NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Installation and Operation Instructions

900299-01, 05/2016

Innovative Hearth Products
Libra

™ 

Series Direct-Vent Gas Fireplaces

The unitized design of the Secure Vent compo-

nents will engage and seal both the inner and 

outer pipe elements with the same procedure.  

Sealant and securing screws are not required.

NOTE: An elbow may also be attached to the 

appliance collar.  Attach in the same manner as 

you would a vent section. 

E.  Attach vent components to each other - Other 

vent sections may be added to the previously 

installed section in accordance with the require-

ments of the vent tables.  To add another vent 

component to a length of vent run, align the 

dimpled end of the component over the inclined 

channel end of the previously installed section, 

adjusting the radial alignment until the four lock-

ing dimples are aligned with the inlets of the four 

incline channels of the previous section.  Push 

the vent component against the previous section 

until it fully engages, then twist the component 

clockwise running the dimples down and along 

the incline channels until they seat at the end of 

the channels. This seating position is indicated 

by the alignment of the arrow and dimple as 

shown in Figure 28 on Page 19.

F. Install firestop/spacer at ceiling - 

When using Secure Vent, use SV4.5VF firestop/

spacer at ceiling joists; when using Secure Flex, 

use SF4.5VF firestop/spacer. If there is living 

space above the ceiling level, the firestop/ 

spacer must be installed on the bottom side of 

the ceiling. If attic space is above the ceiling, 

the attic insulation shield must be installed on 

the top side of the joist.  Route the vent sections 

through the framed opening and secure the 

firestop/spacer with 8d nails or other appropriate 

fasteners at each corner.

Remember to maintain 1" (26 mm) clearance 

to combustibles, framing members, and attic 

or ceiling insulation when running vertical 

chimney sections.

HORIZONTAL (OUTSIDE WALL) 

TERMINATION SYSTEM
Figures 40, and Figures 43 to 48 
on Pages 

25 to 27 and their associated  Horizontal Vent 

Table illustrate the various horizontal venting 

configurations that are possible for use with 

these appliances.  Secure Vent

®

 pipe applica-

tions are shown in these figures; Secure Flex

® 

pipe may also be used. A Horizontal Vent Table 

summarizes each system’s minimum and 

maximum vertical and horizontal length values 

that can be used to design and install the vent 

components in a variety of applications.
Both of these horizontal vent systems terminate 

through an outside wall. Building Codes limit 

or prohibit terminating in specific areas. Refer 

to Figure 6 and Page 7 for location guidelines.
Secure Vent SV4.5 Direct-Vent system compo-

nents are unitized concentric pipe components 

featuring positive twist lock connection, (refer 

to Figure 28 on Page 19).  All of the appliances 

covered in this document are fitted with collars 

having locking inclined channels. The dimpled 

end of the vent components fit over the appliance 

collar to create the positive twist lock connection.

A. Plan the vent run - 

Analyze the vent routing and determine the 

types  and  quantities  of  sections  required       

4-1/2" (114 mm), 10-1/2" (267 mm), 22-1/2" (572 

mm), 34-1/2" (876 mm) and 46-1/2" (1181 mm) net 

section lengths are available.  It is recommended 

that you plan the venting so that a joint does not 

occur in the ceiling or roof joists.  Allow for elbows 

as indicated in Figure 30 on Page 18
Maintain a minimum 1" (26 mm) clearance to 

combustibles on the vertical sections. Clearances 

for the horizontal runs are; 3" (77 mm) on top, 1" 

(26 mm) on sides, and 1" (26 mm) at the bottom.

B. Frame exterior wall opening - 

Locate the center of the vent outlet on the exterior 

wall according to the dimensions shown in Figures 

13, through 16 on Page 13.  Cut and/or frame an 

opening, 10-1/2" x 12-1/8" (267 mm x 308mm) 

inside dimensions, about this center.

C. Frame ceiling opening - If the vertical route 

is to penetrate a ceiling, use plumb line to locate 

the center above the appliance. Cut and/or frame 

an opening, 10-1/2" x 10-1/2" (267 mm x 267 

mm) inside dimensions, about this center (refer 

to Figure 26 on Page 19).

D. Attach vent components to appliance - To 

attach a vent component to the appliance collar, 

align the dimpled end over the collar, adjusting the 

radial alignment until the four locking dimples are 

aligned with the inlets of the four incline channels 

on the collar (refer to Figure 27 on Page 19).

Push the vent component against the collar until it 

fully engages, then twist the component clockwise, 

running the dimples down and along the incline 

channels until they seat at the end of the channels. 

G. Support the vertical run sections - 

On the vertical run, support the venting sys-

tem every 8 feet (2.4m) above the fireplace 

vent outlet with field-provided support straps 

(Plumber's tape).  Attach the straps to the vent 

pipe and secure to the framing members with 

nails or screws. See  Figure 29 on Page 19.

H. Change vent direction -  At transition 

from or to a horizontal/inclined run, install the 

SV4.5E45 and SV4.5E90 elbows in the same 

manner as the straight vent sections.  The 

elbows feature a twist section to allow them 

to be routed about the center axis of their 

initial collar section to align with the required 

direction of the next vent run element. Twist 

elbow sections in a clockwise direction only 

so as to avoid the possibility of unlocking any 

of the previously connected vent sections. 

See Figure 30 on Page 18.

I. Continue installation of horizontal/inclined 

sections -  Continue with the installation of the 

straight vent sections in horizontal/inclined run 

as described in Step E. Install support straps 

every 5 ft. (1.52 m) along horizontal/inclined 

vent runs using conventional plumber’s tape. 

See Figure 40, it is very important that the 

horizontal/inclined run be maintained in a 

straight (no dips) and recommended to be in 

a slightly elevated plane, in a direction away 

from the fireplace of 1/4" rise per foot (20 mm 

per meter) which is ideal, though rise per foot 

run ratios that are smaller are acceptable all the 

way down to at or near level.  Use a carpenter’s 

level to measure from a constant surface and 

adjust the support straps as necessary. 

It is important to maintain the required clear-

ances to combustibles: 1" (26 mm) at all sides 

for all vertical runs; and 3" (77 mm) at the 

top, 1" (26 mm) at sides, and 1" (26 mm) at 

the bottom for all horizontal/inclined runs.

Figure 40 - TYPICAL HORIZONTAL VENT INSTALLATION

Horizontal / Inclined Run

Support

Brackets

Building

Support

Framing

SV4.5E90

Elbow

Ceiling

u

 Firestop / Spacer

SV4.5VF

u

 When Using Secure Flex, 

Use Firestop / Spacer SF4.5VF

Fireplace

SV4.5L6/12/24/36/48

Vent Sections

Vertical

Rise

SV4.5HT-2

Termination

Shown

Support Bracket Spacing

Every 5 ft (1.52 m)

Exterior

Wall

SV4.5HT-2

Termination

Shown

See Figure 29 on Page 17  for 

vertical vent section support.

Содержание LibraCL40DEN

Страница 1: ...rnisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par le...

Страница 2: ...UCHER LA VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lu...

Страница 3: ...causar quemaduras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para i...

Страница 4: ...rative volcanic stone and one bag of vermiculate is located in the bottom compartment 5 oneventrestrictortobeappliedasshownon Page14 restrictoristapedtotheenvelope 6 barriers 7 front face assemblies N...

Страница 5: ...e of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lation Code CAN CGA B149 1 The appliance when installed must be electri cally...

Страница 6: ...Requirements IntheCommonwealthofMassachusetts hori zontal terminations installed less than seven 7 feet above the finished grade must comply with the following additional requirements A hard wired ca...

Страница 7: ...raisedplatformcanbeplacedunderneath to prevent cold transfer to the fireplace and into the room It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops MANUFA...

Страница 8: ...rtical Vent Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figures 4 and 5 NOTE See Figure 42 on Page 22 for the exterior wall recess allow...

Страница 9: ...mm minimum G Clearance to inside corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above th...

Страница 10: ...tc a metal or woodbarriercoveringtheentirebottomsurface must be used Wall Finishes Surrounds Mantels NOTE Combustible wall finish materials and or surround materials must not be allowed to encroach th...

Страница 11: ...m SERVICE CLEARANCES Feet meters Front Back Sides 3 feet 0 9 meters Table 5 Figure 10 Unit Parts Identification DETAILED INSTALLATION STEPS The appliance is shipped with all gas controls and component...

Страница 12: ...or rear of the unit using the factory providednailingflanges Installthenailing flanges 8 LibraST 4 LibraPF LibraCL and LibraCR as shown in Figure 12 using the existing screws Position the fireplace w...

Страница 13: ...NO ELBOWS inches millimeters 7 178 130 308 6 1 4 159 A Minimum Framing Stud Size is 2x4 267 289 22 3 4 578 Dimension A Secure Vent 47 1 8 1197 Secure Flex 47 3 4 1213 This dimension can be reduced to...

Страница 14: ...200 37 3 4 959 40 1 4 1023 41 1041 37 940 34 1 8 867 23 1 2 597 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top Stepped to a...

Страница 15: ...ight FIREPLACE SPECIFICATIONS CONTINUED LibraCL Corner Left Figure 20 NOTE Unit has a factory installed vent seal cap and vent cover plate see Figures 22 23 on Page 17 in each flue outlet The vent sea...

Страница 16: ...f valve See Step 7 on Page 31 Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore Certai...

Страница 17: ...such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe Installation of Vent Restrictor A vent restrictor may be needed with this ap...

Страница 18: ...2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9 7...

Страница 19: ...mm Refer to the Effective Vent Length Chart Table 7 on Page 18 for an aid in selecting length combinations Elbows are available in 90 and 45 configura tions Refer to Figure 30 for the SV4 5E45 and SV...

Страница 20: ...outlet One method of support is by utiliz ingfield providedsupportstraps conventional plumber s tape Secure the plumber s tape to theframingmemberswithnailsorscrews Loop the tape around the vent secur...

Страница 21: ...nt STRAIGHT Figure 37 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF vWall...

Страница 22: ...Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D H H...

Страница 23: ...plan the venting so that a joint does not occurintheceilingorroofjoists Allowforelbows as indicated in Figure 30 on Page 18 Maintain a minimum 1 26 mm clearance to combustiblesontheverticalsections Cl...

Страница 24: ...The snorkel cap is designed to be fitted into a basement window box The SVHRK cap is for use with flex vent Theverticaldistancebetweentheinletandoutlet of the cap is 28 711 mm pipe IMPORTANT The vent...

Страница 25: ...n ratios that are smaller are acceptable all the way down to at or near level NOTE SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible f...

Страница 26: ...vent will be required Thistableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Minimum...

Страница 27: ...192 m Max V H H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 47 Side Vent TH...

Страница 28: ...t of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 from the end 3 Pull and extend the inner flexible vent pipe 4 Sli...

Страница 29: ...the right of the valve in the front for optional blower kit See junction box and receptacle outlet as explained in steps 1 11 for B Elec tronic Wiring on this page B Electronic Wiring See Figure 54 NO...

Страница 30: ...label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Junction Box Tab Intact Tab Broken Plug blower into this receptacle n e e r G d...

Страница 31: ...take a few minutes for the line to purge itself of air Once purging is complete the pilot and burner willlightandoperateasindicatedintheinstruc tion manual Subsequent lighting of the appliance will no...

Страница 32: ...t 1 26 mm beyond the hood at all three ports see Figure 57 Replace logs if removed for pilot inspection To light the burner turn ON the remote wall switch and rotate the gas valve control knob counter...

Страница 33: ...ember material 6 Place Volcanic stone Spread volcanic stone evenly over firebox floor 7 Install Vermiculite Place some vermiculite on the firebox floor around the grate the entire bag of vermiculite...

Страница 34: ...ate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide I...

Страница 35: ...og set 55M04 2 6 5 4 1 3 Figure 62 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face...

Страница 36: ...ies and seated firmly Position the door in front of the firebox opening with the bottom of the door held away from the fireplace Figure63 Hookthetopflangeofthe door frame over the top of the firebox f...

Страница 37: ...ensure that the proper flame appearance has been achieved If the following conditions are present adjust accordingly If flame appears weak or sooty adjust the air shutter incrementally to a more open...

Страница 38: ...e 65 Air Shutter Adjusting Rod Orifice Increase Shutter Opening In This Direction Decrease Shutter Opening In This Direction Note Burners are omitted in this view for clarity MAIN BURNER FACTORY SHUTT...

Страница 39: ...ez que l interrupteur contr le le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour limine...

Страница 40: ...ngs come packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 per b...

Страница 41: ...s Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square 1 pack Ref instr 750109M 17M53 SV4 5HGS 12 Termination Guard Hori zontal Square 12 pack Ref instr 750109M 87L02 SV4 5HGS Termination Gu...

Страница 42: ...y the tab on the panel s right end pull the right end of the panel away from the cabinet and then pull the panel diagonally out of the left side cabinet panel slots In the above procedure reverse the...

Страница 43: ...ls Figure 72 illustrates the orifice Always check and verify correct orifice size B Install the burner as shown in Figure 73 When reinstalling the igniter assembly use extreme care to prevent damage a...

Страница 44: ...proximit WARNING Children and adults should be alerted to the hazards of high surfacetemperatureandshould stay away to avoid burns or clothing ignition CARE AND OPERATIONS WARNINGS Burn in Period Dur...

Страница 45: ...t subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou u...

Страница 46: ...ng pilot flame Exercise caution when using products with combustible vapors H I LO W TPTH TP TH P I L O T P I L O T O N i t OFF Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure P...

Страница 47: ...erifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptor...

Страница 48: ...itial use and at least annually by a qualified service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and no...

Страница 49: ...traight out from the unit once the brackets are disengaged Locate the two 2 latches at the top of the controlcompartmentanddisengagethemfrom thedoorframebottomvee flange pullingdown on their handles t...

Страница 50: ...olcanic Stone Spread volcanic stone evenly over firebox floor 6 Install Vermiculite Place some vermiculite on the firebox floor around the grate the entire bag of vermiculite will NOT be used See Figu...

Страница 51: ...ate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide I...

Страница 52: ...og set 55M04 2 6 5 4 1 3 Figure 80 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face...

Страница 53: ...ot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame wil...

Страница 54: ...e is achieved If flame remains blue adjust the air shutter incrementally to a more closed position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON positio...

Страница 55: ...Hearth Products dealer or distributor Normally allpartsshouldbeorderedthroughyour Innovative Hearth Products distributor or dealer Parts will be shipped at prevailing prices at time of order WARRANTY...

Страница 56: ...ceiver may be wall mounted or placed in the valve compartment Wall Thermostat Wall surface mounted Thermostat or manual ON OFF operation Large LCD screen to display room and set temperature in F and C...

Страница 57: ...FWSK OFF ONWallSwitchKit ACCESSORY COMPONENTS CONTINUED H0779 Top Vent H0778 Top Vent H0780 H0781 Top Vent H0779 Rear Vent H0778 Rear Vent H0780 H0781 Rear Vent Panel Liner Kits Model No Catalog No Mo...

Страница 58: ...on can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in pla...

Страница 59: ...tely call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your s...

Страница 60: ...atement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qua...

Страница 61: ...le Set thermostat to desired setting Turn wall on off switch unit mounted on off switch or remote control switch ON 11 Close control compartment OPERATING INSTRUCTIONS 1 If applicable Set the thermost...

Страница 62: ...rmostat la temp rature la plus basse Tournez e c n a t s i d e l r t n o c e l u o t i n u l r u s r u e t p u r r e t n i l e l a r u m r u e t p u r r e t n i l OFF 2 Coupez l alimentation lectrique...

Страница 63: ...ystem troubleshooting should only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 11 on Page 14 Check burner ori...

Страница 64: ...age Transformer Limit Controller Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected M...

Страница 65: ...1 9 Gasket Venturi Tube Mounting 43K85 1 1 1 1 10 Venturi Tube Arm 42M80 1 1 1 1 11 Switch Rocker 80L41 1 1 1 1 12 Air Shutter Adjustment Rod H6321 1 1 1 1 13 Flexline Gas Conductor 93L32 1 1 1 1 14...

Страница 66: ...to obtain any of these parts REPLACEMENT PARTS LIST CONTINUED WARNING Never use substitute materials Use of non approved parts can result in poor performance and safety hazards GAS CONTROLS HONEYWELL...

Страница 67: ...od or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The...

Страница 68: ...Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time with out notice in design materials specifications prices...

Отзывы: