![Astro Metal PACIFIC FIRE LIGHTER MK II Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/astro-metal/pacific-fire-lighter-mk-ii/pacific-fire-lighter-mk-ii_instruction-and-safety-manual_2991092004.webp)
5. RE-FUELING THE PACIFIC FIRE LIGHTER
A recently used Pacific Fire Lighter must be extinguished and allowed to cool down
for at least one minute prior to refueling. Check that the wick is out and cool. All
refueling is to be carried out in a safe outdoor location, well away from sparks,
flames and embers. Keep clear of al electrical equipment or internal combustion
engines that could cause a spark. Be aware to keep away from a source of wind
blown embers. Do not smoke.
The Pacific Fire Lighter must be in direct contact with the ground when refueling.
Do not refuel the Pacific Fire Lighter on the tray of a transport vehicle. Wear
gloves and safety glasses if fuel could be splashed. Take care to prevent fuel spills.
Place fuel container on the ground before opening. If a hose is to be used for a
large container, the nozzle must be in contact with the fuel tank of the Pacific Fire
Lighter before dispensing commences.
A large rag will soak up spilt fuel and keep components clean. Place the rag on
level ground and set the Pacific Fire Lighter on it in an upright position, well away
(3m) from dry vegetation or dry forest litter. Unscrew the filler bung and place in
the rag to keep it clean, and commence refueling, using a funnel with strainer
fitted. Carefully decant the correct fuel mixture from a bulk container, avoid
overfilling and allow for expansion by leaving (3cm) below the thread for the filler
bung. Wipe the outer surface and handle of the Pacific Fire Lighter with a piece of
rag to ensure it is clean and dry. Firmly reseal the bulk container after refilling is
complete, (where a hose is used, replace the hose to its storage position n the bulk
fuel container).
6. CHECKS TO BE MADE PRIOR TO LIGHTING PACIFIC FIRE
LIGHTER
Ensure the outer surface of the Pacific Fire Lighter is clean and dry and handle is
clean and dry. Check for leaks and do not light a torch if a leak is evident. Move
well clear of refueling location or opened fuel containers. Check wick casing to
ensure it is clean from ash, carbon or other foreign matter.
7. LIGHTING AND EXTINGUISHING
In an area where Pacific Fire Lighter is to be used, point nozzle to the ground at
approximately 30 to 35 degrees, open valve at the base of the wand, allowing fuel
to run onto the wick then onto litter or vegetation on the ground. Ignite fuel and
dampened litter or vegetation with a match. Apply the wick to this small fire to
light the Pacific Fire Lighter.
To relight the Pacific Fire Lighter during use (with nozzle pointing downwards and
fuel dribbles over the wick) place the wick over a fire. To extinguish a Pacific Fire
Lighter, smother the wick in loose earth, or leave it standing upright and the wick
will burn dry.
8. OPERATING THE PACIFIC FIRE LIGHTER
Ensure sufficient fuel for carrying out a burning operation is on hand in containers
readily available for refueling torches as required. Carry the torch to the area
Pacific Fire Lighter MKII
Instruction and Safety Manual
!
4