ON / TIMER:
x
If the spotlight is off, it is switched on in the last operation mode used and the TIMER function is activated, switching it off
automatically after a time pre-set from the remote control. (duration changes of the timer must be performed from the remote
control).
x
If the spotlight is in SET COLOUR or SEQUENCE mode, the TIMER function is activated.
NOTE: The Remote Control must remain off when the Receiver-Modulator pushbuttons are being used.
LED indicator:
By observing the green led of the Receiver-Modulator, you can determine the spotlight operation status:
x
Led off:
Power supply is disconnected.
x
Flashing every 2 sec.
Spotlights with leds off.
x
Led on without flashing:
Spotlight in SET COLOUR or SEQUENCE mode.
x
Slow flashing:
TIMER function on.
x
Quick flashing:
INSTRUCTION function
x
Flashing for 2 sec.
Receiving order from the remote control.
6.2.4 Remote control (code 27817)
Technical specifications:
Operation frequency:
433 MHz
Scope in the open:
50 m.
Battery:
9 Vdc type 6LR61.
Description of the keypad:
ON / OFF key:
If the remote control is off, this key switches it on sending the last order run. If it is on,
the remote control is turned off without switching off the spotlight. It will switch off if no button is
pressed for more than one minute.
COL (COLOUR) key:
This key activates the SET COLOUR mode. A colour can be selected from the
following table by pressing it successively:
The following will be displayed: C01, C02 .....C12 depending on the colour selected.
SEC (SEQUENCE) key:
This activates the SEQUENCE MODE and enables you to select one of the nine
different programmes available. Each programme is defined by a timer that determines the duration in
which a colour is on, and another timer to determine the blending and transition time to the next colour.
The following will be displayed: P-1, P-2 .......P-9, depending on the programme selected.
ACT (COLOUR ACTIVATOR) key:
This activates or deactivates the presence of the colours in the sequence. . A maximum of 12
colours can be used in the sequence, and if you do not want some of these colours to form part of the sequence, you can deactivate
them using this key.
When a colour is activated, it is shown in the display with an upper case C, and if it is deactivated it appears with a lower case c. For
example: C05 (activated) or c05 (disabled).
TIMER (AUTOMATIC OFF) key:
This key activates the automatic off timer. Each time you press the key, the display shows the time
before it is switched off (15, 30, 60, 90, 120 and 180 minutes). Once the automatic off function is activated, it can be deactivated
by switching off the spotlight with the OFF key.
When the TIMER is activated, the spotlight switches off for a second to indicate that the timer is activated.
It is used to switch off the spotlight. At the same time, the remote control will switch off.
NOTE: The instructions of the remote control prevail over instructions of the Modulator-Receiver.
7. SAFETY WARNINGS:
x
The persons who are In charge of assembly shouid have the required qualificatlons for this type of work.
x
Avoid making contact with the electric voltage.
x
Comply with the currení standards regarding accident preventlon.
x
In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMINGPOOLS.
x
Any operation related to the maintenance or replacemení of parts shouid be performed with the floodlamp disconnected from the
electric power system.
x
Do not handie wlth wet feet.
6
Содержание 27820