13 Ref.: Ozone generator-AstralPool-gb-R11
From this point the ozonated air exits the chamber through an automatic bleeder valve that allows only the air to flow
through, but not the water
(see Figure 11)
. This purged air then flows to the ozone destructor where it is eliminated by the
catalytic effect of the activated charcoal in the destructor.
The off-gassing chamber is equipped with a level tube for constant visualization of proper operation. The level tube is
made of plastic (PVC glass) with a diameter of 20 mm and has three levels. The first level is the
OK level
, which is the
optimal operating level. The second level is the
maintenance level
, which is the minimal working level of the equipment
for the water in the chamber when it is running continuously. Lastly, the third level is the
alert limit
. When this level is
reached, the bleeder valve and other fittings should be checked, as this level warns the user that the system is not
working properly.
FIG. 11
Off-gassing chamber
Ozone destructor
LEVEL PIPE
PVC-GLASS
D20 mm
Pipe PVC-GLASS
D 32 mm
OFF-GASSING
CHAMBER