Assa Abloy Yale Real Living YRL210 Скачать руководство пользователя страница 18

18

An ASSA ABLOY Group brand

P/N AYRT-210-INST-FUL Rev E

Enable

  

Disable

   

     Feature Programming Through Menu Mode Using Master PIN code*

  

1. Enter the 4-8 digit Master PIN code followed by the   key. 
2. Enter digit corresponding to the function to be performed followed by the   key. 

Note: If the lock is connected to a network controller, it is recommended that it is 
programmed through the centralized user interface (PC or hand-held device) to 
ensure communication between the lock and the controller unit. 

1

2

Master Code Registration

M

M

User Number (UN)

 

ƒ

1~25: without network module

 

ƒ

1~250: with network module 

  User PIN Registration

U

For quiet areas, select Disable (3) 

in Audio Mode.

Register

Delete

   

Advanced Lock Settings

Audio Mode

 All Code Lockout

Register

Enable

Enable

Disable

Delete

Disable

**This function appears 

only with RF network 

module installed.

Enable

  

Disable

   

Automatic Re-lock Setting

Inside Indicator Light

One Touch Locking Setting

Enable

  Disable

   

Note: If the lock is connected to a network controller, 

it is recommended that it is programmed through 

the centralized user interface (PC or hand-held 

device) to ensure communication between the lock 

and the controller unit. 

**Network Module Setting

N/A

*

A unique Master PIN Code must be entered prior to any further programming of the lock. 

  (See section on page 16  "Register Master PIN Code Before Programming")

Default settings 
in 

bold

.

Содержание Yale Real Living YRL210

Страница 1: ...m Click Product Information Documentation and then Installation Instructions Este documento est disponible en espa ol en nuestra p gina de internet Vaya a www yalecommercial com Presione Informaci n d...

Страница 2: ...pment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help IMPORTANT...

Страница 3: ...une antenne d un type et un maximum ou moins approuv s pour gagner de l metteur par Industrie Canada Pour r duire le risque d interf rence aux autres utilisateurs le type d antenne et son gain doivent...

Страница 4: ...tcheon Latch 4 Interior Escutcheon Mounting Screws Pack 1 2 Interior Mounting Plate Screws Pack 1 2 Latch 2 Strike Plate Mounting Screws Pack 2 Cylinder Installation Instructions Template Latch Strike...

Страница 5: ...tanding exterior of the door NOTE Both latch face and strike plate have adhesive backed covers to prevent marring and should be removed upon installation IMPORTANT Latch bevel must match door bevel an...

Страница 6: ...M4 x 25 4mm Flat Head Combination Screws Exterior Escutcheon with gasket Exterior of Door Do not remove clip from Exterior Escutcheon shank until correct handing has been determined and Exterior Lever...

Страница 7: ...marked WHITE Tailpiece horizontal Posts are inserted in holes according to backset adjustment Refer to Fig A under Lock Preparation 4 Remove the interior mounting plate with gasket from the back door...

Страница 8: ...terior escutcheon is vertically aligned Tighten securely with a 2 Phillips screwdriver Do not over tighten 6 Holding the exterior escutcheon flush to the door position the interior mounting plate by f...

Страница 9: ...tion indicated by arrows on PCB as in Fig 13 10 Install and secure interior escutcheon to interior mounting plate using 4 M4 x 8mm pan head machine screws through the interior escutcheon into the moun...

Страница 10: ...Correct curved position Incorrect Incorrect Determine Lever Position Both exterior and interior lever handles should always point toward the door hinges Important Note Follow the detailed instructions...

Страница 11: ...exterior escutcheon shank 12 Install hex set screw Install the Exterior Lever Hex Set Screw RH RHR LH LHR Figure 16 CW A Place set screw in hole on side of shank toward latch Fig 16 turn set screw clo...

Страница 12: ...s will retract the set screw back into the lever handle to secure it Do not overtighten 17 Rotate thumbturn counter clockwise to horizontal position Fig 21 Figure 21 Hex Lever Set Screw IMPORTANT Test...

Страница 13: ...Fig 23 This will retract the set screw back into the lever handle to secure it in place Do not overtighten NOTE Thumbturn should still be in horizontal position IMPORTANT Before installing the batteri...

Страница 14: ...cons Used in This Guide Click the indicated number Enter Master PIN code 4 8 digits in length Press the Star key on the keypad to Enter or Accept entry Enter User PIN Can be 4 8 digits in length Press...

Страница 15: ...is setting becomes available through the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch...

Страница 16: ...es no codes are registered and the process must be re started PIN code structure Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes OPERATION Prote...

Страница 17: ...ies are properly installed release the reset button All features including adjustable settings see below should now be returned to factory default Upon reset Master Code Registration is the only optio...

Страница 18: ...k module User PIN Registration U For quiet areas select Disable 3 in Audio Mode Register Delete Advanced Lock Settings Audio Mode All Code Lockout Register Enable Enable Disable Delete Disable This fu...

Страница 19: ...19 An ASSA ABLOY Group brand P N AYRT 210 INST FUL Rev E Open Door with PIN Code 1 Enter PIN code 2 Complete the code entry by pressing the key Unlock 3...

Страница 20: ...f latch and or strike plate which may be preventing latch from properly entering the strike plate With the door open extend and retract the latch if it is smooth check the strike plate alignment Latch...

Страница 21: ...ock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes will not register PIN codes must consist of 4 to 8 digits to register The same PIN code can...

Страница 22: ...p 7 page 18 for enrollment of the Network Module 1 Remove cylinder A Repeat previous steps for removing the exterior lever handle B Remove cylinder Replace Install Cylinder 2 Install new cylinder A In...

Страница 23: ...___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User _...

Страница 24: ...roup company is prohibited YALE with its unique global reach and range of products is the world s favorite lock the preferred solution for securing your home family and personal belongings ASSA ABLOY...

Отзывы: