24 1-800-810-WIRE • www.sargentlock.com • A8151H
Copyright © 2016, 2019, 2021, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/30/21
IN120 / IN220 Mortise Lock
Important Note: Before you install the controller
1. Insert bottom tab of controller (ensure a clear path) into slot on mounting plate (Fig. 11D, E).
2. Ensure proper alignment of board-to-board connectors (Fig. 11E) while pivoting controller toward door
until two tabs on top click securely into place on mounting plate (Fig. 11D).
CAUTION
: To avoid possible damage to board-to-board connectors, care should be taken when securing controller
to mounting plate. If there is resistance when securing, detach controller to determine cause before
re-attaching controller.
Fig. 11D
12 Supplying Power to the Controller
1. Once controller is securely in place, connect PoE
plug (RJ45 male) to female RJ45 port on controller
board (Fig. 12A).
2. If power is enabled, LED will flash and lock motor
will cycle.
Important - before inserting PoE plug into PoE connector, apply
dielectric grease to top of plug, covering the pin area (Fig. 12A).
Fig. 12A
A. IN220 (PoE)
11 Installing the Controller (Continued)
Fig. 11E
Click
into
place
Fig. 11E