Astria.us.com
126854-01F
14
Figure 15 - Equipment Shutoff Valve
Figure 16 - Checking Gas Joints (Propane/LP Model Shown)
Gas Control Valve
Location
Propane/LP
Supply Tank
Equipment Shutoff
Valve
Figure 17 - Checking Gas Joints (Natural Gas Only)
Gas Meter
Gas Control Valve
Location
Equipment Shutoff
Valve
Open
Closed
Equipment
Shutoff Valve
Figure 18 - Installing Rear and Middle Logs
Rear Log
Burner
Pin for
Hole in
Bottom
of Log
Center Log
CAROLINAOAK18 AND CAROLINAOAK24
It is very important to install these logs exactly as instructed. Do not
modify logs. Only use logs supplied with heater.
1. Place rear log onto base. Holes in bottom of log must seat over
pins on base as shown in
Figure 18
.
2. Place center log onto base. Holes in bottom of log must seat
over pins on base as shown in
Figure 18
.
WARNING: Failure to position the parts in accor-
dance with these diagrams or failure to use only parts
specifically approved with this heater may result in
property damage or personal injury.
CAUTION: After installation and periodically
thereafter, check to ensure that no flame comes in
contact with any log. With the heater set to HI, check
to see if flames contact any log. If so, reposition logs
according to the log installation instructions in this
manual. Flames contacting logs will create soot.
INSTALLING LOGS
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve
(see
Figure 17
).
2. Open main gas valve located on or near gas meter for natural
gas or open propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to gas control
(see
Figures 16 and 17
)
. Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater
(see Operation,
Page 17
).
Check all other internal
joints for leaks.
7. Turn off heater
(see To Turn Off Gas to Appliance,
Page 18
).
INSTALLATION
Continued