Prepare Door

b

Install Lock

Installation

5

Figure 6 

 

Prepare door for function holes, size, and location  according to A8258 door 
marker template, if not already prepped.

1.  Verify strike location according to template. Clean out door pocket and door edge of debris.

2.  Ensure handing of lock matches handing of door.  Slide lock into door. (Figure 6)

3.  Temporarily hand tighten two (2) lock screws  (#12 x 1-1/4

"

 wood screws, or #12-24 x1/2

"

 machine screws).

Notes:

•  Keep door open until installation is complete.

c

Install Outside Trim

d

Install Inside Trim

Inside of door

Lock

Lock 
Screws

Outside 
of door

RH door
shown

1.  Verify lock is in unlocked state (control hub slot should be vertical). 

Also, verify indicator is in 

v

acant/unlocked position.

2.  Align trim posts with diagonal holes in door, be sure lever is horizontal. Slide outside 

escutcheon assembly through lock body from outside door face. (Figure 7)

Note:

If indicator is used on outside, align indicator spindle with control hub. 

Outside Escutcheon Assembly

Figure 7 

  

1.  Slide spindle into lockbody hub. (Figure 8)

2.  Slide adapter and plate assembly over spindle. 

3.  Secure with two (2) #8-32 x 5/8" screws.

4.  For Studio Collection levers only, use trim bushing over adapter plate.

5.  Verify lock is in unlocked state (turn outside lever to ensure).

Also, Verify indicator is in vacant/unlocked position.

6.  Align escutcheon over adapter and install inside  escutcheon assembly onto 

inside door face.

Note:

• 

 If indicator is used on inside, align indicator  spindle with control hub.

7.  Through-bolt inside escutcheon to outside escutcheon with                           

two (2) #8-32 x 2-1/4

"

 screws. 

8.  Install inside lever on adapter plate. Secure with set screw.

Note: 

Screw heads should be visible on inside escutcheon.

Figure 8 

 

Inside 
Escutcheon 
Assembly

Studio 
Collection 
Trim 
Bushing

Adapter Plate

Spindle

Lever

Set 
screw

#8-32 x 2-1/4" screw

#8-32 x 
2-1/4" 
screw

#8-32 x 
5/8" screws

Содержание Sargent 7800 Series

Страница 1: ...part without the express written permission of SARGENT Manufacturing Company is prohibited Patent pending and or patent www assaabloydss com patents WARNING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov Attention Installer Improper installation may result i...

Страница 2: ...y is prohibited Patent pending and or patent www assaabloydss com patents Tools Required 1 TOC Table of Contents 1 Tools Required 2 2 Indicator Variants 3 3 Lock set configuration 3 4 Rehanding Indicator if required 3 5 Installation 4 a Prepare Door 4 b Install Lock 4 c Install Outside Trim 4 d Install Inside Trim 4 e Install Cylinder 5 f Install Outside Front 5 g Perform Functional Check 5 h Indi...

Страница 3: ...LH Left Hand Hinges Left Open Inward RH Right Hand Hinges Right Open Inward LHRB Left Hand Reverse Bevel Hinges Left Open Outward RHRB Right Hand Reverse Bevel Hinges Right Open Outward Figure 2 Note Stand on outside of locked door when determining door hand Next verify inside and or outside indicators are handed correctly using Spindle Cam Position chart Figure 3 If they are handed correctly skip...

Страница 4: ... unlocked state control hub slot should be vertical Also verify indicator is in vacant unlocked position 2 Align trim posts with diagonal holes in door be sure lever is horizontal Slide outside escutcheon assembly through lock body from outside door face Figure 7 Note If indicator is used on outside align indicator spindle with control hub Outside Escutcheon Assembly Figure 7 1 Slide spindle into ...

Страница 5: ...re or Interchangeable Core cylinders require a control key key stamped with C to remove and install the core This is not provided standard it must be requested separately If requesting 1 bitted control key specify 113511 cut Cylinder Cylinder Clamp Screw Figure 9 Incorrect Key and cylinder must be rotated as shown Correct Figure 10 1 Tighten the two 2 lock screws completely Figure 11 2 Attach outs...

Страница 6: ...ure 12 Figure 12 Description Part Number Req 1 VN1 Indicator Escutcheon Consult Factory 1 2 Indicator Window 81 0811 1 3 Indicator Display Assembly Green Unlocked Red Locked 82 5602 1 Indicator Display Assembly Green Vacant Red Occupied 82 5603 Indicator Display Assembly Green Unlocked Icon Red Locked Icon 82 5604 Indicator Display Assembly White Unlocked Red Locked 82 5605 Indicator Display Assem...

Страница 7: ...VN1 Escutcheon Trim and V Series Indicators Copyright 2019 2020 2021 SARGENT Manufacturing Company All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing Company is prohibited Patent pending and or patent www assaabloydss com patents A8260D 11 21 ...

Страница 8: ...ING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov A8260D 11 21 ...

Отзывы: