![Astoria 2GR Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/astoria/2gr/2gr_use-and-maintenance-manual_2990323027.webp)
27
of
92
TECHNICIANS manual
ENGLISH
5.6
Drilling the support base
If holes need to be drilled into
the support base to let the water
inlet hoses, outlet hoses and power
cables pass through, follow the
directions given in the drawings
below.
5.7
Hydraulic connection
5.7.1 Water supply
The appliance’s water supply
must provide water which is suit-
able for human consumption, and
must conform with the regulations
in force in the place of installation.
The owner / manager of the system
must confirm to the installer that
the water meets the requirements
above.
5.7.2 Materials to be used
When installing the appliance,
only the components and materials
supplied with the appliance are to be
used. Should the use of other com-
ponents be necessary, the installer
must verify if they are suitable for
coming into contact with water used
for human consumption.
5.7.3 Hydraulic connections
The installer must carry out the
hydraulic connections in accordance
with the hygiene norms and the
hydraulic safety norms for environ-
mental protection in force in the
place of installation.
1. Add a tap to the water supply in
order to stop water from flow-
ing to the machine;
2. In order to prevent damage, it
is advisable to install the water
purification filter where it will
be protected from accidental
blows;
3. To avoid oxidisation building up and damage to the machine over time, do not use iron connections for the
hydraulic system, even if they are galvanised.
STORM 4000 (3GR)
DRILLING POSITION FOR CONNECTION / DRAIN
1236 mm
817 mm
678 mm
=
=
360 mm
672 mm
139 mm
221 mm
Foro /
Hole
Ø100 mm
3 GROUPS
STORM 4000 (2GR)
DRILLING POSITION FOR CONNECTION / DRAIN
1096 mm
677 mm
539 mm
=
=
360 mm
672 mm
139 mm
221 mm
Foro /
Hole
Ø100 mm
2 GROUPS