Astria Fireplaces EOS18MN Скачать руководство пользователя страница 27

Astria.us.com

126854-01F

27

LOG SET MODELS: CAROLINAOAK18 AND CAROLINAOAK24 LOGS 
(CAROLINA OAK™)

PARTS

  

Continued

5

7

3

1

2

6

4

KEY

NO.

PART NUMBERS

DESCRIPTION

QTY

Carolina

Oak18

ID #

Carolina

Oak24

ID #

1

F2722

CO-11

F2723

CO-04 Bottom Back Log

1

2

F2724

CO-10

F2725

CO-03 Bottom Middle Log

1

3

F2726

CO-08

F2727

CO-01 Bottom Front Left Log 1

4

F2728

CO-09

F2729

CO-02 Bottom Front Right Log 1

5

F2730

CO-12

F2731

CO-05 Top Left Log

1

6

F2732

CO-07

F2733

CO-07 Top Right Log

1

7

F2734

CO-06

F2735

CO-06 Top Middle Log

1

SPECIFICATIONS

EOS18MN

•  Rating: 25,000/36,000 Btu/hr
•  Gas Type: Propane/LP
•  Ignition: Piezo
•  Manifold Pressure: 8.0" W.C.
•  Inlet Supply Pressure (inches of water):  

Maximum - 14" W.C., Minimum - 11" W.C.

EOS18MP

•  Rating: 25,000/36,000 Btu/hr
•  Gas Type: Natural
•  Ignition: Piezo
•  Manifold Pressure: 3.5" W.C.
•  Inlet Supply Pressure (inches of water):  

Maximum - 10.5" W.C., Minimum - 5" W.C.

WIRING DIAGRAM

Thermopile

REPLACEMENT PARTS

 CAUTION: Label all wires prior to disconnection 

when servicing controls. Wiring errors can cause 

improper and dangerous operation. Verify proper 

operation after servicing.

See 

Pages 24-27

 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.

Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.

NEVER USE SUBSTITUTE MATERIALS. USE OF NON-APPROVED 

PARTS CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZ-

ARDS.

When ordering repair parts, always give the following information:

1. The model number of the appliance.

2. The serial number of the appliance.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the appliance.

If you encounter any problems or have any questions concerning 

the installation or application of this appliance, please contact your 

dealer.

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  appliance will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local 

propane/LP or natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns. When contacting your dealer please have your model 

and serial numbers of your appliance ready. You can also visit our 

web site at Astria.us.com.

Содержание EOS18MN

Страница 1: ...alled Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instructions Unven...

Страница 2: ...prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale n...

Страница 3: ...uld be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool before touching...

Страница 4: ...ot follow the instructions in Cleaning and Maintenance Page 19 11 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may c...

Страница 5: ...ith 527 CMR 30 Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimet...

Страница 6: ...applicable local codes Read the following instructions to en sure proper fresh air for this and other fuel burning appliances in your home Confined and Unconfined Space The National Fuel Gas Code ANS...

Страница 7: ...all connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion a...

Страница 8: ...rmanently closed at time of appliance installation WARNING Seal any fresh air vents or ash clean out doors located on floor or wall of fireplace If not draftingmaycausepilotoutageorsooting Useaheat re...

Страница 9: ...ble material is less than 12 you must install the fireplace hood accessory for all models See Figure 5 for minimum clearances If Using Mantel You must have noncombustible material s above the fireplac...

Страница 10: ...en Using a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figur...

Страница 11: ...ue opening will be maintained at all times IMPORTANT Make sure the heater burners are level If heater is not level heater will not work properly Installation Items Needed hardware package provided wit...

Страница 12: ...ch For propane LP units the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If...

Страница 13: ...y not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting it to gas pip ing and or fittings WARNING Test all gas piping and connections internal and external...

Страница 14: ...sediagramsorfailuretouseonlyparts specifically approved with this heater may result in property damage or personal injury CAUTION After installation and periodically thereafter check to ensure that no...

Страница 15: ...19 Front log has cut outs for the fingers of the grate to fit into Figure 20 Installing Left Center and Right Crossover Logs Right Crossover Log Left Crossover Log Center Crossover Log Square Peg on R...

Страница 16: ...ont Log Rear Log Log Notch Figure 25 Installing Middle Log Figure 26 Installing Top Left Log Figure 27 Final assembly 5 Place the top middle log onto the rear middle logs as shown in Figure 25 Make su...

Страница 17: ...obstructions across opening of fireplace Youmustoperatethisheaterwithafireplacescreen inplace Makesurefireplacescreenisclosedbefore running heater NOTICE During initial operation of new heater burn in...

Страница 18: ...h selector switch if optional re mote control is used to the ON position to light burners NOTE AUTO is only functional when using GWMT1 or GWMS2 optional accessories 11 Set flame adjustment knob to an...

Страница 19: ...amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes...

Страница 20: ...es should be open with yellow flame present All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame prese...

Страница 21: ...pilot is clogged 7 Gas regulator setting is not correct 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT posi tion 4 Co...

Страница 22: ...ntrol knob to HI position when burners are cold 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice s 1 TurncontrolknobtoLOpositionandletwarm up for a min...

Страница 23: ...ilable 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance...

Страница 24: ...O MODEL F0155 EOS18MN F0156 EOS18MP WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts specifically approved with this heater may result in property damage or...

Страница 25: ...ce 111 1 J3617 Orifice 073 1 7 J3635 Pilot Tube 1 J3637 Pilot Tube 1 8 J3654 Pilot Regulator 1 9 J3660 Tube 1 10 J3830 Pilot ODS LP 1 J3831 Pilot ODS NG 1 11 J3836 Gas Valve NG 1 J3837 Gas Valve LP 1...

Страница 26: ...1 5 J6112 Center Crossover Log 1 J6118 Center Crossover Log 1 6 J6113 Right Front Crossover Log 1 J6119 Right Front Crossover Log 1 C a r o l i n a O a k 1 8 C a r o l i n a O a k 2 4 4 5 1 3 6 2 CHE...

Страница 27: ...mplete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at ti...

Страница 28: ...ve fireplace Fits open ings 28 to 48 wide F1764 GA6050 Hood Adjustable Flat Black DECORATIVE ASH BED CONTROL COVER KIT F1759 CDABKA 6 KIT DECORATIVE ASH BED 6PK F0246 CDABKA Decorative Ash Bed Control...

Страница 29: ...L KIT For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is programmable for your convenience and has a large bright LCD Touch...

Страница 30: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Страница 31: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions prov...

Страница 32: ...al distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126854 01 Rev F 03 2019 1769 East Lawrence Street Russellville AL 35654 Astria us com Record the foll...

Отзывы: