Astralpool eCombi EE2 Скачать руководство пользователя страница 5

INST 347 eCombi EE2 Pool & Spa Pump V08.20 
 

E.

 

For pump installations 500mm above water level, it generally requires a foot valve at the pool or check valve in the 
suction line.  Suction lines must be installed below water level until just in front of pump location and vertical riser 
used to reach pump inlet.  AstralPool pumps are rated to a maximum head of 25 metres however refer to your pumps 
data plate for actual achievable pressure. 

 

F.

 

All pumps will operate quieter and perform more efficiently if a straight length of 450mm pipe is plumbed horizontally 
into the front of the pump. 

 

G.

 

Water temperature not to exceed 35C degrees. 

 

H.

 

Pumps must be either 

 

a.

 

Supplied by an isolated transformer, or 

b.

 

Supplied  through  a  residual  current  device  (RCD)  with  a  rated  residual  operating  current  not  exceeding 
30mA. 

OPERATION 

 
1.

 

Switch on power to pump, motor to start. 

 
2.

 

If some flow of water does not establish within on half minute, switch off and prime pump again.  If pump does not prime 
within 3 attempts, check all suction connections for sealing.  If these are satisfactory, a check or foot valve is required to 
hold water for prime. 

 
3.

 

If the water flow through pump is always tedious to obtain at start-up after cleaning the lint basket, then an examination 
of the system to establish a reason and correct the cause is recommended. Eg. Check valve, air leaks, faulty seal, cracked 
lint pot lid, etc. 

 
4.

 

The eCombi EE2 has 2 set speed settings – Low and High. High should be used when backwashing, manually vacuuming 
the pool or operating spa jets or some water features such as waterfalls.   Low speed can be used for gentle spa jet action, 
when suction cleaner is connected to the skimmer or filtration for the pool.   Low is the recommended setting for everyday 
filtration of your pool when a cleaner is not connected. 

 
5.

 

The eCombi EE2 will automatically start on High for the first 5 minutes to assist in priming and substantially fill the hair 
and lint pot with water.    After 5 minutes the pump will revert to the last speed it was set at before it was turned off. 

 
6.

 

During normal operation, it is recommended that the pump be operated on Low for 12 hours per day. This will achieve 
the lowest operating costs with the lowest noise level.   Should your pool have areas where water is not turning over 
when pump is on Low, increase the speed setting. 

 
Notes: The appliance is not intended for use by person including young children or infirm persons with reduced    physical, 
sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety. 
Please ensure that young children are supervised to ensure that they do not play with the pump. 
  
To avoid a safety hazard, the supply cord if damaged, must only be replaced by Astral Pool, or its service agent or a suitably 
qualified person. 
 
The eCombi EE2 pump is designed to operate in ambient temperatures of 2°C to 40°C. 
 
Hours of Operation 
 
On  low  speed  your  eCombi  EE2  pump  makes  very  little  noise  and  is  unlikely  to  be  intrusive  to  you  or  your  neighbours.  
Generally,  your  pool  filter  pump  should  operate  for  a  minimum  of  8  hours  a  day  to  provide  sufficient  skimming  (thereby 
reducing the amount of debris that falls to the bottom of the pool) and to allow the chlorinator to provide sufficient chlorine 
to sanitise your pool. 
 
Greater energy savings occur when operating the pump for longer periods at the low speed instead of operating for shorter 
periods at the high speed.

 

 

Содержание eCombi EE2

Страница 1: ...ERATING INSTRUCTIONS www astralpool com au sales astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS eCombi EE2...

Страница 2: ...THEY DO NOT PLAY WITH THE APPLIANCE PUMP PRODUCES HIGH PRESSURES STAND CLEAR OF PUMP AND ALL FILTRATION EQUIPMENT DURING START UP PUMP MUST ONLY BE INSTALLED BY A QUALIFIED POOL INDUSTRY PROFESSIONAL...

Страница 3: ...ed by a pool professional trained by Astral Pool to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FE...

Страница 4: ...e to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum height of suction for lift of water from pool surface to pump...

Страница 5: ...the skimmer or filtration for the pool Low is the recommended setting for everyday filtration of your pool when a cleaner is not connected 5 The eCombi EE2 will automatically start on High for the fir...

Страница 6: ...ur eCombi EE2 Pump Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Low Speed or High Speed depending on effect required Cleaning up pool with Cloudy Water Up to 24 hours...

Страница 7: ...allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of your Ecombi EE2 Pump 4 When clea...

Страница 8: ...basket Empty leaves and debris Three Monthly Check Lid O ring and inlet outlet O rings for leaks Isolate Pump turn power off clean and grease O rings or replace if necessary Three Monthly Check surro...