background image

Astria.us.com

126882-01B

22

1.  STOP! Read the safety information, 

Page 20

.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Press in and turn control knob clockwise 

 to the OFF position

 (see Figure 31)

.

4. Wait 

fi ve (5) minutes to clear out any gas. 

Then smell for gas, including near the 
fl oor. If you smell gas, STOP! Follow “B” 
in the safety information, 

Page 20

. If you 

don’t smell gas, go to the next step.

5.  Press in and turn control knob counter-

clockwise 

 to the PILOT position. 

Press in control knob for fi ve (5) seconds 

(see Figure 29).

 

NOTE: You may be running this fi replace 
for the fi rst time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system.

6.  With control knob pressed in, press and 

release igniter button. This will light pilot. 
The pilot is attached to the front burner. If 
needed, keep pressing igniter button until 
pilot lights.

 

NOTE: If pilot does not stay lit, contact a 
qualifi ed service person or gas supplier 
for repairs. Until repairs are made, light 
pilot with match. To light pilot with match, 
see Manual Lighting Procedure. 

7.  Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds, 
release control knob.
• If control knob does not pop out when 

released, contact a qualified service 
person or gas supplier for repairs.

 

NOTE: If pilot goes out, repeat steps 4 
through 8.

8.  Slightly push in and turn control knob 

counterclockwise 

 to the ON position.

9. Set fl ame adjustment knob to any level 

between HI and LO.

Figure 29 - Control Knob and Igniter 

Button Location (Shown as Supplied - 

No Control Options)

Piezo 
Igniter 
Button

Control 
Knob

Flame 
Adjustment 
Knob

Figure 30 - Propane/LP Gas Pilot

Igniter 
Electrode

Pilot 
Burner

Figure 31 - Natural Gas Pilot

Igniter 
Electrode

Pilot Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.  Turn control knob clockwise 

 to the 

OFF position.

2. 

If Using Optional Hand-Held Remote:

 

Set selector switch in the OFF position to 
prevent draining battery.

3.  Close equipment shutoff valve 

(see Fig-

ure 16, Page 15).

 WARNING: Make sure re-

mote sensor selector switch is 
in the OFF position when you 
are away from home for long 
periods of time.

MANUAL LIGHTING

PROCEDURE

1.  Follow steps 1 through 5 under 

Lighting 

Instructions

.

2.  Press control knob and light pilot with 

match.

3.  Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds, 
release control knob. Now follow steps 8 
and 9 under 

Lighting Instructions

.

OPERATION 

Continued

REMOTE-READY MODELS

10. To leave pilot lit and shut off burners only, 

turn control knob clockwise to PILOT posi-
tion. If using optional hand-held remote, 
use remote control manual OFF button.

 CAUTION: Do not try to ad-

just heating levels by using the 
equipment shutoff valve.

Содержание Gamma26ZMN

Страница 1: ...uate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual PFS US Report No F09 123 WARNING FIRE OR EXPLOSION HAZARD Failure to f...

Страница 2: ...his manual for reference It is your guide to safe and proper operation of this fireplace WARNING FIRE EXPLOSION AND ASPHYXIATION HAZARD Improperadjustment alteration service maintenance orinstallation...

Страница 3: ...o prevent children from turning on burners with remote Youmustoperatethisheaterwiththe fireplace screen and hood in place before running heater The fireplace screenshallhaveopeningsforintro duction of...

Страница 4: ...as indicated on the rating plate This appliance is not convertible for use with other gases off If heated the vapors from these products may create a white powder residue within burner box or on adjac...

Страница 5: ...care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANS Z223 1 NFPA 54 Firebox must be electrically grounded in accordance with the National...

Страница 6: ...plastic straps to remove log from firebox cavity Set log aside 3 An optional blower is available See Ac cessories Page 30 Install optional blower now Follow installation instructions pro vided with b...

Страница 7: ...d door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of the t...

Страница 8: ...nt gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors Example Gas water appliance __________ Btu Hr Gas firebox logs _________ Btu Hr Total _________ Btu Hr 4...

Страница 9: ...ning unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 You can als...

Страница 10: ...fireplace make sure you have the items listed below external regulator supplied by installer for propane LP units only piping check local codes sealant resistant to propane LP gas equipment shutoff v...

Страница 11: ...tible material and wall should follow diagram in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall This com bustible material must b...

Страница 12: ...and top edge of the firebox Combustible materials should never overlap the firebox front facing Figure 8 Rough Opening for Installing in Corner Figure 7 Rough Opening for Installing in Wall 435 16 305...

Страница 13: ...ionalproductstandard Follow all minimum clearances shown in this manual INSTALLATION Continued Figure 10 Minimum Mantel Clearances for Built In Installation Mantel Shelf Side of Firebox NOTICE Ifyouri...

Страница 14: ...ne pressure must be no greater than 14 of water If gas line pressure is higher heater regulator damage could occur CAUTION Neverconnectpro pane LP fireplace directly to the propane LPsupply Thisfirepl...

Страница 15: ...enchwhenconnectingittogas pipingand orfittings Thermostat Controlled Models Only CAUTION Avoid damage to gas control Hold gas control with wrench when connecting it to gas piping and or fittings Remot...

Страница 16: ...as or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or propane LP supply to...

Страница 17: ...ct this thermostat to any electrical source Electrical shock and or fire hazard will occur 1 Remove jumper wire from control valve see Figure 19 2 Connect one terminal of 25 ft wire to the TH terminal...

Страница 18: ...e from control valve see Figure 19 Page 16 2 Connect one terminal of 25 ft wire to the TH terminal on the control valve Con nect other terminal to the THTP terminal on control valve See Figure 21 3 Ro...

Страница 19: ...give off a paper burning smell Open window to vent smell Operate fireplace on HI position to burn off odor This will only last a few hours 1 STOP Read the safety information start ing in column 1 FOR...

Страница 20: ...ntrol Knob In The OFF Position Igniter Button Control Knob Figure 26 Natural Gas Pilot Thermocouple Igniter Electrode Pilot Burner Figure 27 Propane LP Gas Pilot Thermocouple Igniter Electrode Pilot B...

Страница 21: ...few hours WARNING Burner will come on automatically within one min ute when control valve is in the ON position after the pilot is lit NOTE Your fireplace and thermostat blower will not turn on and of...

Страница 22: ...act a qualified service person or gas supplier for repairs NOTE If pilot goes out repeat steps 4 through 8 8 Slightly push in and turn control knob counterclockwise to the ON position 9 Set flame adju...

Страница 23: ...n the battery Figure 32 Setting the Selector Switch Control Knob and Flame Adjustment Knob for Remote Operation Flame Adjustment Knob Control Knob Selector Switch in Remote Position Optional Remote Co...

Страница 24: ...the flame will be orange for approximately one hour until the log cures If burner flame pattern is incorrect as shown in Figure 36 turn fireplace off see To Turn Off Gas to Ap pliance Page 19 for The...

Страница 25: ...ow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet CLEANING AND MAINTENANCE Continued LOG SET If you remove one piece log set for clean ing refer...

Страница 26: ...in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect igniter cable 2 Free ignite...

Страница 27: ...ODS pilot lights keep control knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natura...

Страница 28: ...control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observeminimuminstallation clearances see...

Страница 29: ...ee Warning statement at top of Page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of Page 2 Control valve defective 1...

Страница 30: ...ICE All accessories may not be available for all fireplace models SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition appliance will not produce speci...

Страница 31: ...ows appliance to be operated in a manually thermostatically or programmed controlled mode RECEIVER AND HAND HELD ON OFF Cat No F2236 Model RCKIT4001 For remote ready models only Allows appliance to be...

Страница 32: ...titute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards 8 8 14 14 14 14 14 14 14 1 9 9 16 17 6 3 11 12 13 11 15 16 18 16 16 16 16 16 16 2 5 16...

Страница 33: ...n Hinge 1 13 J3870 Left Pin Hinge 1 14 J3629 Screw HWH SHLDR AB 10 x 0 63 14 15 J4492 Remote Blower Bracket 1 16 J1955 Screw HWH AB 10 16 x 0 38 35 17 J4665 Box Cover 1 18 J4522 Support Bracket 1 19 J...

Страница 34: ...Astria us com 126882 01B 34 PARTS THERMOSTAT MODELS GAMMA26ZTP AND GAMMA26ZTN 8 7 5 6 6 12 2 19 18 15 16 9 9 17 11 14 3 13 20 9 1 21 10...

Страница 35: ...8 x 0 38 2 9 J1955 Screw HWH AB 10 16 x 0 38 10 10 Chamber Floor 1 11 J3550 Male Fitting 1 12 J3595 Gas Regulator LP 1 J3596 Gas Regulator NG 1 13 J4219 Inlet Tube 1 14 J3745 Control Bracket 1 15 J358...

Страница 36: ...Astria us com 126882 01B 36 PARTS REMOTE READY MODELS GAMMA26ZMN AND GAMMA26ZMP O F F P I L O T O N H I L O 16 15 15 16 12 12 11 9 9 9 10 5 17 18 13 19 2 1 3 14 7 6 8 20 Natural Gas Only 9 21 22...

Страница 37: ...t Tube 1 8 J3558 ODS Nut 2 9 J1955 Screw HWH AB 10 16 x 0 38 10 10 Chamber Floor 1 11 J4464 Piezo Bracket 1 12 J3746 Piezo Igniter with Palnut Fastener 1 13 J3725 Flexible Connector 1 14 J3569 Igniter...

Страница 38: ...________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________...

Страница 39: ...e ood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use...

Страница 40: ...uses Dealer name P126882 01 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your...

Отзывы: