11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900299-01, 05/2016
Innovative Hearth Products
Libra
™
Series Direct-Vent Gas Fireplaces
WARNING
Failure to position the parts in
accordance with these diagrams
or failure to use only parts
specifically approved with this
appliance may result in property
damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de
blessures si les pièces ne sont
pas installées conformément à
ces schémas et ou si des pièces
autres que celles spécifiquement
approuvées avec cet appareil
sont utilisées.
MINIMUM CLEARANCES
*
Inches (millimeters)
Back and Sides
1/2" (13)
0 (0) from Spacers Or Dimples **
Top Spacers
0 (0)
Floor
0 (0)
From Bottom of Unit To Ceiling
64 (1626)
Vent
3 (77)
Top
* / 1 (26)
Sides & Bottom
SERVICE CLEARANCES
Feet (meters)
Front, Back, Sides
3 feet (0.9 meters)
Table 5
Figure 10 - Unit Parts Identification
DETAILED INSTALLATION STEPS
The appliance is shipped with all gas controls
and components installed and pre-wired.
1. Remove the shipping carton.
2. Remove Front Face Assembly (refer to
Figure 11) by lifting and pulling straight
out from the fireplace.
3. Lift the pressure relief plates and remove
the cardboard from underneath each of
them.
4. Open the two latches (located under the
firebox floor) securing the glass enclosure
panel. Remove the panel by tilting it outward
at the bottom and lifting it up. Set the door
aside protecting it from inadvertent damage.
See Figure 63 on Page 36.
Top View of
Fireplace
Combustible Walls
A Combustible Wall
may extend to any
length on one side
only. If installed as
shown, opposite side
is limited to 6".
6"
Figure 9
Control Compartment Access Panel
Front face assembly
Barrier
Control Compartment (behind assembly)
Hood