INSTALLATION INSTRUC

TIONS

P/N 506023-22   Rev. NC   12/2013 

This manual is one of a set of two supporting this product.  

Refer to P/N 506025-14 for Care and Operation Instructions.

Ce manuel est disponible en francais, simplement  

en faire la demande. Numéro de la pièce 506023-23.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile 

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating 

plate. This appliance is not convertible for use with other gases unless a certified kit is used.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.

CONSOMMATEUR : Conservez cette notice pour 

consultation ultérieure.

Montebello DLX

 40 and 45 in.   

Direct Vent Gas Fireplaces

MODELS

AVERTISSEMENT : Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire au

minimum le risque d’incindie ou d’explosion ou pour

éviter tout dommage matériel, toute blessure ou la mort.   

 

 

 

 

 

WARNING: If the information in these instructions

is not followed exactly, a fire or explosion may

result, causing property damage, personal injury,

or death.   

WARNING /AVERTISSEMENT/AVISO

HOT GLASS WILL 

CAUSE BURNS. 

DO NOT TOUCH GLASS 

UNTIL COOLED

NEVER ALLOW CHILDREN 

  TO TOUCH GLASS.

 

UNE SURFACE VITRÉE CHAUDE 

PEUT CAUSER DES BRÛLURES.

LAISSER REFROIDIR LA SURFACE 

  VITRÉE AVANT D'Y TOUCHER. 

NE PERMETTEZ JAMAIS À UN ENFANT 

  DE TOUCHER LA SURFACE VITRÉE.

  EL VIDRIO CALIENTE 

  CAUSARÁ QUEMADURAS. 

USTED DEBE NUNCA 

  TOCAR EL VIDRIO CALIENTE.

 

LOS NIÑOS DEBEN NUNCA 

  TOCAR EL VIDRIO.

- Do not store or use gasoline or other flammable

  vapors and liquids in the vicinity of this or any other

  appliance. 
- WHAT TO DO IF YOU SMELL GAS:

 s$ONOTT

ry to light any appliance.

 s$ONOTTOUCHANYELECTRICALSWITCHDONOTUSEANY

    phone in your building.

 s)MMEDIATELYCALLYOURGASSUPPLIERFROMA

    neighbor’s phone. Follow the gas supplier’s

    instructions.

 s)FYOUCANNOTREACHYOURGASSUPPLIERCALLTHEFIRE

    department.
- Installation and service must be performed by a

  qualified installer, service agency or the gas supplier.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs

  ou liquides inflammables dans le voisinage de cet appareil

  ou de tout autre appareil. 
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

 s.EPASTENTERDALLUMERDAPPAREIL

 s.ETOUCHEZÜAUCANINTERRUPTEU

r. Ne pas vous servir des

    téléphones se trouvant dans le bâtiment où vous trouvez.

 s!PPELEZIMM£DIATEMENTVOTREFOURNISSEURDEGAZDEPUIS

    un voisin. Suivez les instructions du fournisseur.

 s3IVOUSNEPOUVEZREJOINDRELEFOURNISSEURDEGAZ

    appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un

  installateur ou un service d’entretien qualifié ou par le

  fournisseur de gaz.

Decorative Product: Not for use as a heating appliance.

NOTICE:  Fireplace is not to be operated by a thermostat.  

MontebelloDLX45TEN
MontebelloDLX45TEP
MontebelloDLXCD45TEN
MontebelloDLXCD45TEP

MontebelloDLX40TEN
MontebelloDLX40TEP
MontebelloDLXCD40TEN
MontebelloDLXCD40TEP

Intertek Report No. 

100513650

Содержание MontebelloDLX40TEN

Страница 1: ...ER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO Do not store or use g...

Страница 2: ...LATEST EDITION TABLE OF CONTENTS 0ACKAGING 2 Introduction 2 ENERAL NFORMATION ASSACHUSETTS 2EQUIREMENTS 4 Cold Climate Insulation 5 ANUFACTURED OME 2EQUIREMENTS 5 OCATION 5 Vent Termination Clearance...

Страница 3: ...cessaires si les tapis la literie et cetera produisent une quantit importante de pous si re Il est essentiel que les compartiments abritant les commandes les br leurs et les con duits de circulation d...

Страница 4: ...2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 2 Manifold Gas Supply Pressure Fuel Low High Natural Gas 1 6 WC 4 kPa 3 5 WC 87 kPa Propane 6 3 WC 1 57 kPa 10 0 WC 2 49 kPa Table 3 REQUIREME...

Страница 5: ...ated manufactured home and MUST BE INSTALLED IN ACCORDANCE WITH THE MANU FACTURERgS INSTRUCTIONS AND THE ANUFACTURED Home Construction and Safety Standard Title 2 0ART IN THE 5NITED 3TATES OR THE 3TAN...

Страница 6: ...TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination Storm Collar Concentric Vent Pipe Flashing 1 25 4 mm Minimum Clearance to Combustibles Vert...

Страница 7: ...RAPPLIANCES 45 HR K7 CM FOR APPLIANCES 45 HR K7 AND 45 HR K7 CM FOR APPLIANCES 45 HR K7 CM FOR APPLIANCES 45 HR K7 CM FOR APPLIANCES 45 HR K7 AND 45 HR K7 CM FOR APPLIANCES 45 HR K7 LEARANCE TO MECHAN...

Страница 8: ...JECTIONS SUCH AS SHELVES WINDOW SILLS MANTELS ETC ABOVE THE APPLIANCE NOTE We recommend the use of high temperature paint rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COM...

Страница 9: ...e framing may be in direct contact with the nailing flanges and may be located closer than 1 2 from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Frame the opening to th...

Страница 10: ...ustrations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without not...

Страница 11: ...mproper installation such as this is not covered under the limited warranty Right Side Front Corner Of Fireplace Framing 6 1 4 159 mm 19 5 8 498 mm Step 2 ROUTING GAS LINE 2OUTE A MM GAS LINE ALONG TH...

Страница 12: ...directly to the outside The vent system may not service multiple APPLIANCES AND MUST NEVER BE CONNECTED TO A mUE SERVING A SEPARATE SOLID FUEL BURNING AP PLIANCE 4HE VENT PIPE IS TESTED TO BE RUN INS...

Страница 13: ...0 0 3 1 2 5 7 1 0 2 0 0 0 2 5 2 2 5 7 8 1 0 0 1 0 0 1 5 5 2 5 2 1 2 1 2 0 0 0 3 5 1 3 5 2 6 2 0 3 0 0 0 3 5 4 3 5 7 8 2 0 0 0 1 0 1 5 7 3 5 2 1 3 1 1 1 0 0 3 5 3 4 5 2 6 3 0 2 1 0 0 3 5 4 5 7 3 0 0 2...

Страница 14: ...Figure 17 D Install firestop spacer at ceiling 7HEN USING 3ECURE 6ENT USE 36 lRESTOP SPACER AT CEILING JOISTS F THERE IS LIVING SPACE ABOVE THE CEILING LEVEL THE lRESTOP SPACER MUST BE INSTALLEDONTHEB...

Страница 15: ...r initial collar section to align with the REQUIRED DIRECTION OF THE NEXT VENT RUN ELEMENT Twist elbow sections in a clockwise direction onlysoastoavoidthepossibilityofunlocking anyofthepreviouslyconn...

Страница 16: ...es s T IS VERY IMPORTANT THAT THE HORIZONTAL inclined run be maintained in a straight no dips slightly elevated plane The recommended incline is approximately 1 4 perfoot 20mmpermeter horizontal in a...

Страница 17: ...ions Continue with the installation of the straight vent sections in horizontal inclined RUN AS DESCRIBED IN Step E on Page 14 Install SUPPORT STRAPS EVERY FEET MM ALONG horizontal inclinedventrunsusi...

Страница 18: ...mum Distance to Base of Appliance To help minimize water infiltration it is recommended that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall J Assemble vent run to exterior w...

Страница 19: ...6 18 5 5 6 9 5 2 9 20 6 0 10 3 0 V H 40 feet 12 4 m Max H 20 ft 6 2 m Max HORIZONTAL VENT FIGURES TABLES NOTES s 3ECURE 6ENT components rigid vent pipe and terminal are shown in the figures s Two 45...

Страница 20: ...Ceiling Firestop Spacer SV8BF Table D H H1 Maximum V Minimum feet meter feet meter 3 5 1 07 2 5 0 762 6 5 1 98 3 5 1 07 8 5 2 6 4 5 1 37 10 5 3 2 5 5 1 68 12 5 3 8 6 5 1 98 14 5 4 4 7 5 2 3 16 5 5 0 8...

Страница 21: ...l Code Verify proper operation after servicing S assurer que l appareil fonctionne ad quatement une fois l entretien termin A wiring diagram is provided here for reference purposes only This informati...

Страница 22: ...RECEIVER FRONT COVER INSERT THE END OF A PAPER CLIP OR OTHER SIMILAR OBJECT NOT PROVIDED INTO THE HOLE MARKED h02 v 4HE RECEIVER WILL hBEEPv THREE TIMES TO indicate it is ready to synchronize with the...

Страница 23: ...ng codes by a quali fied installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation mustbeperformedbyalicensed plumber or gas fitter Gas Valve 3 8...

Страница 24: ...o use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality s Logs get very hot and will remain hot up to one hour after g...

Страница 25: ...Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 OG ENTER 2 OG 2EAR OG ENTER EFT 4 OG ENTER 2IGHT 5 OG 2EAR 4OP 6 OG RONT EFT OG RONT ENTER Table 6 Log Set Align Hole At Bottom Of Log 5 Over Th...

Страница 26: ...rate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in ACHIEVING THE CORRECT AIR SHUTTER ADJUSTM...

Страница 27: ...NUALLY OPERATED ADJUST THE AIR SHUTTER CLOSEDASDESCRIBEDINTHEPREVIOUSPARAGRAPHS Operatetheapplianceforaperiodoftimeasthe effect diminishes ensuring that the appliance DOES NOT DEVELOP SOOTY mAMES 7HEN...

Страница 28: ...ay shaded area must be non combustible or Dura Rock Header 2x4 s Spacers Top of Door Frame Fireplace right side Combustible Finished Wall Materials 1 Installations with horizontal terminations which h...

Страница 29: ...use MENT POUR LIMINER LA POUSSI RE ET LES TRACES DEGRAISSEOUD HUILE OLLEZL TIQUETTESURLEBO TIER de la t l commande Figure B Choisissez la LANGUE QUI EST PRINCIPALEMENT PARL E DANS LA r sidence du prop...

Страница 30: ...H2258 SV8FA 1 12 to 7 12 Adjust able Flashing H2259 SV8FB 7 12 to 12 12 Adjustable Flashing H3237 SV8SC6 Storm Collars 6 pack H2260 SV8HF Firestop Spacer Horizontal 3 1 1 spacing H2261 SV8BF Firestop...

Страница 31: ...manufacturer s instructions and all applicable codes andrequirementsoftheauthorityhavingjurisdiction Iftheinformationin these instruction is not followed exactly a fire explosion or production of carb...

Страница 32: ...14 TTACH THE CONVERSION LABEL PROVIDED IN THE CONVERSION KIT TO THE RATING PLATE ON THE appliance Step 15 Apply gas to the system and relight APPLIANCE 7ITH THE MAIN BURNER TEST THE NEW PRESSURE REGU...

Страница 33: ...33 6 4 6 24 02 5 43 s 2 4 6 4 3 2 0 3 ONTEBELLO 8 ONTEBELLO 8 s 34 4 3425 4 3 NOTES...

Страница 34: ...NOVATIVE EARTH 0RODUCTS RESERVES THE RIGHT TO MAKE CHANGES AT ANY TIME WITHOUT NOTICE IN DESIGN MATERIALS SPECIlCATIONS AND PRICES AND ALSO TO DISCONTINUE COLORS STYLES AND PRODUCTS ONSULT YOUR LOCAL...

Отзывы: