Astria.us.com
125160-01_D
11
PRE-INSTALLATION PREPARATION
Continued
W1
H1
A
A
SECTION A-A
SECTION A-A
DET
"C"
LINTEL
DETAIL "C"
W1
H4
A
A
DET
"C"
H3
H3
NON-COMBUSTIBLE FLOOR
H2
H5
28
"
(712 mm)
2
"
(51 mm)
28
"
(712 mm)
2
"
(51 mm)
2
"
(51 mm) MIN.
1
"
(26 mm) THICK CERAMIC
FIBER INSULATION BLANKET
2
"
(51 mm) MIN.
2
"
(51 mm) MIN.
2
"
(51 mm)
MIN.
LINTEL TOP
LINTEL TOP
2
"
(51 mm) MIN.
CLEARANCE TO COMBUSTIBLES
2
"
(51 mm)
MIN. AIRSPACE
CLEARANCE TO
COMBUSTIBLE
FRAMING
2
"
(51 mm) MIN.
CLEARANCE TO COMBUSTIBLES
MAINTAIN 2
"
(51 mm) CLEARANCE
TO WOOD FRAMING
MAINTAIN 2
"
(51 mm) CLEARANCE
TO WOOD FRAMING
2
"
(51 mm)
AIRSPACE
CLEARANCE TO
COMBUSTIBLES
ON REAR AND
SIDES OF UNIT
2
"
(51 mm)
AIRSPACE
CLEARANCE TO
COMBUSTIBLES
ON REAR AND
SIDES OF UNIT
1
/
2
"
(13 mm)
CEMENT BOARD
1
/
2
"
(13 mm)
CEMENT
BOARD
METAL
PLATFORM
FLOOR JOIST
BRACE
METAL
PLATFORM
Figure 11 - Combustible Floor
Figure 10 - Non Combustible Floor
Model
W1
H1
H2
H3
H4
H5
MM33 41
"
(1042 mm)
32-½
"
(826 mm)
56-¼
"
(1429 mm) 7
"
(178 mm) 39-½
"
(1004 mm) 63-¼
"
(1607 mm)
MM39 47
"
(1194 mm) 40-½
"
(1029 mm)
64-¼
"
(1632 mm) 7
"
(178 mm) 47-½
"
(1207 mm) 71-¼
"
(1810 mm)
MM44 52
"
(1321 mm) 40-½
"
(1029 mm)
64-¼
"
(1632 mm) 7
"
(178 mm) 47-½
"
(1207 mm) 71-¼
"
(1810 mm)
MM49 57
"
(1448 mm) 40-½
"
(1029 mm)
64-¼
"
(1632 mm) 7
"
(178 mm) 47-½
"
(1207 mm) 71-¼
"
(1810 mm)
MM63 71
"
(1804 mm) 42-¾
"
(1086 mm)
75
"
(1905 mm)
9
"
(229 mm) 51-¾
"
(1315 mm)
84
"
(2134 mm)