SELECTION OF APPROPRIATE SPEEDS 

General Rules: 
 

 

The total volume of water in your pool should be turned over at least once a day. 

 

If operating for longer periods of time, you may be able to turn the output of your salt chlorinator to a lower level.  Check 
your chlorine level frequently to ensure you do not over or under chlorinate your swimming pool. 

 

Low Speed is the recommended setting for your daily filtration flow rate – enough to gentle turn the water over once per 
day and circulate the water completely around your pool. 

 

High Speed is generally set up to backwash your sand filter.   As a rule of thumb, this speed should be set so that the 
gauge on your filter is approximately 70kPa to 100 kPa in pressure but this will depend on the size of your filter, and the 
size and length of the backwash pipe line. Other purpose flow rates may include but are not limited to:  operating spa jets, 
operating water falls or water features, operating a suction pool cleaner. 
 

 
In warmer weather, or when the pool is used a lot, your pump should operate for 12 hours a day or more.   Check your chlorine 
levels and visually inspect your water to ensure that (a) you have adequate chlorine and (b) the water in your pool looks clear 
and inviting.  If you have any doubts, take a sample of water to your local pool shop for a water analysis. 
 
Examples of Speed Selection during operation and use of your eCombi EE2 Pump: 
 

Function 

Speed 

Vacuuming Pool or Spa 

High Speed 

Operating Spa Jets 

High Speed 

 

Low Speed or High Speed, depending on effect required 

Cleaning up pool with Cloudy Water 

Up to 24 hours on High Speed 

General Filtration 

Low Speed (8 hours in winter, 8 to 12 hours in summer) 

 

 

 
Some Tips: 
 
The eCombi EE2 will provide around 29,000 litres per hour on high speed, depending on pipework, valves, filter size and other 
equipment installed on your pool.   On low speed the flow rate is approximately 14,000 litres per hour, therefore, operating 
the pump 4 hours per day will provide a 56,000 litre pool one complete turn over.   Low speed will use approximately 20% of 
the power consumption
 that high speed will use. 
 
As a guide, low speed should achieve a visible skimming of the surface of the pool through your skimmer box.  When connected 
to an AstralPool compatible salt chlorinator, Viron Connect Touch Screen Control System, we recommend that for one hour a 
day the filtration period is operated on at HIGH medium speed to achieve full circulation and good surface skimming of the 
pool.  The balance of the filtration cycle can then be set on low speed. 
 
However, should your pool water develop cloudiness or your pool surface exhibit algae growth you may need to increase the 
time on high speed to ensure adequate circulation of water and chlorine to all parts of your Pool. 
 
It is important to check your chlorine levels, pH and other parameters to ensure your water quality is correct before adjusting 
the speed of your pump.  We recommend these checks are carried out by your professional pool shop or service technician. 
  

 

 

Содержание eCombi EE2

Страница 1: ...ERATING INSTRUCTIONS www astralpool com au sales astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS eCombi EE2...

Страница 2: ...THEY DO NOT PLAY WITH THE APPLIANCE PUMP PRODUCES HIGH PRESSURES STAND CLEAR OF PUMP AND ALL FILTRATION EQUIPMENT DURING START UP PUMP MUST ONLY BE INSTALLED BY A QUALIFIED POOL INDUSTRY PROFESSIONAL...

Страница 3: ...ed by a pool professional trained by Astral Pool to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FE...

Страница 4: ...e to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum height of suction for lift of water from pool surface to pump...

Страница 5: ...the skimmer or filtration for the pool Low is the recommended setting for everyday filtration of your pool when a cleaner is not connected 5 The eCombi EE2 will automatically start on High for the fir...

Страница 6: ...ur eCombi EE2 Pump Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Low Speed or High Speed depending on effect required Cleaning up pool with Cloudy Water Up to 24 hours...

Страница 7: ...allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of your Ecombi EE2 Pump 4 When clea...

Страница 8: ...basket Empty leaves and debris Three Monthly Check Lid O ring and inlet outlet O rings for leaks Isolate Pump turn power off clean and grease O rings or replace if necessary Three Monthly Check surro...

Отзывы: