Astria Fireplaces Aries Series Скачать руководство пользователя страница 1

 -  Do not store or use gasoline or other fl ammable 

vapors and liquids in the vicinity of this or any 
other appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use 

any phone in your building. 

•  Leave the building immediately.
•  Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instruc-
tions. 

•  If you cannot reach your gas supplier, call the 

fi re department.

 -  Installation and service must be performed by 

a qualifi ed installer, service agency or the gas 
supplier.

       

WARNING:

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could 
result in serious injury, death, or property damage.

        AVERTISSEMENT:

RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité 
pourrait d’entraîner des blessures graves, la mort 
ou des dommages matériels.

 -   Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs ou liquides infl ammables dans le voisinage 
de cet appareil ou de tout autre appareil.

 -   QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir 

des téléphones se trouvant dans le bâtiment où 
vous trouvez. 

•  Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 
fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

  -    L’installation et l’entretien doivent être assurés par 

un installateur ou un service d’entretien qualifi é 
ou par le fournisseur de gaz.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future 
reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour 
consultation ultérieure.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) 
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas 
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit 
is used.

Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements 
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque 
signalétique.  Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.

Installation and Operation Instructions

Models

C

US

Report No. F13-094

Ce manuel est disponible en francais, simplement en 
faire la demande. Numéro de la pièce 900004-03.

P/N 900004-01   REV. J   03/2017

Aries™ Series Direct-Vent Fireplaces

Aries33TMN
Aries33TMP

Aries33TEN
Aries33TEP

AriesCD33TMN
AriesCD33TMP

AriesCD33TEN
AriesCD33TEP

AriesCD33RMN
AriesCD33RMP

AriesCD33REN
AriesCD33REP

AriesCD35TMN
AriesCD35TMP

AriesCD35TEN
AriesCD35TEP

Aries33RMN
Aries33RMP

Aries33REN
Aries33REP

Aries35TMN
Aries35TMP

Aries35TEN
Aries35TEP

Aries35RMN
Aries35RMP

Aries35REN
Aries35REP

AriesCD35RMN
AriesCD35RMP

AriesCD35REN
AriesCD35REP

Aries40TMN
Aries40TMP

Aries40TEN
Aries40TEP

AriesCD40TMN
AriesCD40TMP

AriesCD40TEN
AriesCD40TEP

Aries40RMN
Aries40RMP

Aries40REN
Aries40REP

AriesCD40RMN
AriesCD40RMP

AriesCD40REN
AriesCD40REP

Aries45DMN
Aries45DMP

Aries45DEN
Aries45DEP

AriesCD45DMN
AriesCD45DMP

AriesCD45DEN
AriesCD45DEP

Traditional

Contemporary

P900004-01

Содержание Aries Series

Страница 1: ...nce CONSUMER Retain this manual for future reference Installateur Laissez cette notice avec l appareil Consommateur Conservez cette notice pour consultation ultérieure This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate Th...

Страница 2: ...IDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla vidrio c...

Страница 3: ...s si se toca Mantenga a los niños alejados de la chimenea en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente calient...

Страница 4: ...to Combustibles 14 Wall Finishes Surrounds Mantels 15 Installation Preparation 15 Installation Installation Sequence 16 Construct the Fireplace Framing 16 Prepare the Fireplace Top Spacers 18 Route the Gas Supply Line to the Fireplace 18 Vent System Preparation 20 Install the Vent Restrictor if necessary 21 Connecting The Vent Pipe 22 Vent Section Length Table 23 Install the Vent System 24 Complet...

Страница 5: ... des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou p...

Страница 6: ...per installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a qualified profession...

Страница 7: ...ations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an alternate primary heat source when installed in a dwelling ...

Страница 8: ...ept clean Remarqué L installation et la réparation devrait être confiées à un technicien qualifié L appareil devrait faire l objet d une inspection par un technicien professionnel avant d être utilisé et au moins une fois l an par la suite Des nettoyages plus fréquents peuvent être nécessaires si les tapis la literie et cetera produisent une quantité importante de pous sière Il est essentiel que l...

Страница 9: ...essure Fuel Pressure Natural Gas 3 5 WC 0 87 kPa Propane 10 0 WC 2 49 kPa Table 4 Manifold Gas Supply Pressure Test gauge connections are provided on the front of the millivolt and electronic gas control valve identified IN for the inlet and OUT for the manifold side The control valves have a 3 8 10 mm NPT thread inlet and outlet side of the valve Figures 1 and 2 Figure 1 Millivolt Gas Valve Figur...

Страница 10: ...d shall not exceed 36 914 mm in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts horizontal terminations installed less than seven 7 ft above the finished grade must comply with the following additional requirements A hard wired carbon monoxide detector with an alarm and battery back up must be instal...

Страница 11: ...In selecting the location the aesthetic and functional use of the fireplace are primary concerns However vent system routing to the exterior and access to the fuel supply are also important Due to high temperatures the fireplace should be located out of traffic and away from furniture and draperies En raison des températures élevées l appareil devrait être installé dans un endroit où il y a peu de...

Страница 12: ...mum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 25 4 mm minimum clearance to combustibles Table 6 Termination Heights for Vents above Flat or Sloped Roofs NFPA 54 ANSI Z223 1 Gas Vent Rule Horizontal Vent Termination Clearances The horizontal vent termination must have a minimum of 6 152 mm cle...

Страница 13: ...nonmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm for fireplaces 10 000 Btu h 3 kW 12 300 mm for fireplaces 10 000 Btu h 3 kW K Clearance to a mechanical air supply inlet 36 910 mm above if within...

Страница 14: ... full width and depth of the unit The fireplace may be located on or near conventional construction materials However if installed on combustible materials such as carpeting vinyl tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Hearth Extension A hearth extension is not require...

Страница 15: ...n combustible materials may be installed at any height above the fireplace opening However do not allow anything to hang below the fireplace hood Minimum clearance requirements include any projections such as shelves window sills mantels etc above the fireplace NOTE To avoid heat related finish damage we recommend the use of high temperature paint rated 175 F or higher on the underside of the mant...

Страница 16: ...y Proper Fireplace Operation Page 40 Finishing 14 Optional Install the Firebox Liners Page 41 15 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers Page 41 16 Contemporary Fireplaces Install the Glass Media Page 41 17 Install the Glass Door Page 41 18 Adjust the Air Shutter to Ensure Proper Flame Appearance Page 41 19 Install the Hood Page 43 20 Reinstall the Included Barrie...

Страница 17: ...nstallation with Horizontal Termination Model A B C D E F G 33 Models 33 3 4 857 mm 51 1 4 1302 mm 36 1 4 921 mm 25 5 8 651 mm 12 1 8 308 mm 5 1 2 140 mm 14 1 2 368 mm 35 Models 35 3 8 899 mm 59 1 2 1511 mm 42 1 8 1070 mm 30 1 4 768 mm 14 1 4 362 mm 6 5 8 168 mm 18 457 mm 40 Models 40 3 8 126 mm 63 7 8 1622 mm 45 3 8 1153 mm 33 1 4 845 mm 15 7 8 403 mm 8 1 2 216 mm 18 457 mm 45 Models 45 3 8 1153 ...

Страница 18: ...aming Pipe coupling recommended 5 1 4 140 mm 3 77 mm Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code NFPA 54 latest edition USA or CAN CGA B149 1 latest edition Canada The gas supply line should not be connected to the appliance until step 12 Co...

Страница 19: ...e 33 5 Install the blower control switch according to its included instructions 6 Place the Fireplace in the Framing and Secure NOTE Nailing flanges combustible members and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1 2 clearance to combustible requirements for the firebox outer wrapper NOTE Combustible framing may be in direct contact with the nailing flange...

Страница 20: ...ical Baffle from top retain screws but discard baffle Reinstall screws to seal holes after vertical baffle is removed Discard the vertical baffle Step 8 Remove the 2 screws holding the block off plate and gasket to top vent flue Retain screws as they will be re used Step 9 Remove the 4 screws around the rear vent and use to Re install block off plate and gasket over the rear vent flue Step 10 Usin...

Страница 21: ...zontal run 60 ft Maximum vertical run 60 1 9 25 Horizontal Distance ft Vertical Height ft Vertical Height ft 2 5 Elbow 5 10 15 Base wing Base 6 ft Minimum vertical run 6 ft Minimum vertical run U Shaped Vent Restrictor Inner Fireplace Collar Appliance Top Vent Outlet U SHAPED VENT RESTRICTOR APPLIANCE REAR VENT OUTLET INNER FIREPLACE COLLAR Inner Fireplace Collar Appliance Rear Vent Outlet U Shape...

Страница 22: ... x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 17 Where required a telescopic vent section SV4 5LA may be used to provide the installer with an option to install in tight and confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable location or will not build up to the required length The SV4...

Страница 23: ...186 15 5 0 0 0 0 4 4 196 5 16 375 0 1 0 0 4 5 207 17 25 0 0 0 6 0 6 211 5 17 625 1 0 0 6 0 7 217 5 18 125 0 1 0 6 0 7 229 5 19 125 0 0 1 6 0 7 232 5 19 375 0 0 0 0 5 5 241 5 20 125 0 0 0 7 0 7 246 20 5 1 0 0 7 0 8 Nominal Section Length in 6 12 24 36 48 Total Qty Net Section Length in 4 5 10 5 22 5 34 5 46 5 Height of Vent Number of Vent Sections in ft 252 21 0 1 0 7 0 8 276 23 0 0 0 8 0 8 279 23 ...

Страница 24: ...djacent walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide to follow is the gas vent rule Table 6 The following figures and their associated vertical vent tables illustrate the various configurations that are possible for use with these fireplaces Secure Vent pipe...

Страница 25: ... Install firestop spacer at ceiling When using Secure Vent use SV4 5VF firestop spacer at ceiling joists when using Secure Flex use SF4 5VF firestop spacer If there is living space above the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent secti...

Страница 26: ...p and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 12 Install the storm collar Install the storm collar supplied with the flashing over the vent flashing joint Figure 23 Loosen the storm collar screw Slide collar down until it meets the top of the flashing Tighten the adjusting screw Apply non combustible caulking or mastic around the cir...

Страница 27: ... elbow is the only vertical component in the system WARNING Do NOT join separate sections of concentric flexible vent pipe Figure 25 Top Vent Straight Table 17 Rear Vent One 90 Elbow Ceiling firestop spacer SV4 5VF When using Secure Flex use ceiling firestop spacer SF4 5VF 60 ft 18 3 m maximum H Maximum V Minimum feet meters feet meters 2 0 610 1 0 305 4 1 219 2 0 610 6 1 829 3 0 914 8 2 438 4 1 2...

Страница 28: ...h more than 6 ft of vertical rise See Page 21 for more information If 25 ft of H horizontal vent run is needed then 5 ft straight section minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 25 ft Minimum 6 ft and maximum of 60 ft of vertical venting H 8 ft 2 4 m maxim...

Страница 29: ...e minimum clearances for combustibles Page 24 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 11 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 308 mm inside dimensions about this center 3 Frame the ceiling opening If the vertical route is to penetrate a ceiling use plumb line to locate the center above the fireplace Cut and or frame an opening ...

Страница 30: ...7 13 Install the firestop spacer at the exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the exterior side of the framing long side up with the 4 spacer clearance at the top Figure 27 and nail into place NOTE The firestop spacer may also be installed over the opening at the interior side of the framing 14 Install th...

Страница 31: ...f Framing Last Vent Section Use Telescopic Vent Section SV4 5LA If Necessary Adaptor SV4 5RCH Use silicone caulking to seal the top and sides of the termination up to the underlayment stucco or masonry wall surface Caulk Caulk For thicknesses greater than 9 1 4 235 mm see Table 21 Figure 28 Venting Connection and Exterior Wall Recessing of the Horizontal Compact Termination SV4 5HTKCT See Table 11...

Страница 32: ...es through a combustible wall WARNING Do not join separate sections of concentric flexible vent together Table 22 Rear Vent No Elbows Compact termination SV4 5HTKCT shown See Table 21 as an aid in venting component selection for a particular range of exterior wall thicknesses Note H is horizontal distance from rear of unit to outer wall surface Note On 45 models only 1 vertical rise is required wh...

Страница 33: ...for more information Compact termination SV4 5HTKCT shown See Table 21 as an aid in venting component selection for a particular range of exterior wall thicknesses If 25 ft of H horizontal vent run is needed then 5 ft minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run o...

Страница 34: ...lex use ceiling firestop spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 H2 Table 28 Top Vent Three 90 Elbows H Maximum V Minimum feet meters feet meters 5 1 524 Elbow only 5 1 524 1 0 305 10 3 048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 H H1 25 ft 7 62 m maximum V V1 H H1 60 ft 18 288 m maximum Install th...

Страница 35: ...le vent then push it back out of the way b Apply a bead of Mill Pac Black 700 F high temperature sealant P N 10K81 to the inner adaptor collar approximately 1 2 from the end c Pull and extend the inner flexible vent d Slide the inner flex vent over the adaptor collar at least 1 3 4 NOTE Ensure the flex vent is free from damage or tears e Slide the gear clamp down and tighten it fully to secure the...

Страница 36: ... Flex vent to Secure Flex terminations only Do NOT substitute Secure Vent terminations or Secure Vent adaptor for Secure Flex components Secure Flex termination and adaptor collars are a different circumference than Secure Vent collars Secure Flex vent has an longer center tube to improve ease of installation 10 Complete the Field Wiring CAUTION The ground supply lead must be connected to the wire...

Страница 37: ...R HOT NEUTRAL OPTIONAL GROUND BATTERY HOLDER DFC WIRE HARNESS SPARK WIRE CABLE PILOT GROUND WIRE PILOT SENSOR CABLE HOOD IGNITER ROD FLAME SENSOR PILOT TUBE CPI SWITCH OFF O INTERMITTENT PILOT MODE ON STANDING PILOT MODE PROFLAME DFC BOARD PROFLAME VALVE ELECTRONIC PILOT ASSEMBLY B BLACK BR BROWN GY GRAY PU PURPLE R RED BL BLUE G GREEN O ORANGE W WHITE Y YELLOW WIRING COLOR CODE B B B R R W W B B ...

Страница 38: ...fireplace junction box 2 Remove the electrical inlet cover plate from the side of the unit by removing the plate s securing screws Table 13 3 If unit is not supplied with a strain relief remove the cover plate knockout Then feed the power supply wire through the knockout opening and into the unit junction box 4 Connect the black power supply wire to the lower outlet s red pigtail lead Figure 33 Co...

Страница 39: ...ording to the installation instructions provided with the kit NOTE The tab connecting the receptacles of the outlet box must be broken in FBK 100 and FBK 200 blower kit applications Figure 33 12 Connect the Gas Line All codes require a shutoff valve mounted in the supply line Figure 35 illustrates two methods for connecting the gas supply The flex line method is acceptable in the U S however Canad...

Страница 40: ...ame to check for leaks Turn on gas supply and test for gas leaks using a gas leak test solution also known as bubble leak solution NOTE Using a soapy water solution is an effective leak test solution but it is not recommended because the soap residue that is left on the pipes fittings can result in corrosion over time 1 Light the fireplace refer to the lighting instructions label in the control co...

Страница 41: ... sooting resulting from improperly setting the air shutter is not covered under the warranty The air shutter rod and nearby appliance surfaces are hot Exercise caution to avoid injury while adjusting flame appearance Flame Appearance and Sooting The flame should be blue at the base and yellow orange in the body of the flame When the fireplace is first lit the entire flame may be blue and will grad...

Страница 42: ...shutter is open too far Flame will be blue Air shutter gap should be decreased Figure 38 Air Shutter Adjustment Rod Air Shutter Adjustment Rod Down Fully Open Position Burner Tube Adjustment Rod Up Fully Closed Position Adjustment Set Screw 1 Move the adjustment rod down to decrease air flow and up to increase it The rod is located in the lower control compartment Position the air shutter to the f...

Страница 43: ...odels must have a barrier installed prior to operation 1 Open the control compartment door Page 50 2 Hold the barrier in front of the glass door and slide it up into the slots above the glass door and under the hood 3 Slide the barrier bottom down into the slots below the glass door securing it in place 21 Install the Finishing Materials 1 Complete finished interior wall NOTE To install the firepl...

Страница 44: ...ollez l étiquette sur la surface de la plaque de l interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 2 Si une télécommande est utilisée pour contrôler le foyer nettoyez la soigneusement pour éliminer la poussière et les traces de graisse...

Страница 45: ...V4 5L36 36 914 mm 77L74 SV4 5L48 48 1219 mm 77L75 SV4 5LA Telescopic Length Slip Section 2 to 7 1 2 rigid Catalog Number Model Description The following flashing comes packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 pack H6183 SV4 5HF5 Firestop Spacer 5 rigid H6...

Страница 46: ...rmination for flex with 12 305 mm of compressed flex vent see 750204M 94L05 SFKIT18SS Small Square Termination for flex with 18 457 mm of compressed flex vent see 750204M 94L06 SFKIT24SS Small Square Termination for flex with 24 610 mm of compressed flex vent see 750204M 94L07 SFKIT36SS Small Square Termination for flex with 36 914 mm of compressed flex vent see 750204M 94L08 SFKIT48SS SmallSquare...

Страница 47: ...nctionnement de l appareil converti n a pas été vérifié selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifié ayant réalisé l installation assume les responsabilités liées à la conversion In Canada The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirement...

Страница 48: ...on monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition...

Страница 49: ...terruptor opera la chimenea encendiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien...

Страница 50: ...f the lubricants used in the manufacturing process Depending on usage the burn in period may take a few hours or a few days NOTE Ventilate the site during the burn in period The resulting odor and haze may set off a smoke detector Do not operate the blower during the burn in period A white film may develop on the glass front during the first few fires as part of the burn in period The glass should...

Страница 51: ...electronic gas valve have a continuous pilot ignition CPI switch installed in the control compartment This switch allows the pilot to be switched from intermittent mode to continuous mode Intermittent Mode The pilot is extinguished when the fireplace is OFF Continuous Mode The pilot stays ON when the fireplace is OFF In periods of extreme cold condensation may form on the glass door when the firep...

Страница 52: ...o these instructions improper combustion could occur This could result in the excessive production of soot and or the colorless odorless toxic gas carbon monoxide CO NOTE If applicable install the firebox liner before placing the stone Logs can be installed after the volcanic stone Installing the volcanic stone and glowing embers 1 If necessary remove the glass door Page 55 2 Spread the decorative...

Страница 53: ...rackets Figure 48 Placing log 1 and 2 3 Align the notches in the bottom of the rear log 1 with the left rear brackets Figures 47 and 48 4 Position the left rear log 1 on the left rear bracket and the left front log 2 on the left front log bracket and the left burner locating tab Figure 47 Figure 49 Placing log 3 Figure 50 Placing log 4 and 5 5 Position the right front log 3 on the right front log ...

Страница 54: ...rs over burner slots Right Rear Log Bracket 1 Volcanic Stone Log Rack 3 2 3 Position rear log 1 on the left rear log bracket Figure 51 4 Position the left front log 2 and the right front log 3 against the log rack Figure 52 5 Position the left cross log 4 over the rear log 1 and left front log 2 with the front resting on the log rack Figure 53 Figure 53 Placing log 4 Figure 54 Placing log 5 4 2 1 ...

Страница 55: ...ed AVERTISSEMENT Une barrière conçue pour réduire le risque de brûlure par le hublot chaude est fournie avec l appareil et doit être installé WARNING The door should easily close without needing to be pressed down If it has to be pressed down to close the gasket in the top of the door should be dressed so it lays on the glass WARNING Do not operate appliance with the glass front removed cracked or...

Страница 56: ...hannel with the flat side toward the fireplace then swinging the base of the barrier into the brackets and lowering it into place 5 Close the control compartment door Removing the BARRIER 1 Open the access door 2 Lift the barrier to clear the brackets and swing bottom of barrier out 3 Lower the barrier to clear the top channel Removing the glass door 1 Open the control compartment door Page 50 NOT...

Страница 57: ...ponents However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the burn season inspect the horizontal termination for debris such as bird nests leaves paper or branches Remove any items from the surfaces of the termination prior to use Also be aware of shrubs and plantin...

Страница 58: ... at your local IHP dealer Never attempt to paint a hot fireplace Do not attempt to repaint the fireplace until the finish is completely cured Burn in Period on Page 50 If the surface becomes stained or marred it may be lightly sanded and touched up Logs Removing and cleaning the logs CAUTION The fiber logs become very fragile after curing Carefully remove the logs Clean carbon from the logs using ...

Страница 59: ... Page 70 Cleaning the burner Carefully remove the logs media Vacuum out any foreign matter on the burner e g lint carbon etc Ensure the burner ports are free of debris NOTE Improper positioning of logs media can create carbon build up and will alter the performance of the fireplace Inspecting the wiring Refer to the wiring diagram Figure 32 CAUTION When servicing controls label all wires prior to ...

Страница 60: ...of dislocation of the vent components Fireplace Inspection Qualified Service Technician Perform the appropriate fireplace inspection procedure detailed in this manual Replacing Glowing Embers Homeowner Qualified Services Technician Remove the old glowing embers and vacuum the area Place new glowing embers Figure 49 Replacing Batteries Homeowner Qualified Services Technician For electronic gas valv...

Страница 61: ...e speed 80L85 FBK 200 Blower Variable Speed with wall mounted switch 80L86 FBK 250 Blower Variable Speed with thermal snap switch Glowing Embers and Volcanic Stone Table 44 Glowing Embers and Volcanic Stone Catalog Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone Glass Media Table 45 Glass Media Brickaded Firebox Liner Kits Table 46 Brickaded Firebox Liner Kits Ca...

Страница 62: ... TOUCH WS S STAT Wall control Catalog Number Large LCD display Shows room and set temperatures in F and C Wall mounted Thermostatic or manual ON OFF operation Connects to wall switch wire H8864 Model WS S TSTAT ON OFF and Timer Control Kits Feature a timed ON OFF mode as well as manual ON OFF operation Table 48 ON OFF and Timer Control Kits Cost Effective Solution Catalog Number Manual ON OFF oper...

Страница 63: ...talog Model 85L87 FWSK Table 50 OFF ON Wall Switch Kit Variable Speed Wall Switch Kit The variable speed wall switch kit provides variable speed control if the optional FBK 100 blower kit is installed Table 51 Variable Speed Wall Switch Kit Catalog Model 045571H VSWS ACCESSORY COMPONENTS continued Termination Guard Kits The vent termination guards may be used to minimize exposure to the hot surfac...

Страница 64: ... released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob counterclockwise to ON 11 Close control compartment 12 If applicable Turn on all electrical power to the appliance ...

Страница 65: ...rnisseur de gaz Si la veilleuse ne reste pas allumée après plusieurs tentatives réglez la manette d admission du gaz à la position OFF et appelez un technicien qualifié ou le fournisseur de gaz 10 Tournez le bouton de réglage du gaz en sens inverse des aiguilles d une montre jusqu à sa position de marche ON 11 Fermer le compartiment de contrôle 12 Si applicable Mettez l appareil sous tension 13 Si...

Страница 66: ... which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a battery backup remove batteries if installed 4 Close the main line gas shut off valve 1 STOP Read the safety information above on this label 2 Read the Care and Operation manual including the section on Remot...

Страница 67: ...une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du récepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OFF pour sélectionner ON 10 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 11 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l admissi...

Страница 68: ...ghting instructions a Defective pilot generator thermocouple Check pilot flame it must impinge on thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that the connection between the valve and thermocouple are tight and secure 3 Pilot burning no gas to burner Valve knob ON and the standard burner OFF ON switch is ON NOTE If an optional remote switch is used f...

Страница 69: ... supply and gas shutoff valves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if necessary c Pilot flame is not engulfing the sensor Call a service technician d Obstructed vent system Call a service technician 4 Soot is present on the logs and glass a Excessive flame impingement on the logs Properly position the logs...

Страница 70: ...17 1 69L17 1 Millivolt Pilot Assembly Liquid Propane 69L18 1 69L18 1 69L18 1 69L18 1 Millivolt Piezo Igniter 10K86 1 10K86 1 10K86 1 10K86 1 Millivolt Piezo Igniter Wire 56L21 1 56L21 1 56L21 1 56L21 1 Millivolt Pilot Generator 60J79 1 60J79 1 60J79 1 60J79 1 Millivolt Thermocouple 74L57 1 74L57 1 74L57 1 74L57 1 Millivolt Pilot Tube 74L56 1 74L56 1 74L56 1 74L56 1 Millivolt Electrode and Cable H6...

Страница 71: ...1840 1 F1903 1 1 Glass Door F1905 1 F1841 1 F1842 1 F1906 1 8 Control Compartment Door F1898 1 F1835 1 F1836 1 F1899 1 Touch Up Paint exterior F1882 1 F1882 1 F1882 1 F1882 1 Touch Up Paint interior F1881 1 F1881 1 F1881 1 F1881 1 Glowing Embers 88L53 1 88L53 1 88L53 1 88L53 1 Volcanic Stone 80L42 1 80L42 1 80L42 1 80L42 1 WARNING Never use substitute materials Use of non approved parts can result...

Страница 72: ...Back view not representative of all fireplace models 6 3 2 8 4 1 7 5 Figure 56 Replacement Parts WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury ...

Страница 73: ...________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 74: ...________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 75: ...ot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive te...

Страница 76: ...ke changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 900004 01 Rev J 03 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 P900004 01 Innovative Hearth Products Aries Direct Vent Gas Fireplaces Installatio...

Отзывы: