Astria Fireplaces EOS18MN Скачать руководство пользователя страница 5

Astria.us.com

126854-01F

5

Six 

Piece Log 

Set

Piezo 

Igniter

Flame 

Adjustment 

Knob

Control 

Knob

Base 

Assembly

Left

Side

Right

Side

Front

LOCAL CODES

Install and use appliance with care. Follow all local codes. In the 

absence of local codes, use the latest edition of 

The National Fuel 

Gas Code, ANSI Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

25 West 43rd Street, 4th floor

New York, NY 10036

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA 02169-7471

NOTE

: Where listed vented decorative logs are required, thermostat 

operation is not permitted.

UNPACKING

1.  Remove logs and heater base assembly from cartons.

 

NOTE

: Do not pick up heater base assembly by burners. This 

could damage heater. Always handle base assembly by grate.

2.  Remove all protective packaging applied to logs and appliance 

for shipment.

3.  Check appliance for any shipping damage. If appliance is dam-

aged, promptly inform dealer where you purchased the appliance.

 CAUTION: Do not remove the data plates from the 

grate assembly. The data plates contain important 

warranty and safety information.

COMMONWEALTH OF MASSACHUSETTS

 

REQUIREMENTS

These appliances are approved for installation in the US state of 

Massachusetts if the following additional requirements are met:

• Un-vented Room Heaters shall be installed in accordance with 

527 CMR 30.

•  Installation and repair must be done by a plumber or gas fitter 

licensed in the Commonwealth of Massachusetts.

•  The flexible gas line connector used shall not exceed 36 inches 

(92 centimeters) in length.

•  The individual manual shut-off must be a T-handle type valve.

• Unvented appliances may NOT be installed in bedrooms or 

bathrooms.

• A working smoke detector must be installed in the area where 

vent-free appliances are installed.

Seller of unvented propane or natural gas-fired supplemental 

room heaters shall provide to each purchaser a copy of 527 CMR 

30 upon sale of the unit.

PRODUCT IDENTIFICATION

Figure 1 - Product Identification

OPERATION

This heater is clean burning. It requires no outside venting. There 

is no heat loss out a vent or up a chimney. Heat is generated by 

both realistic flames and glowing coals. This heater is designed for 

vent-free operation with flue damper closed. It has been tested and 

approved to ANSI Z21.11.2 standard for unvented heaters. State and 

local codes in some areas prohibit the use of vent-free heaters. This 

heater may also be operated as a vented decorative (ANSI Z21.60) 

product by opening the flue damper.

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensing (ODS) 

safety shutoff system. The ODS/pilot is a required feature for vent-

free room heaters. The ODS/pilot shuts off the heater if there is not 

enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo igniter. This system requires no matches, 

batteries or other sources to light heater.

PRODUCT FEATURES

Содержание EOS18MN

Страница 1: ...alled Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instructions Unven...

Страница 2: ...prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale n...

Страница 3: ...uld be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool before touching...

Страница 4: ...ot follow the instructions in Cleaning and Maintenance Page 19 11 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may c...

Страница 5: ...ith 527 CMR 30 Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimet...

Страница 6: ...applicable local codes Read the following instructions to en sure proper fresh air for this and other fuel burning appliances in your home Confined and Unconfined Space The National Fuel Gas Code ANS...

Страница 7: ...all connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion a...

Страница 8: ...rmanently closed at time of appliance installation WARNING Seal any fresh air vents or ash clean out doors located on floor or wall of fireplace If not draftingmaycausepilotoutageorsooting Useaheat re...

Страница 9: ...ble material is less than 12 you must install the fireplace hood accessory for all models See Figure 5 for minimum clearances If Using Mantel You must have noncombustible material s above the fireplac...

Страница 10: ...en Using a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figur...

Страница 11: ...ue opening will be maintained at all times IMPORTANT Make sure the heater burners are level If heater is not level heater will not work properly Installation Items Needed hardware package provided wit...

Страница 12: ...ch For propane LP units the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If...

Страница 13: ...y not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting it to gas pip ing and or fittings WARNING Test all gas piping and connections internal and external...

Страница 14: ...sediagramsorfailuretouseonlyparts specifically approved with this heater may result in property damage or personal injury CAUTION After installation and periodically thereafter check to ensure that no...

Страница 15: ...19 Front log has cut outs for the fingers of the grate to fit into Figure 20 Installing Left Center and Right Crossover Logs Right Crossover Log Left Crossover Log Center Crossover Log Square Peg on R...

Страница 16: ...ont Log Rear Log Log Notch Figure 25 Installing Middle Log Figure 26 Installing Top Left Log Figure 27 Final assembly 5 Place the top middle log onto the rear middle logs as shown in Figure 25 Make su...

Страница 17: ...obstructions across opening of fireplace Youmustoperatethisheaterwithafireplacescreen inplace Makesurefireplacescreenisclosedbefore running heater NOTICE During initial operation of new heater burn in...

Страница 18: ...h selector switch if optional re mote control is used to the ON position to light burners NOTE AUTO is only functional when using GWMT1 or GWMS2 optional accessories 11 Set flame adjustment knob to an...

Страница 19: ...amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes...

Страница 20: ...es should be open with yellow flame present All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame prese...

Страница 21: ...pilot is clogged 7 Gas regulator setting is not correct 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT posi tion 4 Co...

Страница 22: ...ntrol knob to HI position when burners are cold 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice s 1 TurncontrolknobtoLOpositionandletwarm up for a min...

Страница 23: ...ilable 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance...

Страница 24: ...O MODEL F0155 EOS18MN F0156 EOS18MP WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts specifically approved with this heater may result in property damage or...

Страница 25: ...ce 111 1 J3617 Orifice 073 1 7 J3635 Pilot Tube 1 J3637 Pilot Tube 1 8 J3654 Pilot Regulator 1 9 J3660 Tube 1 10 J3830 Pilot ODS LP 1 J3831 Pilot ODS NG 1 11 J3836 Gas Valve NG 1 J3837 Gas Valve LP 1...

Страница 26: ...1 5 J6112 Center Crossover Log 1 J6118 Center Crossover Log 1 6 J6113 Right Front Crossover Log 1 J6119 Right Front Crossover Log 1 C a r o l i n a O a k 1 8 C a r o l i n a O a k 2 4 4 5 1 3 6 2 CHE...

Страница 27: ...mplete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at ti...

Страница 28: ...ve fireplace Fits open ings 28 to 48 wide F1764 GA6050 Hood Adjustable Flat Black DECORATIVE ASH BED CONTROL COVER KIT F1759 CDABKA 6 KIT DECORATIVE ASH BED 6PK F0246 CDABKA Decorative Ash Bed Control...

Страница 29: ...L KIT For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is programmable for your convenience and has a large bright LCD Touch...

Страница 30: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Страница 31: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions prov...

Страница 32: ...al distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126854 01 Rev F 03 2019 1769 East Lawrence Street Russellville AL 35654 Astria us com Record the foll...