INSTALLATION
Continued
Figure 15 - Attaching Fireplace to Wall Studs
Nailing Flange
Nails or
Wood
Screws
Figure 16 - Minimum Mantel Clearances for
Built-In Installation
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12" 16" 20"
1
1
/
2
"
6
3
/
4
"
12"
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
Figure 14 - Rough Opening for Installing in
Corner
*14
1
/
2
"
50
3
/
8
"
71
1
/
4
"
35
5
/
8
"
*14
1
/
2
"
41
1
/
2
"
0" CLEARANCE
FOR 36" MODELS
Figure a
Figure b
* THESE DIMENSIONS ALLOW FOR MINIMUM CLEARANCES TO
A 45° PROJECTED SIDE WALL
HOWEVER, CLEARANCES TO PROJECTED MANTEL TRIMS AND
FACINGS ARE ALLOWED WITHIN A MINIMUM OF 16" TO A
PERPENDICULAR WALL AS SHOWN IN
FIGURE 8, ON PAGE 11
* THESE DIMENSIONS ALLOW FOR
ANCES TO A 45°
OJECTED MANTEL TRIMS AND
ACINGS ARE ALLOWED WITHIN
RE 5, ON PAGE 10
55
5
/
8
"
39
3
/
8
"
34
1
/
2
"
27
3
/
4
"
0" CLEARANCE
*10
1
/
2
"
*10
1
/
2
"
FOR 32" MODELS
WARNING: Do not allow any com-
bustible materials to overlap the fi rebox
front facing.
WARNING: Do not allow noncombus-
tible materials to cover any necessary
openings like louvered slots.
WARNING: Use only noncombustible
mortar or adhesives when overlapping
the front facing with noncombustible
facing material.
IMPORTANT:
When fi nishing your fi rebox, com-
bustible materials such as wall board, gypsum
board, sheet rock, drywall, plywood, etc. may be
butted up next to the sides and top of the fi rebox.
Combustible materials should never overlap the
fi rebox front facing.
IMPORTANT:
Noncombustible materials such as
brick, tile, etc. may overlap the front facing, but
should never cover any necessary openings like
louvered slots or screen assembly.
7. Check all gas connections for leaks. See
Check-
ing Gas Connections
,
Page 16
.
8. Plug electrical cord into electrical outlet.
9. Install trim after fi nal fi nishing and/or painting
of wall
(see
Figure 7, Page 10
).
Minimum clearance requirements include any
projections such as shelves, window sills, fi replace