Das ASSMANN Prinzip.
Gute Arbeit.
Benutzerinformation
Canvaro STS
Technical data Canvaro.
12
Controlbox CDB4 and CBD6, lift column DL11 – Canvaro
Control and motor system:
LINAK
Adjustment mechanism:
Spindle adjustment in the leg
Synchronization:
Electric synchronization by the electrical control unit
Tube diameter of the lift columns:
70 mm / 63.5 mm / 57 mm (outside / middle / inside)
Temperature range at point of use:
+ 5
°
C to + 40
°
C
Max. relative humidity:
80%
Rated voltage:
230 V AC ~
±
10%
Rated frequency:
50 Hz
Intermittent periodic duty:
max. 2 min / 18 min
Maximum load:
Desk
75 kg
CPU holder
20 kg
Equipment holder
20 kg
Type of protection:
IP 40
Maximum power consumption during lifting operation::
2 lift columns
400 W (CDB4)
3 lift columns
600 W (CDB6)
Power consumption in standby mode:
0,1 W
T
raversing speed:
38 mm/s (without load)
Maximum adjustment range:
600 mm
Control panel up / down:
Standard
Bedienpaneel Memory:
Optional (verkabelt)
Noise level:
max. 48 dB(A)
Rating plates are located on the control system housing, the lift columns and underneath the desktop.