IMPORTANT! GENERAL SAFETY 
PRECAUTIONS. READ AND 
UNDERSTAND THESE SAFETY 
RULES BEFORE YOUR FIRST FIRE.

       WARNING 

To avoid the risk of damaging 
fi replace materials and increas-
ing the risk of fi re, do not use the 
fi replace to cook or warm food.

       WARNING 

Never leave children unattended 
when there is a fi re burning in 
the fi replace.

       WARNING 

NEVER use gasoline, gasoline-
type lantern fuel, kerosene, 
charcoal lighter fl uid, naphtha, 
engine oil or similar liquids to 
start or “freshen up” a fi re in this 
fi replace. Keep any fl ammable 
liquids a safe distance from the 
fi replace at all times. 

       WARNING 

Use care when selecting window 
treatments for windows located 
near the fi replace.  Avoid using 
combustible flowing window 
treatments such as curtains 
on nearby windows that are of 
suffi cient length to be blown in 
front of an open fl ame when the 
window is opened.

Keep any combustible furniture, 
materials or decorative pillows 
at least 48" (1219 mm) from the 
front fi replace opening.

       WARNING 

Never leave your fi replace unat-
tended while it is burning.

       WARNING 

Be careful adding wood fuel to the 
fi re or handling fi replace tools such 
as shovels, tongs or pokers.

       WARNING 

The bottom refractory can be 
cracked by excessive abuse such 
as tossing heavy logs onto the 
grate or gouging with fi replace 
tools. Exercise caution when 
adding wood to your fi replace.

       WARNING 

Always ensure that the air inlet to 
the fi replace is free from debris 
and any other obstructions that 
can block the entrance of air.

       WARNING 

Neither the manufacturer nor the 
seller warrants “smoke free” 
operation nor are we responsible 
for inadequate system draft 
caused by mechanical systems, 
general construction conditions, 
inadequate chimney heights, 
adverse wind conditions and/or 
unusual environmental factors or 
conditions beyond our control. 

    

  WARNING

The Villa Vista™ fi replace must 
be installed with an outside air 
kit intake, which is included with 
the fi replace

  WARNING

THE FIREPLACE MUST BE OPER-
ATED WITH THE DOORS FULLY 
OPENED OR DOORS FULLY CLOSED. 
IF THE DOORS ARE LEFT PARTLY 
OPENED, GAS AND FLAME MAY BE 
DRAWN OUT OF THE FIREPLACE 
OPENING, CREATING RISKS OF 
BOTH FIRE AND SMOKE.  IF THE 
UNIT IS OPERATED WITH THE 
DOORS FULLY OPENED, THE FIRE 
SCREEN MUST BE USED. 

 

  WARNING

THIS FIREPLACE HAS NOT BEEN 
TESTED WITH AN UNVENTED 
GAS   OR A FIREPLACE INSERT.  
TO REDUCE RISK OF FIRE OR 
INJURY, DO NOT INSTALL AN 
UNVENTED GAS LOG SET OR 
FIREPLACE INSERT OR OTHER 
PRODUCTS NOT SPECIFIED FOR 
USE WITH THIS FIREPLACE.

       IMPORTANT 

When burning wood, use SOLID 
NATURAL  DRY WELL-SEASONED 
WOOD ONLY.  Hardwoods are rec-
ommended (soft woods tend to burn 
very quickly).  

• 

 

DO NOT burn treated wood, 
charcoal, coal, trash, card-
board, driftwood, woods dipped 
in tar, Christmas tree greens, 
pitch, pine tar, creosote, chemi-
cal chimney cleaners, fl ame 
colorants, polystyrene packag-
ing, wood products with syn-
thetic binders (i.e. plywood).  
Plywood, lumber and other 
misc. materials can produce 
abnormally high temperatures, 
sputtering and smoking fi res 
and may contain hazardous 
chemicals to treat insects and 
fungus.

• 

 

Burning unapproved fuels can 
produce excessive tempera-
tures, beyond the design capa-
bilities of the fi replace and may 
produce excess sparks or may 
contain hazardous chemicals.  
Burning unapproved fuels can 
result in a chimney fi re, a house 
fi re, personal injury, death or 
loss of property.

 

  WARNING

Never modify or alter your fi re-
place system in any way. To do 
so may create a potential fi re 
hazard and void the limited war-
ranty, listings and approvals of 
this system.

Содержание VILLA VISTA

Страница 1: ...justable safety gate or barrier screen A French manual is available upon request Order P N 900136 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi...

Страница 2: ...uctionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING The Villa Vista fireplace must be installed with an outsi...

Страница 3: ...ACBI Chimney Installation Instructions Page 19 Offset Chimney Installation Page 20 Angled Wall Radiation Shield Page 21 Chimney Support Installation Page 22 Chimney Chase And Multiple Terminations Pa...

Страница 4: ...ng the combustor have to be higher than 500 F 260 C That is why the unit is equipped with a by pass damper that allows the draft air to by pass the catalytic combustor Opening the by pass damper contr...

Страница 5: ...ndonmanyfactors includingchimney length and the moisture content of the wood This method of burning should be used only after operating the Villa Vista fireplace with the aircontrolopenedtoproduceahot...

Страница 6: ...including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulations to operate wood heaters in a man...

Страница 7: ...roper operation will prevent chimneyfires Keepyourchimneyclean Donot allow more than 1 16 creosote build up in your chimney The amount of creosote will depend on variables such as frequency of use and...

Страница 8: ...after a hot fire has been started Burn hardwoods Masking Soot See Photo 8 Combustor has not maintained a light off Burning coal will cause a sulfur based compound to coat the catalyst Place combustor...

Страница 9: ...e Do not use abrasives such as steel wool or steel pads for they may scratch the door frame finish Ashes Whenever ashes get 3 to 4 inches deep in your firebox andwhenthefirehasburneddownand cooled rem...

Страница 10: ...door using the hinge screws see Figure 9 Figure 8 HINGE SCREWS GASKET ADJUSTEMENT SCREW DOOR HINGE SCREWS Figure 9 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO P...

Страница 11: ...nts The Villa Vista fireplace may be installed directly on a combustible floor The supplied safety metal strip must be positioned as fol lows One half under the front of the fireplace and the other ha...

Страница 12: ...llustrations and photographs are nottoscale consultinstallationinstructions Product designs materials dimensions specifications colorsandpricesaresubjectto change or discontinuance without notice Allf...

Страница 13: ...bustibles around chimney components required NOTE Blown or fill type insulation materials must not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcod...

Страница 14: ...he unit 38 and a height of 54 from the base of the appliance see Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Fig...

Страница 15: ...mum length See Figure 17 The height of the louver must be measured from the base of the Villa Vista fireplace to the middle point of the louver When installing the double outlet system the hotairoutle...

Страница 16: ...ral heating system Malfunction of the heating system s fan will cause the furnace duct to overheat A furnace duct is only single wall and not double wall as is required for the Villa Vista fireplace h...

Страница 17: ...basement or garage 4 The air intake register should be installed where it is not likely to be blocked by snow or exposed to extreme wind and well away fromautomobileexhaustfumes gasmeters and other ve...

Страница 18: ...ity Chimneys International Ltd 7 diameter chimney systems models ACBI or ASHT or S2100 or DuraVent model DuraTech DTC chimney systems NOTE Use of ACBI chimney with these fireplaces require the use of...

Страница 19: ...stallauniversalsupportfasteningthestrapsto thesurroundingjoists ASHT Installsupport as required see Chimney Support Installation Section on Page 22 4 Puttheroofflashinginplaceandsealthejoint between t...

Страница 20: ...45mm 19 483mm 21 3 8 545mm CrossSlopeHoleSize Putthechimneycapintoplace Washtheroofflashingwithasolvent or vinegar thenpaintitwithrust proof paint Table 2 1 Install the first elbow Turn it in the requ...

Страница 21: ...TC 15 Deviation 3 5 16 84 mm 4 5 16 110 mm 5 7 8 149 mm 7 7 16 189 mm 10 1 2 268 mm 13 5 8 346 mm 15 3 8 391 mm 16 7 16 418 mm 18 457 mm 19 1 2 495 mm 22 5 8 575 mm Length 15 11 16 398 mm 19 9 16 497...

Страница 22: ...ightly lift the chim neysystemsotheweightwilllieonthesupport notonthefireplacetoreduceexpansionnoises This support has two possible uses 1 For ASHT it must be used on a roof to support the chimney 2 I...

Страница 23: ...SHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimn...

Страница 24: ...r Chimney for Relining Masonry Chimneys Tubinox chimney or Projet SS 7 diameter with adaptor for installation in a masonry chimney NOTES Projet Nova Temp HT6000 is equivalent to S2100 Projet Nova Temp...

Страница 25: ...o flexible pipe adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2 clamps BISAF BISAF Thermopile gauge and label replacement J8004 CLEARANCE TO COMBUSTIBLES The followi...

Страница 26: ...orts Support Section 10 long ACBI7SL ACBI7SL Universal Support AC10SU AC10SU Roof Flashings 1 12 7 12 5 30 Adjustable ACBI7FAR ACBI7FAR 8 12 12 12 30 45 Adjustable ACBI7FBR ACBI7FBR Flat Roof Flashing...

Страница 27: ...r ordering information DuraTech DTC 1 High Temp Insulated Stainless Steel Chimney 7 I D and 11 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT and CAN ULC S629 Description Part Cat No Len...

Страница 28: ...ney Adaptor 45 BISPMA CANADA ONLY BISPMA 30 Adaptor for Masonry Chimney BISPMA30 BISPMA30 SECURITY CHIMNEYS PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimney...

Страница 29: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 30: ...CEMENT PARTS See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be...