8
S I G N A T U R E
After making the electrical connection, operate as follows for the first commissioning:
• Provide power to the ensemble by activating the 230 Vac. at the Modulator inlet and it will
automatically synchronize with the transformer. The greed LED on the Modulator will blink
every 2 sec. and the lamp will remain off.
• Setting up the Remote Control
- Hold down the OFF key on the Modulator, the green LED will flash quickly indicating that
it is in the Learning mode.
- Turn on the Remote Control and press any key. If you have several Remote Controls,
repeat the operation so that the Modulator registers all of them (maximum of eight).
MODuLATOR (Code 27818)
Install the Modulator, protecting it from corrosive
environments, outside of metal boxes and far from metal
pipes.
OPERATION
Turning the projectors on
The projectors will turn on when you press any key. If
you press the key, the projectors turn on in the same
state they were in before being turned off: fixed colour or
a sequence of certain colours and times.
If you press the COLOR key, the projectors turn on with
the last fixed colour that was used.
If you press SEQuENCE or SPEED, they turn on with the last sequence used.
Turning the projectors off
By hitting the key, you can shut the projectors off. The state (colour or sequence) of the lamps
will be saved in the memory so that when they are turned on again, they will be in the same
colour or sequence they were in before being shut off.
A long stroke of the key on the Modulator (regardless of whether the projector is on or off)
puts the receiver in the “Link” state which allows you to register the Remote Control with a single
stroke of any key on the Remote.
To select the colour
The COLOR key allows you to select 1 colour out of the 12 featured in the system. With each
stroke, you can change the colour. When you get to the last colour and hit the key, you go
back to the first.