3. STORAGE
The machine is stored by the Manufacturer or the Distributor.
4. INSTALLATION
The machine must only be installed by the Technician.
When the machine is being installed, the Techni-
cian must replace the water in the hydraulic cir-
cuits.
The machine's support base must be perfectly flat,
not incline by more than 2° and have no irregulari-
ties.
The electrical system must be equipped with a
suitable residual-current device in compliance with
current laws and safety regulations.
5. COMMISSIONING
The machine must only be commissioned by the Technician.
6. OPERATION
6.1 Safety precautions
Carefully read the instructions provided in chapter
"I. SAFETY PRECAUTIONS" on page 33.
6.2 Emissions
Vibrations
Under conditions of use that meet the indications of correct
use provided in this manual, any detected vibrations do not
give rise to dangerous situations.
Sound emissions
The noise level emitted by the machine is on average lower
than 70 dB; therefore, the use of personal protective equip-
ment to prevent hearing damage is not compulsory.
Notify the Manufacturer if the machine emits unusual noises.
Electromagnetic environment
The machine is designed to work properly in any industrial
electromagnetic environment, falling within the Emission and
Immunity limits provided by current standards.
6.3 Turning the machine on and off
During the machine's heating-up phase (roughly
20 minutes), the negative pressure valve will re-
lease steam for a few seconds until the valve closes.
The temperature, instead of the pressure, will be shown on
the display in °C, until this reaches 100°C. Once this value has
been reached, the value will switch over to bar (pressure).
If the machine is inactive for longer than a week,
the Technician must replace 100% of the water in-
side the hydraulic circuits.
6.3.1
Start-up
After the hydraulic and electrical mains have been connected,
make sure that the drain tray (
5
) under the cup support grille
is correctly connected to the drain.
4
5
Check that all the steam valves are closed. Turn on the ma-
chine using the main switch (
4
) and follow the indications on
the machine’s display.
When the machine turns on, it performs a functional test and
reports information regarding the installed software:
•
XX.XX.XXXX: update date
• RY: revision number
FUNCTIONAL TEST
EVPRO XX/XX/XXXX RX
• OK indicates that the machine is working correctly. If there
is a negative result, check the warning on the display.
TEST
-OK-
•
When the machine is turned on, the motor pump is acti-
vated which starts to fill the steam heating unit and the
water heaters for the coffee (there are the same amount
of these as there are dispensing groups in the machine).
COFFEE
FILLING UP WATER
Содержание Plus4YouTS
Страница 215: ......