background image

SAFETY

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can cause serious injury or death 

from  burns,  fire,  explosions, 

electrical shock and carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

This fireplace is a vented product. This fireplace 

will not produce any gas leakage into your home 

if  properly  installed. This  fireplace  must  be 

properly installed by a qualified service person. 

If this unit is not properly installed by a qualified 

service person, gas leakage can occur.

Carbon Monoxide Poisoning:

 Early signs of 

carbon monoxide poisoning resemble the flu, 

with headaches, dizziness or nausea. If you 

have these signs, the fireplace may not have 

been installed properly. 

Get fresh air at once!

 

Have fireplace inspected and serviced by a 

qualified service person. Some people are more 

affected by carbon monoxide than others. These 

include pregnant women, people with heart or 

lung disease or anemia, those under the influ

-

ence of alcohol and those at high altitudes.
Propane/LP  gas  and  natural  gas  are  both 

odorless. An  odor-making  agent  is  added 

to each of these gases. The odor helps you 

detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present 

even though no odor exists.
Make  certain  you  read  and  understand  all 

warnings. Keep this manual for reference. It 

is your guide to safe and proper operation of 

this fireplace.

 WARNING: Any change to 

this fireplace or its controls can 

be dangerous.

1.  This appliance is only for use with the type 

of gas indicated on the rating plate. This 

appliance is not convertible for use with 

other gases unless a certified kit is used.

2.  For  propane/LP  fireplace,  do  not  place 

propane/LP  supply  tank(s)  inside  any 

structure.  Locate  propane/LP  supply 

tank(s) outdoors. To prevent performance 

problems, do not use propane/LP fuel tank 

of less than 100 lbs. capacity.

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup

-

plier's instructions

• if you cannot reach you gas supplier, call 

the fire department.

4. 

Never install the fireplace 

• in a recreational vehicle

• where curtains, furniture, clothing or other 

flammable objects are less than 36" from 

front and 42" from top of fireplace. For 

side clearances see Figure 6, page 7

• in high traffic areas

• in windy or drafty areas

5.  This fireplace reaches high temperatures. 

Keep children and adults away from hot 

surfaces to avoid burns or clothing igni

-

tion. Fireplace will remain hot for a time 

after  shutdown. Allow  surfaces  to  cool 

before touching.

6.  Carefully supervise young children when 

they are in the room with fireplace.

7.  A hearth extension is not required with this 

appliance. If one is installed, it is for aes

-

thetic purposes only and does not have 

to meet the standard requirements.

8.  Turn fireplace off and let cool before ser

-

vicing or repairing. Only a qualified service 

person  should  install,  service  or  repair 

this  fireplace.  Have  fireplace  inspected 

annually by a qualified service person.

9.  You  must  keep  control  compartments, 

burners and circulating air passages clean. 

More frequent cleaning may be needed due 

to excessive lint and dust from carpeting, 

bedding material, etc. Turn off the gas valve 

and pilot light before cleaning fireplace.

10. Have venting system inspected annually 

by a qualified service person. If needed, 

have venting system cleaned or repaired. 

See 

Cleaning and Maintenance

, page 21.

f i r e - p a r t s . c o m

Содержание Mission36TEN

Страница 1: ...ty damage personal injury or death AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incindie ou d explosion ou pour viter tout d...

Страница 2: ...e absence of these codes complies with the National Fuel Gas Code ANSIZ223 1 NFPA 54 State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas...

Страница 3: ...nce is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propane LP supply tank s out...

Страница 4: ...Shrink wrapped on cardboard Three 3 plastic bags containing lava rock pan and ember materials Rear Log Remove two plastic quick ties from around burner and grate Grate Stand Lift off of burner pan Ch...

Страница 5: ...closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa For the purpose of input adjustment two...

Страница 6: ...5 WC 2 66 kPa 10 5 WC 2 66 kPa Orifice Size 30 29 GAS RATING PROPANE LP Max Input Rating 40 000 Btu Hr 45 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74...

Страница 7: ...e components in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section 1 1 2 3 8 cm Max...

Страница 8: ...eenthemate rial used and the face is caulked withanoncombustiblecaulking Figure 7 Rough Opening for Installing in Wall B C A Figure 8 Corner Installation Guidelines A B C D These Dimensions Allow for...

Страница 9: ...line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR...

Страница 10: ...um height in accordance with the roof pitch and a minimum of 8 ft distance from a vertical wall or obstruction see Figure 11 page 11 A B type venting system must be connected to appliance for venting...

Страница 11: ...lation It is not recommended that this appliance be common vented with an existing gas burning appliance However if it becomes necessary to common vent this appliance the venting system must be sized...

Страница 12: ...l Receiver Extension Cord Ignition Module Plug NOTICE This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of aventingproblem Donotbypass thevent...

Страница 13: ...black iron gas line be routed from the gas source through a sediment trap shown in Figure 18 and into appliance Once connected through appliance a flexible gas line may be used for ease of installatio...

Страница 14: ...aks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected INSTALLATION Continued Complete your gas installation by connect ing incomin...

Страница 15: ...on left of log 2 see Figure 25 Rest lower end of log 5 on grate as shown in Figure 26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6...

Страница 16: ...upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log 1 see Figure...

Страница 17: ...Between Appliance and Framing INSTALLING OPTIONAL GLASS DOOR ACCESSORY CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individuals If this is...

Страница 18: ...ide pins are free of frame rail see Figure 35 CAUTION Always operate the appliance with the doors ei ther fully opened or fully closed Operating the appliance with the doors partially open can re sult...

Страница 19: ...justment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A T...

Страница 20: ...o press ON OFF buttons on hand held remote control unit for up to 3 seconds to assure proper operation 2 Press the ON OFF button to turn burner on and off Check pilot flame pattern and burner flame pa...

Страница 21: ...n cleaning is complete Burner and controls should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint LOGS I...

Страница 22: ...at 1 800 655 2008 When calling please have your model and serial numbers of your fireplace ready You can also visit INNOVATIVE HEARTH PRODUCTS s web site at IHP US com IMPORTANT NOTICE Young children...

Страница 23: ...MEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after repeated attempts appliance does...

Страница 24: ...as low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas lea...

Страница 25: ...ed Brass Finish BD42P 42 Platinum Finish FIXED GLASS DOORS FD36 36 Black Finish FD36B 36 Brushed Brass Finish FD36P 36 Platinum Finish FD42 42 Black Finish FD42B 42 Brushed Brass Finish FD42P 42 Plati...

Страница 26: ...0858 F0860 AND F0862 MISSION42TEN CATALOG NUMBERS F0864 F0866 AND F0868 51 21 1 10 11 6 50 50 22 3 8 20 9 52 13 43 14 45 48 44 40 23 4 39 17 2 42 41 9 54 54 46 19 47 7 53 53 47 18 5 16 12 15 52 33 31...

Страница 27: ...1 25 11165 11165 Screw 10 x 5 8 2 26 107796 01 107796 02 Grate Assy 1 27 107742 01 107742 02 Burner Pan 1 28 107795 01 107831 01 Burner Tube 1 29 107748 01 107748 01 Burner Brckt 1 30 107985 01 107985...

Страница 28: ...1 108166 01 108171 01 Rear Refractory Herringbone 1 15 106661 01 107818 01 Bottom Rear Refractory Std Brick 1 108167 01 108172 01 Bottom Rear Refractory Herringbone 1 16 106662 01 107820 01 Bottom Fr...

Страница 29: ...AND F0862 KEY NO PART NO DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 01 T...

Страница 30: ...Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720 01 Top Right...

Страница 31: ...r acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Pro...

Страница 32: ...arranty verification P126754 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications pricesandalsotodiscontinuecolors stylesandpr...

Отзывы: