FEATURES 

 

Small, robust and handy. 

 

Choice of manual operation by push buttons or in automatic mode. 

 

Independent of mains power supply. 

 

An in-built safety mechanism prevents demagnetizing when the load is suspended. 

 

The battery (lithium-ion battery) is charged in approx. 3 hours using a mains charger. 

 

Low power consumption. 

6

 

SAFETY INSTRUCTIONS 

 

 

 

 

 

 

 

 

 

Never use the SAFEBAT lifting magnet before these instructions have been read and understood. 

 

Persons having a pacemaker or other medical device should never come closer than 10 cm to the 
SAFEBAT lifting magnet. 

 

Never remove warning or instruction signs from the SAFEBAT lifting magnet. 

 

Always wear safety goggles, gloves, protective boots and helmet. 

 

Never stay or move under the load. 

 

Never move loads over or close to people. 

 

Never use the SAFEBAT lifting magnet for hoisting, supporting or transporting people. 

 

Warn people nearby before beginning to lift the load. 

 

Whenever possible, make use of lifting hooks equipped with a safety lock. 

 

Ensure that the weight and dimensions of the load to be lifted do not exceed the maximum 
permitted values. 

 

Never use a damaged or poorly operating SAFEBAT lifting magnet. 

 

Press the MAG-button only when the lifter has been placed on the load. 

 

Press the DEMAG-button only when the load has been placed on a stable surface. 

 

Never lift more than one load at a time with the SAFEBAT lifting magnet. 

 

Never leave a hoisted load unattended. 

 

The maximum operating temperature must never exceed 80°C. 

 

7

 

FACTORS AFFECTING HOLDING POWER 

7.1

 

MATERIAL 

Содержание SAFEBAT SB200

Страница 1: ...ny 49 0 7171 92505 0 Fax 49 0 7171 92505 50 Operating manual Battery powered Electro permanent Load Lifting Magnet SAFEBAT SB200 SB500 SB950 Type Dimensions LxWxH mm Load kg Load kg Weight kg Item no SB200 150x85x150 200 50 10 65697 SB500 180x160x140 500 200 25 62666 SB950 355x165x170 950 400 41 60643 ...

Страница 2: ...URES 7 6 SAFETY INSTRUCTIONS 7 7 FACTORS AFFECTING HOLDING POWER 7 7 1 MATERIAL 7 7 2 CONTACT AREA 8 7 3 OVERHANG 8 7 4 LOAD THICKNESS 9 7 5 LOAD TEMPERATURE 9 7 6 AIR GAP 9 8 OPERATION 11 8 1 Power ON OFF 11 8 2 Before start up 12 8 3 To Magnetize 12 8 4 To Demagnetize 12 8 5 Automatic mode 13 8 6 Holding force levels 13 8 7 Indications output by the COMMON LED BUZZER regarding ADPREM and battery...

Страница 3: ...is guaranteed for a term of 12 months The guarantee does not cover defects that can be completely or partially attributed to Ignoring the operating and maintenance instructions Improper use Normal wear Modifications or repairs not performed by Assfalg or an authorised agent In all correspondence regarding your SAFEBAT lifting magnet always state the information indicated on the nameplate 2 APPLICA...

Страница 4: ...dle workloads up to 200 kg for flat material and up to 50 kg for round material Using a current pulse of less than one second the Assfalg SB200 can be switched manually using push buttons or in automatic mode While lifting the load no current is required the workpiece remains safely held as by a permanent magnet Up to 600 ON OFF switching cycles are possible before recharging the internal battery ...

Страница 5: ...ial Using a current pulse of less than one second the Assfalg SB500 can be switched manually using push buttons or in automatic mode While lifting the load no current is required the workpiece remains safely held as by a permanent magnet Up to 1 000 ON OFF switching cycles are possible before recharging the internal battery using the supplied mains charger Option Special pole shoes to be fixed on ...

Страница 6: ...rial Using a current pulse of less than one second the Assfalg SB950 can be switched manually using push buttons or in automatic mode While lifting the load no current is required the workpiece remains safely held as by a permanent magnet Up to 500 ON OFF switching cycles are possible before recharging the internal battery using the supplied mains charger Option Special pole shoes to be fixed on t...

Страница 7: ... material 600 kg 7 Weight 10 kg 4 2 SB500 Serial no Type Dimensions 1 Length 180 mm 2 Width 160 mm 3 Height with hoisted D shackle 290 mm 4 Height without D shackle 202 mm 5 Housing height 140 mm 6 Test load with flat material 1500 kg 7 Weight 25 kg 8 Option Special pole shoes 4x M12 on request 4 3 SB950 Serial no Type Dimensions 1 Length 355 mm 2 Width 165 mm 3 Height with hoisted D shackle 365 m...

Страница 8: ...truction signs from the SAFEBAT lifting magnet Always wear safety goggles gloves protective boots and helmet Never stay or move under the load Never move loads over or close to people Never use the SAFEBAT lifting magnet for hoisting supporting or transporting people Warn people nearby before beginning to lift the load Whenever possible make use of lifting hooks equipped with a safety lock Ensure ...

Страница 9: ...els cast iron and stainless steel are characterised by lower magnetic conductivity Generally the holding force can be summed up as the function of carbon Ni Cr content and hardness of the steel 7 2 CONTACT AREA The magnetic holding force depends on the contact area between load and magnet The larger the contact area the higher the lifting capacity of the magnet 7 3 OVERHANG The admissible overhang...

Страница 10: ...ic force steadily diminishes Therefore any load whose temperature has exceeded 80 C should not be hoisted with the lifting magnet Notice Contact with hot loads may cause failure of the lifting magnet With longer contact the magnets are damaged by the penetrating heat 7 6 AIR GAP The air gap is the average distance between the poles of the lifting magnet and load surface Air gaps are caused by fore...

Страница 11: ...info assfalg metal com www assfalg metal com 10 Assfalg GmbH Buchstraße 149 73525 Schwäbisch Gmünd Germany 49 0 7171 92505 0 Fax 49 0 7171 92505 50 ...

Страница 12: ...er sounds briefly and the status of the SAFEBAT is indicated To turn OFF press and hold the COMMON button until all the LEDs light and then release that button The SAFEBAT automatically turns itself OFF after 5 minutes of inactivity ALARM LED Power ON ADPREM BATTERY STATUS LED HOLDING FORCE LEVELS INDICATION MAG LEDs AUTOMATIC MODE AUTO LED DEMAG LED DEMAG BUTTON COMMON BUTTON MAG BUTTON HOLDING F...

Страница 13: ...tizing or demagnetizing make sure that the lifting magnet has been completely lowered and the tension on the crane hook is fully relieved 8 3 To Magnetize The SAFEBAT lifting system has to be lowered The ADPREM LED has to light For magnetizing press the COMMON and MAG buttons at the same time 8 4 To Demagnetize The SAFEBAT lifting system has to be lowered The ADPREM LED has to light For demagnetiz...

Страница 14: ...e press the MAG and DEMAG buttons at the same time The automatic mode indication LED goes off to show that the automatic mode is deactivated In automatic mode the SAFEBAT turns itself automatically OFF after 15 minutes of inactivity 8 6 Holding force levels The SAFEBAT offers three holding force levels By default the level is always pre set at the maximum holding force level 3 The currently select...

Страница 15: ...ange the holding force level first press and hold the MAG button and then the HOLDING FORCE LEVEL button Each time the HOLDING FORCE LEVEL button is pressed the selected level changes as shown by the three green LEDs With level 3 all three green LEDs light With level 2 the left hand and middle green LEDs light With level 1 the left hand green LED lights ...

Страница 16: ...er magnetizing At reduced holding force level 2 the LED 2 flashes slowly after magnetizing At reduced holding force level 1 the LED 1 flashes quickly after magnetizing Example of the effect of the holding force level onto the holding force with 4mm sheet thickness SAFEBAT Lifter 4mm sheet thickness kg tear off force Level 3 Level 2 Level 1 SB200 50 150 33 100 20 60 SB500 100 300 67 200 47 140 SB95...

Страница 17: ... Indicates whether the SAFEBAT is enabled for operation and also the battery status OFF LIFTING MAGNET HOISTED OPERATION DISABLED ON LIFTING MAGNET LOWERED BATTERY OK OPERATION ENABLED SLOWLY FLASHING LIFTING MAGNET LOWERED BATTERY LOW CHARGE SOON OPERATION ENABLED FAST FLASHING BUZZER LIFTING MAGNET LOWERED BATTERY EMPTY CHARGE IMMEDIATELY MAGNETIZATION DISABLED OFF BUZZER LIFTING MAGNET HOISTED ...

Страница 18: ...me before use Clean the magnetic poles as well as the contact surface area of the load Remove burrs Position the lifting magnet on the load prior to starting any operation Press the MAG button to magnetize Lift the load a short distance Inspect its balance Lift or lower the load another time to correct its position Lower the Load Demagnetize The next lifting operation can be initiated now 9 LIFTIN...

Страница 19: ...N LED flashes quickly The battery must be charged immediately In such condition the SAFEBAT can still be demagnetized but not magnetized When the battery voltage falls below its working condition the SAFEBAT turns itself OFF automatically and cannot be turned back ON until the battery has been completely charged It takes appr 3 hours to fully charge the SAFEBAT battery SAFEBAT is equipped with aut...

Страница 20: ...l design provides for good heat dissipation LED display visualizes the charging power from 25 100 Short circuit over current and over temperature protection make the charger safe and reliable Do not place the charger on an unstable cart stand or table If the charger falls it could be damaged Do not disassemble the charger take it to a qualified service technician when service or repair is required...

Страница 21: ...ut then SAFEBAT turns off Battery level is too low 14 2V Charge the battery as described in Charging Instructions If the problem persists then contact Assfalg for a new charger and or battery SAFEBAT will not power up at all Battery may be damaged or have a bad cell Contact Assfalg for a new battery ALARM LED flashes BUZZER sounds intermittently Current did not reach the level required for proper ...

Страница 22: ...Lifting Magnet with Battery SAFEBAT SB200 SB500 SB950 fulfils the safety and health requirements of the following EC guideline Directive 2006 42 EC Machinery Directive The protection objectives of the following provisions and standards are in accordance with 2014 35 EC Low Voltage Directive DIN EN 61000 6 1 Electromagnetic Compatibility EMC Name and address of the person who is authorised to creat...