Concept
Code
Parameter name
Range
Factory
setting
Unit
Observations
Temperature
F11
Temperature setting point
F14 – F13
28
°
C
F12
Temperature difference
1 – 10
1
°
C
F13
Max setting temperature
30 – 100
40
°
C
F14
Min setting temperature
1 – 29
10
°
C
F15
Auto mode temperature
difference
0 – 20
1
°
C
F17
ID
1 – 255
8
-
F19
Password (Installer)
0 – 999
-
-
0: Without password (Consult your
salesman)
F20
Password (Manufacturer)
0 – 999
-
-
0: Without password (Consult your
salesman)
Compressor
F21
Compressor delay time
1 – 10
5
min
F22
Compressor Phase protection
0 – 1
1
0: no protection
1
:
have protection
F24
Number of circuits*
1-2
Depends on
the model
of the
machine
2
1
:
1 Compressor
2
:
2 Compressors
F25
Water fiow switch delay time
0-100
1
min
F26
Low limit temperature
-20 - 10
0
Not enabled select -20
F27
The lower limit temperature of
Low speed operation
-10~30
-10
°
C
1. Temperature differential ±1°C.
2. Always working at low speed (-
10ºC).
F28
The upper limit temperature of
Low speed operation
35~100
44
°
C
Temperature differential ±1°C
F29
OPERATING MODES ENABLED
0 / 1 / 2 / 3
1
0: Automatic mode (C/H)
1: Heat mode (Heat)
2: Cool mode(Cool)
3: Choose the mode (M)
Defrost
F31
Defrost start temperature
-10 – 0
-3
°
C
F32
Defrost end temperature
5 – 35
15
°
C
F33
Defrost start time
1– 120
1
min
F34
Max defrost time
3 – 20
10
min
F35
Pipe1(2) fault
,
Defrost start
temperature
-10 - 20
7
°
C
Ambient Temp.
Defrost according to F33/34.
F36
Alarm Delay Time after Defrost
0 – 120
3
min
F37
4-way valve mode
0 - 1
0
1: heating 4-way valve has electricity
0: heating 4-way valve has not
electricity
Remote
control
F38
Remote Cooling MODE
0 – 1
0
0: Always cooling, and the set point is
not taken into account
1
The set point is taken into account
F39
Remote Heating MODE
0 – 1
0
0: Always heating, and the set point is
not taken into account..
1
:
The set point is taken into
account
Voltage
consumption
F40
Maximum consumption
protection
2-40
Depends on
the model
of the
machine
10
0
:
not enable
PROHEAT II-35 = 18A
PROHEAT II-45 = 23A
PROHEAT II-60 = 32A
PROHEAT II-90 = 23A
PROHEAT II-120 = 32A
F42
Alarm delay time due to excessive
consumption
0 – 30
3
S
F44
Percentage phase curremt
unbalance
5 – 50
20
%
F45
Alarm delay time phase curremt
unbalance
0 – 60
3
S