15
An ASSA ABLOY Group brand
P/N AYRT-210-INST-FUL Rev E
All Code Lockout Mode
: This feature is enabled by the Master code. When enabled, it restricts
all user (except Master)PIN code access. When attempting to enter a code while the unit is in
Lockout, the Status Indicator flashes RED and BLUE (8 times); the keypad flashes as well.
Audio Mode
: Choosing
Disable (3)
in Audio mode shuts off the code confirmation tone play-
back for use in quiet areas. Audio mode is enabled or disabled through feature programming by
the Master PIN code.
Automatic Re-lock Time
: After successful code entry and the unit unlocks, it will automatically
re-lock after a default of thirty (30) seconds. Re-lock time is adjustable* from 10 - 180 seconds.
Inside Indicator Light
: Shows active status (Locked) of lock and can be enabled or disabled in
the
Advanced Lock Settings
(Main Menu selection #3).
Low Battery
: When battery power is low, the Status Indicator flashes RED. If battery power is
completely lost, use the key override.
Master PIN Code
: The Master PIN code is used for programming and for feature settings.
It
must be registered prior to programming the lock.
The Master code will also operate
(unlock/lock) the lock.
Network Module Setting:
With the optional Network Module installed, this setting becomes
available through the Main Menu (7) and allows the lock to connect with a network controller.
One Touch Locking:
When the latch is retracted, activating the keypad will extend the
latch (during Automatic Re-lock duration or when Automatic Re-lock is disabled).
Privacy Mode Button:
Pressing and holding the Privacy button (found below thumbturn) for a
duration of four beeps deactivates the keypad, and because it is set from the inside, provides a
secure lock for the convenience of the occupant(s).
Shutdown Time
: The unit will shutdown for a default of sixty (60) seconds (time is adjustable*
from 10 - 180 seconds) and not allow operation after the wrong code entry limit (see below)
has been met. When the unit is in Shutdown, the Status Indicator flashes RED and BLUE; the
keypad flashes as well.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code
: The User code operates the lock. Maximum number of user codes is 250 with
Network Module; without Network Module, maximum is 25 user codes.
Wrong Code Entry Limit
: After a specified number of unsuccessful attempts at entering a valid
PIN code the unit will shut down and not allow operation. Default setting is (5). Limit is adjust-
able* from one (1) to ten (10) times.
Definitions
Low Battery Warning
1
Lock-out Mode
2
Enter the Menu Mode
3
Status Indicators
RED
RED &
BLUE
BLUE
*Adjustable only when using Network Module with compatible integrated controller