12 Ref.: Ozone generator-AstralPool-gb-R11
This board must be located in a dry, well-ventilated area that is protected from the weather in the machine room.
A breaker switch must be added to this board for the pressure pump (
Ozone Generators Spas/ Triox R-1:
70/5 (07946);
Ozone Generator Triox R-2/Ozone Generator Triox R-3:
70/7 (07947):
Ozone Generator Triox R-4
120/7 (07948)), as
well as the ozone generator and a safety contactor for this pump.
The electric operation must allow the various components to work as follows:
1
The existing water treatment pump will be running.
2
The pressure pump will run (
Ozone Generator Triox Spas/ Triox R-1
: 70/5 (07946);
Ozone Generator Triox R-2
/Ozone Generator Triox R-3
: 70/7 (07947);
Ozone Generator Triox R-4
: 120/7 (07948)), only if the treatment pump
is running.
3
The
OXSAN
ozone generator will run only if the treatment pump and the pressure pump are running (
Ozone
Generator-1
: CM 70/5 (07946);
Ozone Generator Triox R-2/Ozone Generator Triox R-3
: 70/7 (07947);
Ozone
Generator Triox R-4
: 120/7 (07948)). If only one of the pumps is working, the
Ozone Generator
cannot run.
6. EQUIPMENT WITH OFF-GASSING CHAMBER (OPTIONAL)
Operation of the off-gassing chamber
6.1 Manufacture
The chamber is constructed of a cylindrical fiberglass preform and two preforms for the bases. Inside, an inflatable mold
compresses the fiberglass while the vinyl ester resin is injected.
6.2. Chemical properties:
The chamber is highly resistant to corrosion and unaffected by water or most chemicals (including ozone).
The composition of the materials used (fiberglass plus vinyl ester resin) and the sealed design allow the tanks to resist
temperatures as high as 75ºC.
6.3. Mechanical properties:
The seamless manufacturing system provides excellent pressure resistance up to 10 kg/cm
2
, and to water hammer.
6.4. Operation:
This chamber has two main functions:
Eliminate large bubbles of ozonated air, a process known as off-gassing.
Increase air-water contact and mixing.
The ozonated water inlet is positioned at the top of the tank and consists of a 1” threaded inlet in the 4” PVC lid. The water
outlet is located at the bottom of the chamber. As it streams downward, the ozonated water gradually loses ozonated air,
which rises to the top of the chamber.