5
1-800-727-5477 • www.sargentlock.com
7800 and 8200 Series Mortise Lock
Installation Instructions
Used with Sectional Trim and V Series Indicators
Copyright © 2019, 2020, 2021, 2022, SARGENT Manufacturing Company. All rights reserved. Reproduction in
whole or in part without the express written permission of SARGENT Manufacturing Company is prohibited. Patent
pending and/or patent www.assaabloydss.com/patents.
A8257E 4/22
Installation, continued
5
d
Install Levers
Inside of door
Inside Lever
Rose
Adapter
Plate
Spindle
#8-32 x
5/8" screws
Outside of door
RH door
shown
Figure 8
Set screw
Outside
lever & Rose
Assembly
#6 x 3/8"
screws
Mounting
Plate
Figure 9
Figure 10
e
Install Indicator Mounting Plate
1. Slide outside lever and rose assembly through door and lock
body, and hold. (Figure 8)
2. Slide inside spindle into lock body hub.
3. Slide adapter and plate assembly over spindle.
4. Secure with two (2) #8-32 x 5/8" screws.
5. Install inside rose onto adapter plate.
6. Install inside lever on adapter plate. Secure with set screw.
1. Screw indicator mounting plate to door with four (4) #6 x 3/8"
sheet metal screws. (Figure 9)
2. If indicators are being used on both sides of door, repeat step 1
for opposite side.
f
Install Indicator Assembly
1. Verify lock is in unlocked state (turn outside lever to confirm).
2. Verify indicator is in vacant/unlocked position.
3. Assemble indicator assembly onto mounting plate. (Figure 10)
4. Secure indicator assembly to door with two (2) machine
screws.
• Use #8-32 x 5/8
"
screw for top
• Use #8-32 x 3/8
"
screw for bottom
5. If indicators are being used on both sides of door, repeat steps 1
through 3 for opposite side.
Note:
Torx security screws recommended.