34

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective

1. Residues from manufac-

turing processes and logs 

curing

1. Turning control knob to HI 

position when burners are 

cold

2. Air in gas line

3. Air passageways on appli-

ance blocked

4. Dirty or partially clogged 

burner orifice(s)

1. When heated, vapors from 

furniture polish, wax, carpet 

cleaners, etc. may turn into 

white powder residue

1. Not enough combustion/

ventilation air

1. Battery is not installed. Bat-

tery power is low

1. Metal expanding while 

heating or contracting while 

cooling

2. Wire connection loose or 

wire broken

REMEDY 

1. Check burner(s) for dirt 

and debris. If found, clean 

burner(s) 

(see Cleaning and 

Maintenance, 

Page 30

)

2. Replace gas regulator

1. Problem will stop after a few 

hours of operation

1. Turn control knob to LO 

position and let warm up 

for a minute

2. Operate burners until air is 

removed from line. Have 

gas line checked by local 

natural or propane/LP gas 

company

3. Observe minimum installa-

tion clearances 

(see 

Pages 

9 through 11

)

4. Clean burners 

(see Clean-

ing and Maintenance, 

Page 30

or replace burner 

orifice(s)

1. Turn appliance off when 

using furniture polish, wax, 

carpet cleaners or similar 

products

1. Refer to 

Air for Combustion 

and Ventilation

 require-

ments 

(

Page 6

)

1. Replace 9-volt batteries 

in receiver and hand-held 

remote

1. This is normal with most 

appliances. If noise is ex-

cessive,  contact  qualified 

service person

2. Check wiring connections 

(see wiring diagram, 

Page 

31

).

 Replace wire harness 

if necessary.

OBSERVED PROBLEM

Yellow flame in front burner 

during burner combustion

Slight smoke or odor during 

initial operation

Appliance produces a whis-

tling noise when burners 

are lit

White powder residue form-

ing within burner box or on 

adjacent walls or furniture

Moisture/condensation no-

ticed on windows

Remote does not function 

(Remote-Ready Models 

Only)

Appliance produces a click-

ing/ticking noise just after 

burners are lit or shut off

TROUBLESHOOTING

Continued

f i r e - p a r t s . c o m

Содержание MAGNIFLAME24MN

Страница 1: ...B MAGNIFLAME24MN SOUTHERNCOMFORT36A B MAGNIFLAME24MP MAGNIFLAME24VP SHADYHOLLOW30A B MAGNIFLAME30VN SHADYHOLLOW24A B MAGNIFLAME30MN SHADYHOLLOW36A B MAGNIFLAME30MP MAGNIFLAME30VP P N 126807 01 REV D 0...

Страница 2: ...ce in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNING This is an unvented gas firedheater Itusesair oxygen from...

Страница 3: ...orynotapprovedforusewith this appliance WARNING Do not allow fans to blow directly into the heater Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner fl...

Страница 4: ...adjacent walls and furniture 10 This appliance needs fresh outside air ventilation to run properly This appliance has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the appl...

Страница 5: ...Quincy MA 02169 7471 UNPACKING 1 Remove log set assembly from carton CAUTION Donotremovethe data plates from the grate as sembly The data plates contain important warranty and safety information COMM...

Страница 6: ...G ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilatio...

Страница 7: ...alled in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that spac...

Страница 8: ...r into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figure 2 Ventilati...

Страница 9: ...e in a bedroom or bathroom unless installed as a vented appliance see Page 12 in a recreational vehicle wherecurtains furniture clothing orotherflammableobjectsareless than 36 from front 42 from top o...

Страница 10: ...e material must extend at least 8 up for all models If noncombustible material is less than 12 you must install the fireplace hood accessory 24 and 30 Models Only See Figure 5 for minimum clearances I...

Страница 11: ...ng FLOOR CLEARANCES A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace...

Страница 12: ...l keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue ope...

Страница 13: ...bricks 4 Remove appliance base from fireplace 5 Drill holes at marked locations using 3 16 drill bit 6 Attachbase throughholesinbacksidepan els of base to fireplace floor using masonry screws provided...

Страница 14: ...ater to allow proper gas volume to appliance If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap with...

Страница 15: ...valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage appliance regulator 2 Cap off open end of gas pipe where equip ment shutoff valve...

Страница 16: ...ries are available separately see Accessories Page 40 Read instructions shipped with remote control along with instructions below before attempting installation 1 If unit is already installed in firep...

Страница 17: ...switch is in OFF posi tion before installing or chang ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not included To ins...

Страница 18: ...withthese diagrams or failure to use only parts specifically approved with thisappliancemayresultinprop erty damage or personal injury Magniflame SERIES BURNER SYSTEM LOG COMPATIBILITY CHART ence The...

Страница 19: ...ng Right Front Log Side View Figure 25 Installing Back Left Log Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 25A Installing Back Left Log Figure 25B Installing Back...

Страница 20: ...ng Charred Log Top View Figure 27B Installing Charred Log Top Side View Square Grate Log Notch right side The left side of the burner tube fits into the notch on the back side of this log The log is p...

Страница 21: ...B m o d e l s D 023 SouthernComfort36A B or ShadyHollow36A B models D 029 See Figures 31 and 31A The left end of this log has a round hole that fits over the round peg that is on the top of the back l...

Страница 22: ...ed to come in contact with either the burner ports or flame around base of appliance if desired DO NOT place rock or additional logs on front burner or on logs except as directed above Placing any mat...

Страница 23: ...m and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Iffireplacehasglassdoors never operate this appliance with glass doors closed If you operate ap pliance with doors closed...

Страница 24: ...s appliance for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds or more This will allow air to bleed from the gas system 7 With control kn...

Страница 25: ...ou can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave selector switch in the REMOTE or ON position when pilot is not lit This will drain the battery NOTE Do not h...

Страница 26: ...tion O F F PILOT O N Control Knob Igniter Button 7 With control knob pressed in press and release igniter button This will light pilot The pilot is attached to the front burner If needed keep igniter...

Страница 27: ...ute heated air from the fireplace NOTE Periodically check the louvers of the firebox and remove any dust dirt or other obstructions Figure 40 Pilot Natural Propane LP HAND HELD REMOTE OPERATION BATTER...

Страница 28: ...levels see Figure 44 Select manual flame height function by press ing MODE button until a flame is shown in lower left corner of display Use UP DOWN arrow button to set desired flame height see Figur...

Страница 29: ...plate marked PRG The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter Press the ON OFF button on your remote and the receiver will beep 4 times to confirm it rece...

Страница 30: ...or dust and dirt see Figure 51 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust dirt lint or pe...

Страница 31: ...ectronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment To Thermopile To AUTO Terminal on Switch To OFF Terminal on Switch WIRING DIAGR...

Страница 32: ...nes when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Overlap ember material 1 4 see Page 22 1 Reconnect igniter cable 2 Fre...

Страница 33: ...ed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS...

Страница 34: ...ne Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see Pages 9 through 11 4 Clean burners see Clean ing and Maintenance Page 30 or replace b...

Страница 35: ...Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Hand held remote control...

Страница 36: ...2 13 14 15 16 17 18 19 10 20 21 22 23 24 25 26 27 34 28 29 WARNING Failure to position the parts in accordance with these diagrams or failure to use onlypartsspecificallyapprovedwiththisheatermayresul...

Страница 37: ...3841 Knob Short Extension HI LO 1 9 J3562 Male Connector 1 10 J7716 Tube Inlet 1 11 J6364 Asm Pan Burner 1 12 J6147 Bracket Front Burner 2 13 J3547 Nut Captive Washer 2 14 J4886 Air Shutter 1 15 J6127...

Страница 38: ...28 D 026 Log Back Left 1 3 J6698 D 059 J6518 D 017 J6529 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J6699 D 063 J6520 D 021 J6530 D 028 Log Middle Split 1 6 J6521 D 0...

Страница 39: ...CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8245 D 061 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8246 D 060 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8247 D 059 J8255 D 017 J8261 D 025 Log Fro...

Страница 40: ...stions concerning the installation or ap plication of this appliance please contact your dealer SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition ap...

Страница 41: ...Model FDVS For all models Order when addi tional volcanic stone is desired EMBER KITS Platimun Embers Cat No J6207 Glowing Embers rockwool Cat No J6208 FLOOR MEDIA KIT Cat No F1762 Model FM100 For all...

Страница 42: ...RECEIVER AND REMOTE CONTROL KIT Cat No F1079 Model TSRC For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is programmable for...

Страница 43: ...the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided wi...

Страница 44: ...iance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and...

Отзывы: