Installation
900005-00, 10/2015
Innovative Hearth Products
Envy™ Direct-Vent Gas Fireplaces
15
Figure 5 - Combustible Side Clearances
Figure 6 - Mantel Height
Wall Finishes / Surrounds / Mantels
NOTE:
Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined
by the fireplace front face (black sheet metal).
Never allow combustible materials to be positioned in front of or
overlapping the fireplace face (
Figure 42
).
Non-combustible materials, such as surrounds and other fireplace trim, may be installed on the fireplace face, but they
must not cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel (
Figure 6
). Mantels
constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do
not allow anything to hang below the fireplace hood. Minimum clearance requirements include any projections such
as shelves, window sills, mantels, etc. above the fireplace.
NOTE:
To avoid heat-related finish damage, use finish materials rated 175 °F, or higher, on the underside of the mantel.
INSTALLATION PREPARATION
The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1.
Remove the shipping carton and the shipping pad.
2.
Remove the top louver, then remove the surround trim assembly by detaching it at the top of the fireplace and
lifting it 1” to disengage the side tabs, then pulling it away from the fireplace exposing the front glass door.
Figure 7 - Removing the surround trim assembly
SCALE 0.200
Side Tabs
3.
Locate the four (4) spring-loaded latches; two above and two
below the glass door (
Figure 57
).
4.
Release the lower latches, by pulling each handle out and
down to unhook it from the glass door.
5.
Lightly press against the door, to hold it in position, while
releasing the two upper latches.
6.
Carefully grip the door at the top and bottom, and remove it
from the fireplace. Place the door in a secure location where it
will not be damaged.
in. (mm)
12
(305)
10
(254)
8
(203)
6
(152)
4
(102)
2
(51)
18 (457)
20 (508)
22 (559)
24 (607)
26 (660)
28 (711)
Standoff
Top of fireplace
Mantel Depth
Mantel Height
5 (127)
12 (305)
Top View of
Fireplace
45
o
Protected wall shown in white
in. (mm)
Combustible materials
may project beyond
one side
of the fireplace
opening as long as
they are kept within the
shaded areas illustrated
here.
Combustible Materials
Allowed In Shaded
Area “Safe Zone”
Combustible Walls
shown in dark gray
At 5-1/2”
side wall
clearance, a
combustible
wall can
project 5”
At 14-1/2”
minimum
side wall
clearance, a
combustible
wall can
project to
any length.
At 13-3/4”
side wall
clearance, a
combustible
wall can
project 12”