Astralpool eCombi EE2 Скачать руководство пользователя страница 4

INST 347 eCombi EE2 Pool & Spa Pump V08.20 
 

DIMENSIONS 

 

 

INSTALLATION

 

 

This appliance must be installed by a trained pool professional service technician.  When installing the appliance, ensure all 
parts are installed in the correct zone in accordance with the wiring rules.  In particular refer to AS/NZS 3000 (Australia) and 
EN 60364 (EU). 

A.

 

Plan position of pump so that it will be:

 

 

1.

 

Free of water flooding, such as in a sump, garden hollow, ditch or at bottom of bank with run off. 

2.

 

On a stable base so that: 

 

a)

 

The pump is not left suspended by its fittings, causing a leak or failure with loss of water. 

b)

 

Movement through vibration is restricted. 

c)

 

No strain is put on attaching pipe or other expensive equipment. 

 

3.

 

Accessible for maintenance and easily removed for service. 

4.

 

Breathing space.  Pump should not be crowded which will prevent cooling airflow from fan.  Overheating due to 
lack of cooling voids warranty. 

5.

 

Within reach of power point without extension/plugs liable to corrosion, shorting, etc. 

6.

 

At a minimum height of suction for lift of water from pool surface to pump inlet. 

 
B.

 

For best pump performance keep suction pipe length as short as possible with minimum number of bends and use 
50mm high pressure PVC suction and return pipe.  All equipment such as filters, heaters, chlorinators must have a 
minimum of 50mm connections. 

 
C.

 

Secure the barrel unions supplied into the attaching pipe work, using approved priming fluid and solvent cement as 
normal practice, coating both surfaces.   NOTE:  Always wear protective gloves when handling and using glue and 
priming fluid.  Ensure no excess adhesive runs into the union proper affecting the sealing or removal abilities.  Allow 
24 hours to dry before starting pump.  DO NOT USE “GREEN” glue on barrel unions.  This can cause damage to the 
ABS material used to manufacture the unions. 

 

D.

 

Install isolation valves before the pump section and after equipment, if the pump is below the water level of the pool. 

 

Содержание eCombi EE2

Страница 1: ...ERATING INSTRUCTIONS www astralpool com au sales astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS eCombi EE2...

Страница 2: ...THEY DO NOT PLAY WITH THE APPLIANCE PUMP PRODUCES HIGH PRESSURES STAND CLEAR OF PUMP AND ALL FILTRATION EQUIPMENT DURING START UP PUMP MUST ONLY BE INSTALLED BY A QUALIFIED POOL INDUSTRY PROFESSIONAL...

Страница 3: ...ed by a pool professional trained by Astral Pool to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FE...

Страница 4: ...e to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum height of suction for lift of water from pool surface to pump...

Страница 5: ...the skimmer or filtration for the pool Low is the recommended setting for everyday filtration of your pool when a cleaner is not connected 5 The eCombi EE2 will automatically start on High for the fir...

Страница 6: ...ur eCombi EE2 Pump Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Low Speed or High Speed depending on effect required Cleaning up pool with Cloudy Water Up to 24 hours...

Страница 7: ...allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of your Ecombi EE2 Pump 4 When clea...

Страница 8: ...basket Empty leaves and debris Three Monthly Check Lid O ring and inlet outlet O rings for leaks Isolate Pump turn power off clean and grease O rings or replace if necessary Three Monthly Check surro...