Programming Instructions
The Keypad Exit Device Lock can support 100 users. Each user is assigned a User Number
in addition to the code used for entry.
Example:
This Keypad Exit Device Lock has 99 User Codes available for programming purposes.
• The Master Code is
always
User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used
for programming. Users are deleted through the Master Programming Code only.
• The Emergency Code is
always
User “02”. The Emergency Code will override the deadbolt in the mortise lock and has
an unlock time of 10 seconds.
• The Supervisory Code is
always
User “03”. The Supervisory Code allows temporary lockout of selected users, changes
duration of unlock time, requests infrared interrogation output, and may add additional User Codes.
• The first User Code will be User “04” or higher. User numbers do not have to be used or entered sequentially.
• User codes “98” and “99” have a factory-set unlock time of ten seconds. This allows a handicapped person extra time
which would not be required by other users.
To Begin Programming:
The Keypad Exit Device Lock is preset at the factory with Master Code “1234”.
Entering 1234* the lever handle to retract the latchbolt.
Initial Set-Up Procedures:
• The following are typical procedures to follow when setting up your KP Exit Series Keypad.
• If a mistake is made during any of procedures, depress the
several times until the yellow LED goes out.
• If no keystroke is made in a 30sec time frame the programming up to that point will default and you will have to start over.
• If after the last “
*
” is depressed, the yellow LED does not go out, depress “
*
” once more.
Change the Master Code:
99# 1234
50# 1# 01# New Master Code
*
New Master Code
This example uses the Factory Default Master Code
*
*
*
To Enter the Emergency Code:
99# Master Code
50# 1# 02# Emergency Code
*
Emergency Code
*
*
*
Yellow LED begins to blink slowly
Yellow LED blinks quickly
Yellow LED blinks slowly
Yellow LED goes out
Yellow LED begins to blink slowly
Yellow LED blinks quickly
Yellow LED blinks slowly
Yellow LED goes out
USER
TYPE
USER
NUMBER
USER CODE
(2-6 DIGITS)
Master
Emergency
Supervisor
01
02
03
1 2 3 4
2 2 2 2 2
3 0 3 0 3 0
Standard
04-97
2 6 5
Special Factory
10 Sec. Time Preset
98
99
1 3 6 8
“
*
”
19