the internal timing data execution status
(Category: VESA)
→ Internal timing data numbers 1001 to 2000 for which VESA has been
set as the categories are subject to incrementing or decrementing.
Содержание VG-870
Страница 2: ......
Страница 4: ......
Страница 30: ...16 ...
Страница 53: ...Chapter 2 INDIVIDUAL FORMATS FOR VG CONTROL COMMANDS 39 27 28 29 DOTS 30 CROSS 31 CHARA Fig 2 11 2 ...
Страница 188: ...174 Dir 1 byte 0 Left 1 Right 2 Up 3 Down 4 Top left 5 Bottom left 6 Top right 7 Bottom right ETX 1 byte 03H Fig 2 89 2 ...
Страница 280: ...266 Subtitle pattern stepV4 1 to 3 bytes 0 to 255 ETX 1 BYTE 03H Fig 2 154 1 ...
Страница 310: ...296 ...
Страница 352: ...338 ...
Страница 436: ...422 ...
Страница 474: ...460 ...