Please Note: Due to the complexity of different building methods Astor 

Bannerman do not supply installation fixings and anchors.

 

Important: The attachment rail is the main load bearing fixing; it is vital that it is secured 

correctly .

Measure 100mm up from the floor along the centre-line of the final position of the unit; using a 

spirit level, draw a horizontal line at least 50mm long. 

Place the attachment rail with the open lip upwards, on the line. With a pencil mark two of the 

holes for the rail at least 50mm apart

Using a masonry bit, drill two 6mm full depth pilot holes at the marked positions and then open up 
in order to accept the Anchors.

Centre of fixing holes

1200mm above Floor

 

Fix the attachment rail, open lip 

uppermost to the wall using suitable 

fixings.

Ensure that the rail is level using a spirit 

level (adjust to suit) and check that it is 

secure.

With assistance, place the rise and fall unit 

onto the wall ensuring that the two short 

rails welded to the unit engage with the 

one on the wall. 

Ensure that the unit is level, then mark 

the wall through the remaining three 

attachment points, two on the lower 

horizontal beam and one on the upper 

horizontal beam 

Remove the unit from the wall and at the 

three marked positions drill three 6mm full-depth pilot holes.

Open the upper hole to accept a plastic wall plug. 

Fit supporting Anchors in the two lower holes

Place the rise and fall unit back onto the wall-mounted rail. Fully fix the rise and fall unit to the 

wall. 

Ensure that the mains supply to the junction box on the wall is switched OFF.

Electrically connect the rise and fall unit to fused outlet behind the unit with the three-core cable 

supplied.

Lower the arms and ensure the handset is fitted 

BEFORE

 switching the power on

Содержание ABW6SP

Страница 1: ...Warranty No Height Adjustable Basin ABW6SP OWNERS MANUAL INSTALLATION GUIDE ...

Страница 2: ... basin Press and hold button to lower basin Press and release button to turn Hot water on or off Press and release button to turn Cold water on or off Press and release button to raise or lower plug Press and release button to turn light on or off Following functions apply to the SP version only ...

Страница 3: ...must not be used i e drain cleaners acetone oven cleaners or acids The rise and fall unit mirror and handset should be cleaned using a warm soapy solution and rinsed with a damp cloth Attention should always be paid to instruction labels on the outside of cleaning agent containers Manual operation of the lever tap system In normal operation the levers should be facing forward towards the user when...

Страница 4: ... 0003 Holder handset 1 7 20 040 50 0006 Handset ABW6 grey 6 button 1 8 10 041 00 0021 Tube copper 70mm ABW6sp 2 9 10 041 00 0020 Tube copper 45mm ABW6sp 6 10 21 090 00 0390 Tie cable 12 300mm 1 11 20 041 90 0001 Hose kit 2pr 300x550mm 1 2 flat 15mm brass tube ABW6sp 1 12 10 041 30 0002 Plug actuator assembly 1 13 20 040 30 0008 Connector 15mm 1 2 in brass 303 SF 2 14 20 040 30 0009 Connector 15mm ...

Страница 5: ...equired with flush mounted a flex outlet cover on the wall behind the unit at a height of 1100mm from the floor on the centreline of the unit Fixing The basin assembly should be fixed to a load bearing wall i e strong enough to carry a 100kg load on wall fixing which is flat and free from obstruction from 200mm 2200mm above the floor If the basin needs to be fixed to a stud wall the wall will need specia...

Страница 6: ...e fixings Ensure that the rail is level using a spirit level adjust to suit and check that it is secure With assistance place the rise and fall unit onto the wall ensuring that the two short rails welded to the unit engage with the one on the wall Ensure that the unit is level then mark the wall through the remaining three attachment points two on the lower horizontal beam and one on the upper hor...

Страница 7: ...and place the up turned basin on the arms Fit the tap bodies to the basin as shown Ensure there is 35mm of threaded body showing above the basin deck to allow fitting the handle Ensure the nylon washer is fitted under the handle screw to remove any clearance on the spline Fit the 1 2 15mm tap adaptors Fit the spout in position and connect the flexible hoses as shown Fit the overflow hose and waste...

Страница 8: ...Page Version 2 11 04 2016 30mm 50MM HOT INLET COLD INLET SPOUT into BASIN Pipe connection diagram Sloenoid Sloenoid Tap body Tap body ...

Страница 9: ...he basin is under the white plastic upper cover which holds the mirror COLD SUPPLY HOT SUPPLY Hoses Rear view The mains water supply can now be fitted Ensure both the hot and cold mains water supplies have been flushed and only then fit the open ends of the supply hoses with the filter screens supplied onto the isolation valves Ensure the free end of the supply hoses are passed through the recess ...

Страница 10: ... to the rear of the trunking Pass the trunking behind the hot and cold supply hoses taking care to ensure that the self adhesive tape is kept away from the wall at this time The top of the trunking needs to be aligned with the recess in the bottom left hand side of the rise and fall unit through which were passed the supply hoses earlier Using a level ensure the trunking is vertical Once aligned p...

Страница 11: ...t as necessary and ensure that mains voltage is fully reconnected then press the reset button situated next to the handset connector If the light fails to illuminate further assistance will be required Fault The rise and fall unit travels upwards but not downwards Cause There is an obstruction underneath the basin or the microswitch is not engaged Remedy Depress the Up button on the handset to gai...

Страница 12: ...821110 Technical Helpline 01242 822972 2013 Astor Bannerman Medical Limited Our policy is one of continuous development and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the consent of Astor Bannerman Medical Limited Original Document ...

Отзывы: