![Astralpool VICTORIA DUAL SPEED Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/astralpool/victoria-dual-speed/victoria-dual-speed_manual_2990668009.webp)
Victoria Dual Speed
- ASTRALPOOL
9
The estimated working life of the parts above has been established according to normal product use and installation
conditions.
Follow the instructions in the installation manual to maintain the working life of the pump.
6. REMOVAL
- The motor unit can be removed from the pump body without having to disconnect the pump's suction and return
pipes.
- To remove the Motor unit from the pump body, remove the screws joining them together.
7. TROUBLESHOOTING
1. The pump is not primed
4. The pump will not start
2. The pump releases only a small flow of water
5. The motor is making a noise but will not start
3. The pump makes a noise
6. The motor is stopped
1 2 3 4 5 6
CAUSES
SOLUTIONS
Air entering the suction pipe
Check the condition of connections and seals
on the suction pipe
Filter cap badly sealed
Clean the filter cap and check the condition of the
rubber seal
Inverted motor turning
Invert 2 power phases
Wrong voltage
Check the voltage on the characteristics plate and
that of the mains
Pre-filter blocked
Clean the filter
Load loss in the installation
Prevent parts from causing load loss wherever
possible
Pump incorrectly secured
Secure the pump correctly
Motor blocked
Remove the motor and contact the technical service
Increased temperature in the
terminal box due to electric
arc
Check the terminal box connections
The thermal protection trips
Connect the cables correctly to the terminal boxes
Incorrect terminal box
connections
Tighten the cable correctly to the terminal / Adapt
the size of the cable connection to the terminal box
ENGLISH
Содержание VICTORIA DUAL SPEED
Страница 47: ...47...