![ASTRO V16 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/astro/v16/v16_instruction-manual_2990994012.webp)
8 Technical specifications and accessories
12
VSN 1
VSN 2
V 16 + VSN
VSN 1 power supply / VSN 2 redundant power supply
power supply plug-in unit
Technical enhancements, design modifications, and errors reserved.
V16 technical specifications
SAT processing, base unit without cards
XF… internal jumper cable
XF-450
V16 Base unit
Supply voltage
[V~/Hz] 230 / 50
EMC
EN 50083 Pt 2 / A1 compliant
Permitted ambient temp.
[°C]
0 … +50
Housing (H x W x D)
[mm]
without mounting bracket
340 x 426 x 277 (19” / 7 HE Basis)
with front side mounting bracket
340 x 491 x 277
with rear mounting bracket
340 x 491 x 290
+ 3 HE for air flow unit
Weight of V16.1 base unit
[kg]
9,6
Type
VSN 1
single power supply
VSN 2
dual power supply
Order no.
350 210
350 220
Rated voltage
[V~] 230, (+6/-10%) 50/60 Hz
230, (+6/-10%) 50/60 Hz
Power input
[VA/W] 196/190
208/200
Power output
5 V/13,5 A, 12 V/6,5 A, 28 V/200 mA
Mains Fuse
T 1,25 A “L”, IEC60127-2/3
Type
XF-450
XF-700
Order no.
790 450
790 700
Length
[mm] 450
700
Shielding
[dB]
> 90
Connections
[Ω]
75, F-connector