background image

U

 

124 16-programme IP / FM converter

U 100 Base unit 

Operating instructions

Содержание U 100

Страница 1: ...U 124 16 programme IP FM converter U 100 Base unit Operating instructions...

Страница 2: ...ected by copyright This manual may not be reproduced in any form not even in part without prior written permission from the ASTRO company Pictograms and safety instructions Pictograms are visual symbo...

Страница 3: ...124 to a PC laptop 9 3 2 The Web browser user interface 9 4 Login 10 5 Status 11 6 Setting the IP interfaces IP management and base device 12 6 1 Configuration of the IP interfaces 13 6 2 IP managemen...

Страница 4: ...heel menu switch Display of management IP addresses data IP addresses status messages etc Status display Status display for slots L left M middle R right P power supply Data ports HF outputs Fan Manag...

Страница 5: ...ay only be repaired by sending it to ASTRO along with a precise description of the error Displays indicate the status of the device operation as well as the existence of DC voltages separate from the...

Страница 6: ...can be performed by appro priately instructed service personnel Removal and installation of signal converters e g U 124 and power units also in the operating mode of the U 100 Replacing power units Af...

Страница 7: ...ignal converter is located on the backplane 2 8 1 Coding the backplane To correctly define the position of the backplane and thus the position of the related signal con verter in the U 100 base device...

Страница 8: ...blind panel The cables now visible must be connected to the backplane coded according to chapter 2 8 1 as shown in the following figure Figure 3 Connecting the voltage supply and signal lines The back...

Страница 9: ...ation about the U 124 This information is as follows SW 4021 indicates the software level of the U 124 EdgePAL FW 1 2 is the level of the firmware in the U 124 EdgePAL HW 1 is the hardware version of...

Страница 10: ...User admin or user Password astro After correctly entering the login data you can proceed with the configuration Note For security reasons the user names and passwords should be changed from the state...

Страница 11: ...gure 3 Status display in the Status submenu Ethernet status Status display of the IP receivers Memory status Status display of the FM output programme Display of diverse status messages on the module...

Страница 12: ...r 12 6 Settings for the IP interfaces IP management and base device When you click on the Main submenu in the left frame the following window appears example Figure 4 Overall view The settings availab...

Страница 13: ...e 5 IP interface configuration Changes to the IP addresses must be transferred to the U 124 using the Submit button Note When programming the IP addresses make sure the addresses are not already alloc...

Страница 14: ...nfiguration of the U 124 is always written to the device using the Submit buttons and is therefore activated immediately If you want to save the current status you press the Save 2nd button This curre...

Страница 15: ...ura tion is displayed You go to the detailed settings either by clicking the relevant channel e g IP RX3 or clicking the relevant submenu in the left frame Figure 10 Detailed settings of the IP receiv...

Страница 16: ...e Port line the data interface is selected A or B and the preferred data interface is set This function enables the U 124 to switch to the second interface after an input signal has failed and to swit...

Страница 17: ...data flow Changes must be written to the device by pressing the Submit button Figure 13 Overview of the HF parameters If you select the option On in the Reference column then the level set in the mod...

Страница 18: ...f the data are available in TS and if the option dynamic off Service name is selected the PS data will also be transmitted If static is selected you have the option of entering 8 blocks of 8 character...

Страница 19: ...adjust the tone control Line Radio text Transmits if provided by the sender the radio text If static is configured and a text entered this will be transmitted until radio text is dynamically transmit...

Страница 20: ...the user names and passwords should be changed from the state on deliv ery This prevents unauthorized access In the Timeout line the minutes are entered until the U 124 automatically logs the user out...

Страница 21: ...e as regards the services tables it contains When an analysis has been started it can take several minutes to complete In particular the analysis of the EIT Event Information Table can take somewhat l...

Страница 22: ...ces you must enter the MAC address of the device You will find the MAC address on the Web browser interface in the Licensing submenu HWID After the MAC address is passed on the licence keys are genera...

Страница 23: ...not necessary to enter the user name and the password Under Path you must enter the path under which the U 124 software for the update was stored You must ensure that the software is stored in the pa...

Страница 24: ...Figure 22 Settings for the tftpd32 TFTP programme To start the update the IP address of the local computer must be entered as the server address in the line T FTP Server address Figure 23 and the pro...

Страница 25: ...g Figure 23 System log settings The SNMP MIBs available are stored on the U 124 and can be downloaded from the device The operations in the system log are sorted by the time they occurred To delete th...

Страница 26: ...26 14 Statistics Clicking on the Statistics submenu takes you to the statistics for the data transfer of the U 124 Here all the statistics relevant to the operation of the device and its analysis are...

Страница 27: ...ork properties You reach the network properties by clicking the Network Monitor submenu The properties displayed are purely for information purposes and are used to describe the network Figure 25 Exam...

Страница 28: ...hen you are logged in takes you to the logout of the U 124 Figure 26 Logging out of the U 124 If you confirm the request by clicking Yes you are logged out No further settings can be made without logg...

Страница 29: ...0 45 Type U 124 Order number 380 124 Network interfaces forwarded passively to U 1xx Management 2 x 100 Base T Ethernet RJ 45 Data 2 x 1000 Base T Ethernet RJ 45 Protocol IEEE802 3 Ethernet RTP ARP IP...

Страница 30: ...30 Operating Manual U 124 16 programme IP FM converter 30...

Страница 31: ...31 Operating Manual U 124 16 programme IP FM converter 31...

Страница 32: ...U 124 16 programme IP FM converter ASTRO Strobel Kommunikationssysteme GmbH Olefant 1 3 D 51427 Bergisch Gladbach Bensberg Tel 02204 405 0 Fax 02204 405 10 eMail kontakt astro kom de www astro kom de...