NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

22

*

Available from Security Chimneys™ 

CHIMNEY CHASE AND MULTIPLE TERMINA-
TIONS

For the purpose of this manual, a chimney chase 
is considered a part of the chimney system 
rather than part of a building.  The termination 
must be placed a minimum of 18" (460 mm) 
above the chase.

For installations where more than one chimney 
is located in the same chase or within the same 
area, we suggest that their terminations be 
separated by at least 16" (410 mm) horizontally, 
and 18" (460 mm) vertically.  This separation is 
to prevent smoke migration from one chimney 
to another (

see 

Figure 29

)

.

CHIMNEY ADAPTOR

*

 (S2100+)

The fi replace is normally supplied with a chimney 
adaptor suitable for the ASHT+

*

 chimney.  If you 

want to install a S2100+

*

 chimney, an adaptor is 

availible (7UCA

*

) (

see 

Figure 30

)

.  If installing 

ACBI, adaptor H3805

*

 (ACBI7SBA

*

) or offset 

adaptor H3806

*

 (ACBISBA30

*

) is required.

Figure 29

18" (460mm)

16"

16"

18" (460mm)

18" (460mm)

(410mm)

(410mm)

CHIMNEY SUPPORT INSTALLATION

Universal Roof Support

When installing a support, slightly lift the chim-
ney system so the weight will lie on the support, 
not on the fi replace to reduce expansion noises. 

This support has two possible uses:

1.

 For 

ASHT+

*

 it must be used on a roof to 

support the chimney.

2.

  It may be used on a fl oor, ceiling or roof 

above an offset to support the chimney 
above the offset.

3.

  It may be used on a fl oor, ceiling or roof 

above as a supplementary support when 
the chimney height exceeds 15 feet (4.6 
m).

Table 6

  gives maximum height of supported 

chimney.

Figure 30

NOTE: 

 For the ACBI

*

 chimney, a universal sec-

tion must be used every 20 feet (6 m) instead 
of the universal roof support (ST

*

).

For roof support installation, refer to the instruc-
tions provided with the support.

Universal Offset Support

This support is used to support the chimney 
above an offset.  Or it may be used on the wall 
to support the chimney.  The maximum heights 
are given in 

Table 6

.  For offset support instal-

lation, refer to the instructions provided with 
the support. 

CHIMNEY MODEL

MAXIMUM HEIGHT OF SUPPORTED CHIMNEY

Offset Support

Roof Support

ACBI 

*

40 feet (12.91m)

50 feet (15.02m)

ASHT+ 

*

24 feet (8.54m)

27 feet (8.84m)

DuraTech DTC 

**

24 feet (8.54m)

27 feet (8.84m)

S2100+ 

*

16 feet (5.42m)

18 feet (6.10m)

Table 6

**

Available from DuraVent

®

Содержание VILLA VISTA

Страница 1: ...justable safety gate or barrier screen A French manual is available upon request Order P N 900136 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi...

Страница 2: ...uctionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING The Villa Vista fireplace must be installed with an outsi...

Страница 3: ...ACBI Chimney Installation Instructions Page 19 Offset Chimney Installation Page 20 Angled Wall Radiation Shield Page 21 Chimney Support Installation Page 22 Chimney Chase And Multiple Terminations Pa...

Страница 4: ...ng the combustor have to be higher than 500 F 260 C That is why the unit is equipped with a by pass damper that allows the draft air to by pass the catalytic combustor Opening the by pass damper contr...

Страница 5: ...ndonmanyfactors includingchimney length and the moisture content of the wood This method of burning should be used only after operating the Villa Vista fireplace with the aircontrolopenedtoproduceahot...

Страница 6: ...including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulations to operate wood heaters in a man...

Страница 7: ...roper operation will prevent chimneyfires Keepyourchimneyclean Donot allow more than 1 16 creosote build up in your chimney The amount of creosote will depend on variables such as frequency of use and...

Страница 8: ...after a hot fire has been started Burn hardwoods Masking Soot See Photo 8 Combustor has not maintained a light off Burning coal will cause a sulfur based compound to coat the catalyst Place combustor...

Страница 9: ...e Do not use abrasives such as steel wool or steel pads for they may scratch the door frame finish Ashes Whenever ashes get 3 to 4 inches deep in your firebox andwhenthefirehasburneddownand cooled rem...

Страница 10: ...door using the hinge screws see Figure 9 Figure 8 HINGE SCREWS GASKET ADJUSTEMENT SCREW DOOR HINGE SCREWS Figure 9 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO P...

Страница 11: ...nts The Villa Vista fireplace may be installed directly on a combustible floor The supplied safety metal strip must be positioned as fol lows One half under the front of the fireplace and the other ha...

Страница 12: ...llustrations and photographs are nottoscale consultinstallationinstructions Product designs materials dimensions specifications colorsandpricesaresubjectto change or discontinuance without notice Allf...

Страница 13: ...bustibles around chimney components required NOTE Blown or fill type insulation materials must not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcod...

Страница 14: ...he unit 38 and a height of 54 from the base of the appliance see Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Fig...

Страница 15: ...mum length See Figure 17 The height of the louver must be measured from the base of the Villa Vista fireplace to the middle point of the louver When installing the double outlet system the hotairoutle...

Страница 16: ...ral heating system Malfunction of the heating system s fan will cause the furnace duct to overheat A furnace duct is only single wall and not double wall as is required for the Villa Vista fireplace h...

Страница 17: ...basement or garage 4 The air intake register should be installed where it is not likely to be blocked by snow or exposed to extreme wind and well away fromautomobileexhaustfumes gasmeters and other ve...

Страница 18: ...ity Chimneys International Ltd 7 diameter chimney systems models ACBI or ASHT or S2100 or DuraVent model DuraTech DTC chimney systems NOTE Use of ACBI chimney with these fireplaces require the use of...

Страница 19: ...stallauniversalsupportfasteningthestrapsto thesurroundingjoists ASHT Installsupport as required see Chimney Support Installation Section on Page 22 4 Puttheroofflashinginplaceandsealthejoint between t...

Страница 20: ...45mm 19 483mm 21 3 8 545mm CrossSlopeHoleSize Putthechimneycapintoplace Washtheroofflashingwithasolvent or vinegar thenpaintitwithrust proof paint Table 2 1 Install the first elbow Turn it in the requ...

Страница 21: ...TC 15 Deviation 3 5 16 84 mm 4 5 16 110 mm 5 7 8 149 mm 7 7 16 189 mm 10 1 2 268 mm 13 5 8 346 mm 15 3 8 391 mm 16 7 16 418 mm 18 457 mm 19 1 2 495 mm 22 5 8 575 mm Length 15 11 16 398 mm 19 9 16 497...

Страница 22: ...ightly lift the chim neysystemsotheweightwilllieonthesupport notonthefireplacetoreduceexpansionnoises This support has two possible uses 1 For ASHT it must be used on a roof to support the chimney 2 I...

Страница 23: ...SHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimn...

Страница 24: ...r Chimney for Relining Masonry Chimneys Tubinox chimney or Projet SS 7 diameter with adaptor for installation in a masonry chimney NOTES Projet Nova Temp HT6000 is equivalent to S2100 Projet Nova Temp...

Страница 25: ...o flexible pipe adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2 clamps BISAF BISAF Thermopile gauge and label replacement J8004 CLEARANCE TO COMBUSTIBLES The followi...

Страница 26: ...orts Support Section 10 long ACBI7SL ACBI7SL Universal Support AC10SU AC10SU Roof Flashings 1 12 7 12 5 30 Adjustable ACBI7FAR ACBI7FAR 8 12 12 12 30 45 Adjustable ACBI7FBR ACBI7FBR Flat Roof Flashing...

Страница 27: ...r ordering information DuraTech DTC 1 High Temp Insulated Stainless Steel Chimney 7 I D and 11 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT and CAN ULC S629 Description Part Cat No Len...

Страница 28: ...ney Adaptor 45 BISPMA CANADA ONLY BISPMA 30 Adaptor for Masonry Chimney BISPMA30 BISPMA30 SECURITY CHIMNEYS PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimney...

Страница 29: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 30: ...CEMENT PARTS See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be...

Отзывы: