VENTING INSTALLATION
Continued
10 FOOT RULE
All flue gas outlet chimney terminations must extend a minimum of
3 feet in height above the highest point where it passes through the
roof and must be at least 2 feet above the highest point of the roof
that is within a horizontal distance of 10 feet (see Figure 25).
FINISHING FIREPLACE
Combustible materials, such as wallboard, gypsum board, sheet
rock, drywall, plywood, etc. may not make direct contact with sides
and top around the fireplace face. See clearance requirements in Fig-
ures 8 and 9 on page 10. It is important that combustible materials do
not overlap the face itself. Brick, glass, tile or other noncombustible
materials may overlap the front face provided they do not obstruct
essential openings. When overlapping with a noncombustible facing
material, use only noncombustible mortar or adhesive.
MASONRY (PRECAST) CHIMNEY
Masonry Chimney may be used instead of the IHP Chimney System.
Parts come in 14" Diameter and can be obtained by IHP. See Acces-
sories on page 36.
24" (610 mm)
Min.
24" (610 mm)
Min.
18"
(458 mm)
Min. Typ.
10
'
(3.048 m)
2
'
(0.6096 m) Min.
2
'
(0.6096 m)
Min.
3
'
(0.9144 m)
Min.
3
'
(0.9144 m)
Min.
10
'
(3.048 m)
Figure 24 - Multiple Chase Installation
Level of Flue
Gas Outlet
Figure 25 - 10 Foot Rule
OPTIONAL GAS LINE INSTALLATION
You may elect to add a vented decorative gas appliance (gas log) to
your Grand Meridian Fireplace. If so, follow the installation instruc-
tions from the Decorative Gas Appliance manufacturer. Familiarize
yourself with requirements for installation as outlined by the Na-
tional Fuel Gas Code, ANSI Z223.1/NFPA 54. This gas pipe provi-
sion should only be used on a decorative gas appliance.
You can route the gas piping practically anywhere in the firebox –
the floor, back wall or side walls. You will just need a masonry drill;
the instructions from the gas appliance manufacturer will be very
straightforward.
Fill in the holes you have drilled around the gas piping with the
regular mortar.
Follow the Gas Log manufacturer’s instructions.
OPTIONAL ELECTRICAL CONNECTION INSTALLATION
Like the gas line, electrical feed lines can be run through the floor,
back wall, or side walls. Follow local building and electrical code