2                                               2-11-93 TI648-93-0    

1. The tool must be in the fully open position as 

shown in figure #2. 

 

Movable Die

 

Figure # 2 

 
2. Locate the Movable Pop-in Die and insert the 

die post into the die nest. Note the off-center die 
post. The Movable Pop-in Die can only be inserted 
in one direction. See figure # 2 

 
NOTE: The Movable Pop-in Die must be installed 

first. 

 
3. Locate the Stationary Pop-in Die and engage the 

flat end of the Die with the housing cleat. Rotate the 
die in a clock-wise direction to engage it with the 
Stationary Die Retaining Detent, see figure #3. 
Observe that the Stationary Pop-in Die is installed 
parallel to the side plates and that it is not skewed in 
any way. 

 

Stationary Die
Retaining Detent

 

Figure #3 

 
 

CAUTION: 

 VERIFY THAT THE STATIONARY DIE IS 

INSTALLED CORRECTLY. IMPROPER 
INSTALLATION WILL RESULT IN DAMAGE 
TO THE TOOL OR THE DIE SET.  

 
4. Cycle the tool to set the die.  
 

 

 

 

 

d. Crimping Operation 

1. The tool  must be in the fully open position. 

Insert the prepared connector through the tool 
opening and place in the appropriate cavity. For RF 
connector fittings use the die face as a locational 
stop. For shield terminations locate the crimp by eye.  

 
2.  Squeeze  the handles together until the positive 

stop is reached. The tool will release and return to 
the fully open position.  

 
3. Remove the crimped termination. 
 

e. Die Removal 

1. The tool must be in the fully open position. 
 
2. To remove the Stationary Pop-in Die, locate the 

DRT7. Insert the DRT7 into the hole in the top of 
the tool,  as shown in figure #4, and tap lightly on 
the end indicated. The Stationary Pop-in Die will 
drop from the tool. 

 
NOTE: Always remove the Stationary Pop-in Die 

First. 

 
 

DRT7

DRT7

Figure #4 

 
3. To remove the Movable Pop-in Die, position the 

DRT7 as shown in figure #4, and tap upward lightly 
to release the die. 

 

f. Tool Calibration 

1. The hand pressure required to cycle the tool 

with a set of dies in it should be set at 20-50 lb. 
Astro has the AT903 spring tester available for this 
purpose. 

 
 

Adjustment Screw

 